Thermal analysis of initiator systems for high-temperature-cure composites☆
Source abstract
Abstract
The use of multi-component initiator systems is becoming a common practice in the processing of high-temperature-cure composites. Understanding the effects of various initiators on cure behaviour of the resin is essential to optimise performance of the composite. Cure characteristics of resins initiated with multi-component peroxide initiators have been studied using temperature modulated differential scanning calorimetry. The effects of various initiators on exotherm onset and peak temperatures and glass transition temperature have been determined.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Epoxy Resin Curing Processes · Photopolymerization techniques and applications · Additive Manufacturing and 3D Printing Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. Douglass · 1994
2. Influence of catalyst and reaction exotherm on the cure of unsaturated polyester and vinyl ester laminates
3. A kinetic study of the effect of three catalytic systems on the curing of an unsaturated polyester resin10.1002/app.1994.070510308 ↗
4. Theoretical and experimental conversion in the curing of unsaturated polyester resins with styrene as a crosslinking agent10.1002/app.1992.070450203 ↗
5. Bitler · 1997
6. Milleville · 1990
7. Glass transition temperature profile of the curing reaction of unsaturated polyester resin10.1295/polymj.28.965 ↗
8. Chachad · 1993
9. Curing simulation of thermoset composites10.1016/S1359-835X(99)00032-9 ↗
10. Modulated differential scanning calorimetry: non-isothermal cure, vitrification, and devitrification of thermosetting systems10.1016/0040-6031(96)03005-5 ↗
11. Modulated temperature differential scanning calorimetry: characterization of curing systems by TTT and CHT diagrams10.1007/BF01987467 ↗
12. The characterization of thermoset cure behavior by differential scanning calorimetry. Part 1: Isothermal and dynamic dtudy10.1002/pc.750080609 ↗
13. Bladergroen · 1988
14. Modulated DSC evaluation of isothermal cure and vitrification for thermosetting systems10.1016/0040-6031(95)02693-2 ↗
15. Non isothermal heat capacities and chemical reactions using a modulated DSC10.1007/BF01983608 ↗
16. Modulated differential scanning calorimetry: isothermal cure and vitrification of thermosetting systems10.1016/0040-6031(95)02693-2 ↗