Factors affecting the measurement of photochromic lens performance
Source abstract
Abstract
The principles, characteristics, and measurement methodology of photochromism of plastic ophthalmic lenses are briefly introduced and discussed. The factors influencing measurement variation and accuracy, including the preconditioning process, measurement device, and procedure, were investigated on ophthalmic photochromic lenses covering both photocasting and photocoating lens technologies. By design of experiment, factors affecting the measurements were studied using a photochromic measurement rig with reference to ISO 8980‐3 requirements. Experimental results prove the necessity for a lens preconditioning process prior to measurement. The excitation light source in the photochromic measurement rig has the greatest impact on measurement variation from the device perspective, while lens temperature is the key environmental factor. On the basis of the investigation, recommendations are made for reducing measurement variations and improving result accuracy.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Photochromic and Fluorescence Chemistry · Photoreceptor and optogenetics research · Image Enhancement Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Carl Zeiss Vision Technical Services (Guangzhou) Ltd Guangzhou 510555 China
China National Inspection and Testing Centre for Ophthalmic Optic Glass and Enamel Products Shanghai 201620 China
References (17)
Show source-provided references
1. 10.1351/pac19966807139510.1351/pac199668071395 ↗
2. 10.1111/j.1478-4408.2010.00242.x10.1111/j.1478-4408.2010.00242.x ↗
3. 10.1021/cr980073p10.1021/cr980073p ↗
4. 10.1021/cr980071510.1021/cr9800715 ↗
5. R JAraujo R AEpplerandE FKrause US3328182(1967).
6. 10.1016/j.dyepig.2015.03.01910.1016/j.dyepig.2015.03.019 ↗
7. FChen US8576471(2013).
8. TSakagami KMachida YFujii NArakawaandNMurayama US4756973(1988).
9. LLe Naour‐Sene US4286957(1981).
10. 10.1364/OL.39.00204010.1364/OL.39.002040 ↗
11. 10.1007/s12221-012-1179-410.1007/s12221-012-1179-4 ↗
12. SKadowaki US6913357(2005).
13. KTamura SMitsuuchi KWadaandATakata US20140036227(2014).
14. 10.1016/j.dyepig.2012.12.02110.1016/j.dyepig.2012.12.021 ↗
15. ISO 8980‐3:2013 Ophthalmic optics: Uncut finished spectacle lenses. Part 3: Transmittance specifications and test methods(Basel:ISO 2013).
16. 10.1364/AO.51.00013310.1364/AO.51.000133 ↗
17. Crano J C · 1999