Polymeric coating of surface modified nitinol stent with POSS-nanocomposite polymer
Source abstract
Abstract
Stent angioplasty is a successful treatment for arterial occlusion, particularly in coronary artery disease. The clinical communities were enthusiastic about the use of drug-eluting stents; however, these stents have a tendency to be a contributory factor towards late stage thrombosis, leading to mortality in a significant number of patients per year. This work presents an innovative approach in self-expanding coronary stents preparation. We developed a new nanocomposite polymer based on polyhedral oligomeric silsesquioxanes (POSS) and poly(carbonate-urea)urethane (PCU), which is an antithrombogenic and a non-biodegradable polymer with in situ endothelialization properties. The aim of this work is to coat a NiTi stent alloy with POSS-PCU. In prolonged applications in the human body, the corrosion of the NiTi alloy can result in the release of deleterious ions which leads to unwanted biological reactions. Coating the nitinol (NiTi) surface with POSS-PCU can enhance surface resistance and improve biocompatibility. Electrohydrodynamic spraying was used as the polymer deposition process and thus a few experiments were carried out to compare this process with casting. Prior to deposition the NiTi has been surface modified. The peel strength of the deposit was studied before and after degradation of the coating. It is shown that the surface modification enhances the peel strength by 300%. It is also indicated how the adhesion strength of the POSS-PCU coating changes post-exposure to physiological solutions comprised of hydrolytic, oxidative, peroxidative and biological media. This part of the study shows that the modified NiTi presents far greater resistance to decay in peel strength compared to the non-modified NiTi.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Silicone and Siloxane Chemistry · Metal and Thin Film Mechanics · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (63)
Show source-provided references
1. Assessing the biocompatibility of NiTi shape memory alloys used for medical applications10.1007/s00216-004-2888-3 ↗
2. Surface, corrosion and biocompatibility aspects of Nitinol as an implant material
3. Surface modification of NiTi alloy and human platelet activation under static and flow conditions10.1016/j.matlet.2007.01.032 ↗
4. A meta-analysis of clinical trials of paclitaxel- and sirolimus-eluting stents in patients with obstructive coronary artery disease10.1111/j.1365-2125.2005.02258.x ↗
5. Appropriate use of drug-eluting stents: balancing the reduction in restenosis with the concern of late thrombosis10.1016/S0140-6736(08)60922-8 ↗
6. Nanomedicine for the reduction of the thrombogenicity of stent coatings
7. Severe endothelial dysfunction after sirolimus-eluting stent implantation10.1161/CIRCULATIONAHA.105.597948 ↗
8. Drug-eluting stents and late stent thrombosis10.1016/S0140-6736(07)61424-X ↗
9. In-stent stenosis: pathology and implications for the development of drug eluting stents10.1136/heart.89.2.218 ↗
10. Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents10.1161/CIRCULATIONAHA.104.508937 ↗
11. Particle debris from a nanoporous stent coating obscures potential antiproliferative effects of tacrolimus-eluting stents in a porcine model of restenosis10.1002/ccd.20213 ↗
12. Corrosion resistance of polyurethane-coated nitinol cardiovascular stents10.1163/156856203322599699 ↗
13. Structural evaluation of radially expandable cardiovascular stents encased in a polyurethane film10.1002/jbm.b.30359 ↗
14. Small caliber vascular grafts. Part II. Polyurethanes revisited10.1177/088532829601100102 ↗
15. In vitro stability of a novel compliant poly(carbonate-urea)urethane to oxidative and hydrolytic stress10.1002/jbm.1234 ↗
16. In vivo biostability of a poly(carbonate-urea)urethane graft10.1016/S0142-9612(02)00608-7 ↗
17. The degradative resistance of polyhedral oligomeric silsesquioxane nanocore integrated polyurethanes: an in vitro study10.1016/j.biomaterials.2005.10.006 ↗
18. The antithrombogenic potential of a polyhedral oligomeric silsesquioxane (POSS) nanocomposite10.1021/bm050590z ↗
19. Assessment of the potential of progenitor stem cells extracted from human peripheral blood for seeding a novel vascular graft material10.1111/j.1365-2184.2008.00523.x ↗
20. In situ endothelialization potential of a biofunctionalised nanocomposite biomaterial-based small diameter bypass graft
21. The endothelialization of polyhedral oligomeric silsesquioxane nanocomposites: an in vitro study10.1385/CBB:45:2:129 ↗
22. R. Bakhshi, M.J. Edirisinghe, A. Darbyshire, Z. Ahmad, A.M. Seifalian, Electrohydrodynamic jetting behaviour of polyhedral oligomeric silsesquioxane nanocomposite. Journal of Biomaterials Applications (2008) [Epub ahead of print].10.1177/0885328208089125 ↗
23. Novel electrohydrodynamic printing of nanocomposite biopolymer scaffolds10.1177/0883911507078268 ↗
24. X-ray photoelectron emission microscopy and time-of-flight secondary ion mass spectrometry analysis of ultrathin fluoropolymer coatings for stent applications10.1021/la8002788 ↗
25. Computational investigation of the delamination of polymer coatings during stent deployment10.1007/s10439-010-9972-y ↗
26. Relation of stent design and stent surface material to subsequent in-stent intimal hyperplasia in coronary arteries determined by intravascular ultrasound10.1016/S0002-9149(02)02347-0 ↗
27. Surface treatment of titanium for adhesive bonding to polymer composites: a review10.1016/S0143-7496(00)00044-0 ↗
28. Food and Drug Administration, Guidance for industry and FDA staff, non-clinical tests and recommended labeling for intravascular stents and associated delivery systems. http://www fda gov/cdrh/ode/guidance/1545 html, 2005.
