Abstract A full-scale experiment was conducted to investigate the composite behavior of insulated concrete sandwich wall panels (ICSWPs) under monotonic loads and wind-induced cyclic loads. The experimental program consists of two groups, according to the applied loading type and the type of insulation, with the same configurations of glass-fiber-reinforced polymer (GFRP) grids. The degree of composite action in terms of the initial stiffness and ultimate strength were compared at the global level, and the degree of composite action in terms of the shear flow were compared at the local level (in accordance with the variables). The test results showed that the adhesive bonds based on the insulation absorptiveness and the mechanical bonds based on the insulation surface roughness and groove treatment were effective for inducing the desired composite behavior of ICSWPs in both monotonic loading and cyclic loading tests. The cyclic test group showed a lower degree of composite action compared to the monotonic test group at a constant rate. This is the case because cumulative fatigue loading damaged the GFRP strands and debonded the interface between the concrete and insulation. These results indicated that the adhesive and mechanical bonds between the insulation and concrete wythes can be used to estimate the design strength of ICSWPs with GFRP shear grids. Additionally, the reduction factor for the design strength by the fatigue effect should be considered in estimation of design strength.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Masonry and Concrete Structural Analysis · Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. Agency IE · 2013 · 68
2. In-plane shear behavior of insulated precast concrete sandwich panels reinforced with corrugated GFRP shear connectors10.1016/j.compositesb.2015.04.056 ↗
3. Effect of GFRP shear ties on shear behavior of interfaces between precast concrete panel and extruded polystyrene special insulation10.4028/www.scientific.net/AMR.658.46 ↗
4. Flexural behavior of composite precast concrete sandwich panels with continuous truss connectors10.15554/pcij.03011994.112.121 ↗
5. Thermo-mechanical loading of GFRP reinforced thin concrete panels10.1016/j.compositesb.2015.06.020 ↗
6. Test on pultruded GFRP I-section under web crippling10.1016/j.compositesb.2015.03.026 ↗
7. A new structurally and thermally efficient precast sandwich panel system10.15554/pcij.07011994.90.101 ↗
8. Full scale testing of precast concrete sandwich panels
9. Behavior of precast, prestressed concrete sandwich wall panels reinforced with CFRP shear grid10.15554/pcij.03012011.42.54 ↗
10. Optimized NU sandwich panel system for energy, composite action and production efficiency
11. Experimental investigations on textile-reinforced concrete (TRC) sandwich sections10.1016/j.compstruct.2014.07.056 ↗
12. Performance and characterization of shear ties for use in insulated precast concrete sandwich wall panels10.1061/(ASCE)ST.1943-541X.0000430 ↗
13. Reliability-based flexural design models for concrete sandwich wall panels with continuous GFRP shear connectors10.1016/j.compositesb.2015.11.040 ↗
14. Composite and non-composite behaviors of foam-insulated concrete sandwich panels10.1016/j.compositesb.2014.08.034 ↗
15. State-of-the-art of precast/prestressed sandwich wall panels
16. A comparative study of various FRP shear connectors for sandwich concrete walls
17. Experimental investigation of precast concrete insulated sandwich panels with glass fiber-reinforced polymer shear connectors10.14359/51686621 ↗
18. Effects of insulation types on in-plane shear behavior of insulated concrete sandwich wall panels with GFRP shear connector10.12988/ces.2015.516 ↗
19. Structural behavior of insulated prestressed concrete sandwich panels reinforced with FRP grid
20. Use of FRP grid for the composite action of concrete sandwich panels
21. Composite behavior of a novel insulated concrete sandwich wall panel reinforced with GFRP shear grids: effects of insulation types10.3390/ma8030899 ↗
22. Insulation type effect on the direct shear behavior of concrete sandwich panel (CSP) with non-shear connectors10.4028/www.scientific.net/AMR.663.154 ↗
23. Composite behavior of insulated concrete sandwich wall panels subjected to wind pressure and suction10.3390/ma8031264 ↗
24. Committee A · 2014 · 520
25. Thermal performance of sandwich insulation system according to the type of form-tie10.4028/www.scientific.net/AMR.689.269 ↗
26. Thermal performance of sandwich insulation system for apartment buildings according to the shear connectors and insulation
27. Association KS · 2002
28. Ministry of Land IaT · 2011
29. AIK · 2009
30. ASCE · 2006
31. Frankl · 2008