journal article·2024-06

Basic Parameters of Detonation of Hydrogen Mixtures. Part II

A. A. Vasil’ev, V. A. Vasiliev

Publisher page

Abstract

Abstract A large pool of data on the detonation hazard of hydrogen in mixtures with oxygen and air additionally diluted by inert gases and in the presence of steam in the mixture are reported. The most important parameter is the critical energy of detonation initiation, which serves as a measure of the explosion hazard of combustible systems: the smaller the critical energy, the more hazardous the mixture. The number of correct measurements of the critical energy of detonation initiation in scientific publications is rather limited (which is even more true for waves with different symmetries).
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Combustion and Detonation Processes · Energetic Materials and Combustion · Risk and Safety Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (13)

Show source-provided references
1. A. A. Vasil’ev and V. A. Vasiliev, “Basic Parameters of Detonation of Hydrogen Mixtures. Part I," Fiz. Goreniya Vzryva 60 (3), 76–90 (2024) [Combust., Expl., Shock Waves 60 (3), 347–360 (2024); DOI: 10.1134/S0010508224030080].10.1134/S0010508224030080 ↗
2. A. Vasil’ev, “Dynamic Parameters of Detonation," in Shock Waves Science and Technology Reference Library, Ed. by F. Zhang, Vol. 6: Detonation Dynamics (Springer-Verlag, Berlin–Heidelberg, 2012), pp. 213–279.10.1007/978-3-642-22967-1_4 ↗
3. Y. K. Lui, J. H. Lee, and R. Knystautas, “Effect of Geometry on the Transmission of Detonation through an Orifice," Combust. Flame 56 (2), 215–225 (1984); DOI: 10.1016/0010-2180(84)90038-5.10.1016/0010-2180(84)90038-5 ↗
4. J. H. Lee, R. Knystautas, and C. Guirao, “The Link between Cell Size, Critical Tube Diameter, Initiation Energy and Detonability Limits," in Fuel–Air Explosions (Univ. of Waterloo Press, 1982), pp. 157–187.
5. D. C. Bull, J. E. Elsworth, P. J. Shuff, and E. Metcalfe, “Detonation Cell Structures in Fuel–Air Mixtures," Combust. Flame 45, 7–22 (1982); DOI: 10.1016/0010-2180(82)90028-1.10.1016/0010-2180(82)90028-1 ↗
6. A. A. Vasil’ev, M. E. Topchiyan, and V. Yu. Ul’yanitskii, “Effect of Initial Temperature on Gas-Detonation Parameters," Fiz. Goreniya Vzryva 15 (6), 149–152 (1979) [Combust., Expl., Shock Waves 15 (6), 815–817 (1979)].10.1007/BF00739878 ↗
7. C. K. Westbrook and P. A. Urtiew, “Chemical Kinetic Prediction of Critical Parameters in Gaseous Detonations," Symp. (Int.) Combust. 19 (1), 615–623 (1982); DOI: 10.1016/S0082-0784(82)80236-1.10.1016/S0082-0784(82)80236-1 ↗
8. J. E. Shepherd, “Chemical Kinetics of Hydrogen–Air-Diluent Detonations," in Dynamics of Explosion, Ed. by J. Bowen and J. Leyer (1986), pp. 263–293; DOI: 10.2514/5.9781600865800.0263.0293.10.2514/5.9781600865800.0263.0293 ↗
9. S. R. Tieszen, M. P. Sherman, W. B. Benedick, et al., “Detonation Cell Size Measurements in Hydrogen–Air–Steam Mixtures," in Dynamics of Explosion, Ed. by J.-C. Leyer, R. Soloukhin, and J. Bowen (Am. Inst. of Aeronaut. and Astronaut.,1986), pp. 205–219; DOI: 10.2514/5.9781600865800.0205.0219.10.2514/5.9781600865800.0205.0219 ↗
10. R. K. Kumar, “Detonation Cell widths in Hydrogen–Oxygen–Diluent Mixtures," Combust. Flame 80 (2), 157–169 (1990); DOI: 10.1016/0010-2180(90)90124-A.10.1016/0010-2180(90)90124-A ↗
11. D. W. Stamps and S. R. Tieszen, “The Influence of Initial Pressure and Temperature on Hydrogen–Air–Diluent Detonations," Combust. Flame 83 (3/4), 353–364 (1991); DOI: 10.1016/0010-2180(91)90082-M.10.1016/0010-2180(91)90082-M ↗
12. S. R. Tieszen, D. W. Stamps, C. K. Westbrook, and W. J. Pitz, “Gaseous Hydrocarbon–Air Detonations," Combust. Flame 84 (3/4), 376–390 (1991); DOI: 10.1016/0010-2180(91)90013-2.10.1016/0010-2180(91)90013-2 ↗
13. C. Ciccarelli, T. Ginsberg, J. Boccio, et al., “Detonation Cell Size Measurements and Predictions in Hydrogen–Air–Steam Mixtures at Elevated Temperatures," Combust. Flame 99 (2), 212–220 (1994); DOI: 10.1016/0010-2180(94)90124-4.10.1016/0010-2180(94)90124-4 ↗