29. In vitro and in vivo performance of a dual drug-eluting stent (DDES)10.1016/j.biomaterials.2010.01.147 ↗
30. Poly(ethylene carbonate): a thermoelastic and biodegradable biomaterial for drug eluting stent coatings?10.1016/j.jconrel.2006.11.003 ↗
31. Evaluation of drug-eluting stents’ coating durability – clinical and regulatory implications10.1002/jbm.b.31420 ↗
32. Coating of poly(p-xylylene) by PLA-PEO-PLA triblock copolymers with excellent polymer–polymer adhesion for stent applications10.1021/bm050642k ↗
33. Observation of the failure mechanism for diamond-like carbon film on stainless steel under tensile loading10.1016/j.scriptamat.2007.07.042 ↗
34. H. Salacinski, S. Hancook, A.M. Seifalian, inventors, Polymer for use in conduits, medical devices and biomedical surface modification, patent Int. App. PCT/GB2005/000489, 2005, 2005.
35. Nature of oxide layer formed on NiTi by anodic oxidation in methanol10.1016/j.matlet.2005.01.013 ↗
36. Hydrolysis, adsorption, and dynamics of silane coupling agents on silica surfaces10.1163/156856191X00611 ↗
37. ASTM D413-98(2007) Standard test methods for rubber property-adhesion to flexible substrate, 2009.
38. New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility10.1002/jbm.b.30441 ↗
39. Critical overview of Nitinol surfaces and their modifications for medical applications10.1016/j.actbio.2008.01.013 ↗
40. Overview: the potential of silanes for chromate replacement in metal finishing industries10.1007/s11201-005-4407-6 ↗
41. Methods for producing adhesive bonds between substrate and polymer employing an intermediate oxide layer, inventors patent United States Patent 4364731, 1982, 1982.
42. Adhesion & bonding: silanes as primers and adhesion promoters for metal substrates10.1016/S0026-0576(07)80186-3 ↗
43. Silane based pretreatments for automotive steels10.1179/026708400101517305 ↗
44. In vitro biocompatibility of titanium–nickel alloy with titanium oxide film by H2O2 oxidation10.1016/S1003-6326(07)60132-0 ↗
45. Formation of titanium oxide coatings on NiTi shape memory alloys by selective oxidation10.1016/j.msea.2007.02.151 ↗
46. A study on the electrodeposition of tantalum on NiTi alloy in an ionic liquid and corrosion behaviour of the coated alloy10.1016/j.elecom.2005.06.007 ↗
47. Effect of surface-treatment on the dissolution of titanium-based implant materials10.1016/0142-9612(91)90144-Y ↗
48. The effect of ageing treatment on shape-setting and superelasticity of a nitinol stent10.1016/j.matchar.2007.02.007 ↗
49. Covalent immobilisation of tropoelastin on a plasma deposited interface for enhancement of endothelialisation on metal surfaces10.1016/j.biomaterials.2008.11.009 ↗
50. In vitro and in vivo changes to PLGA/sirolimus coating on drug eluting stents10.1016/j.biomaterials.2010.02.003 ↗
51. Poly(methyl methacrylate) grafting onto stainless steel surfaces: application to drug-eluting stents10.1021/am900465t ↗
52. Characterization of the inflammatory response to biomaterials using a rodent air pouch model10.1002/(SICI)1097-4636(20000605)50:3<365::AID-JBM10>3.0.CO;2-X ↗
53. In vivo imaging of hydrogen peroxide with chemiluminescent nanoparticles10.1038/nmat1983 ↗
54. Poly(ethylene carbonate): a thermoelastic and biodegradable biomaterial for drug eluting stent coatings?10.1016/j.jconrel.2006.11.003 ↗
55. Influence of external stress on the in vitro degradation behavior of C3D/PLA composites
56. The behavior of vascular smooth muscle cells and platelets onto epigallocatechin gallate-releasing poly(l-lactide-co-epsilon-caprolactone) as stent-coating materials10.1016/j.biomaterials.2007.10.052 ↗
57. Coating of poly(p-xylylene) by PLA-PEO-PLA triblock copolymers with excellent polymer-polymer adhesion for stent applications10.1021/bm050642k ↗
58. Controlled release from multilayer silk biomaterial coatings to modulate vascular cell responses10.1016/j.biomaterials.2007.10.055 ↗
59. Paclitaxel releasing films consisting of poly(vinyl alcohol)-graft-poly(lactide-co-glycolide) and their potential as biodegradable stent coatings10.1016/j.jconrel.2005.12.012 ↗
60. Corroded nitinol wires in explanted aortic endografts: an important mechanism of failure?
61. Biocompatibility testing of NiTi screws using immunohistochemistry on sections containing metallic implants10.1002/(SICI)1097-4636(199610)32:2<243::AID-JBM14>3.0.CO;2-K ↗
62. A novel electrochemical strategy for improving blood compatibility of titanium-based biomaterials10.1016/j.colsurfb.2010.04.013 ↗
63. Simple surface modification of a titanium alloy with silanated zwitterionic phosphorylcholine or sulfobetaine modifiers to reduce thrombogenicity10.1016/j.colsurfb.2010.04.018 ↗