Effects of environmental ageing on the static and cyclic bending properties of braided carbon fibre/PEEK bone plates
Source abstract
Abstract
Abstract The use of titanium and steel bone plates to fix fractured limbs can create problems due to stress shielding, bone resorption and subsequent refracture. Here, braided carbon fibre reinforced poly-ether-ether-ketone (CF/PEEK) was evaluated as a possible implant material that could reduce these problems. CF/PEEK bone plates were aged in a simulated body environment for up to 12 weeks and then mechanically tested in 3 and 4-point bending tests. Sample mass increased by around 0.3 wt.%, yet bending stiffness and strength remained unchanged. Scanning Electron Microscopy (SEM) showed no changes in failure modes with age. Braided CF/PEEK shows an excellent resistance to fatigue failure even after prolonged ageing, easily surpassing the fatigue life of commonly used stainless steel alloys such as 316L. In addition, CF/PEEK had half the stiffness of steel for the same static strength, which would reduce stress shielding. Together, the results suggest that CF/PEEK is a highly suitable material for bone plates and should be further investigated for this application.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Biomedical applications of polymer-composite materials: a review10.1016/S0266-3538(00)00241-4 ↗
2. A study of bone remodeling using metal-polymer laminates10.1002/jbm.820150610 ↗
3. Mechanical properties and micro-fracture behaviors of flat braided composites with a circular hole10.1016/S0263-8223(01)00024-1 ↗
4. Performance study of braided carbon/PEEK composite compression bone plates10.1016/S0142-9612(03)00065-6 ↗
5. Polyetheretherketone as a biomaterial for spinal applications10.1016/j.biomaterials.2005.07.011 ↗
6. The physical structure and mechanical properties of poly(ether ether ketone)
7. The short-term properties of carbon fibre PEEK composites
8. The influence of thermal history on the dynamic mechanical and dielectric studies of polyetheretherketone exposed to water and brine10.1016/S0032-3861(99)00259-1 ↗
9. PEEK biomaterials in trauma, orthopedic, and spinal implants10.1016/j.biomaterials.2007.07.013 ↗
10. Effect of hot water immersion on the performance of carbon reinforced unidirectional poly(ether ether ketone) (PEEK) composites: stress rupture under end-loaded bending10.1016/j.compositesa.2006.03.004 ↗
11. The long-term mechanical integrity of non-reinforced PEEK–OPTIMA polymer for demanding spinal applications: experimental and finite-element analysis10.1007/s00586-005-0915-5 ↗
12. Long-term compressive property durability of carbon fibre-reinforced polyetheretherketone composite in physiological saline10.1016/0142-9612(96)81415-3 ↗
13. Influence of micro-structures on bending properties of braided laminated composites10.1016/j.compscitech.2005.08.003 ↗
14. Biological response to chopped-carbon-fiber-reinforced PEEK10.1002/jbm.820260202 ↗
15. In vitro biocompatibility of polyetheretherketone and polysulfone composites10.1002/jbm.820240207 ↗
16. Fatigue fracture of bone plates10.1016/S0020-1383(80)80044-1 ↗
17. Fatigue characteristics of metallic biomaterials10.1016/j.ijfatigue.2006.09.021 ↗
18. Fatigue of biomaterials: a review10.1016/S0142-1123(00)00052-9 ↗
19. ASTM. D790-07: Standard test methods for flexural properties of unreinforced and reinforced plastics and electrical insulating materials. Philadelphia: American Society for Testing and Materials; 2007.
20. ISO. 9585:1990(E): Implants for surgery – determination of bending strength and stiffness of bone plates. Geneva: International Organization for Standardization; 1998.
21. ASTM. F382-95: Standard test method for static bending properties of metallic bone plates. Philadelphia: American Society for Testing and Materials; 1995.
22. Engineering considerations in the internal fixation of fractures of the tibial shaft10.1302/0301-620X.51B4.754 ↗
23. In vitro corrosion fatigue of 316L cold worked stainless steel10.1002/jbm.820260903 ↗
24. The environmental fatigue behaviour of carbon fibre reinforced polyether ether ketone10.1007/BF00555899 ↗
25. Thermoplastic resins
26. Processing of thermoplastic-based advanced composites
27. Effect of water absorption in polymers at low and high temperatures10.1016/S0032-3861(98)00560-6 ↗
28. Fatigue damage mechanisms in unidirectional carbon-fibre-reinforced plastics10.1023/A:1004684228765 ↗
29. In-body corrosion fatigue failure of a stainless steel orthopaedic implant with a rare collection of different damage mechanisms10.1016/j.engfailanal.2006.11.037 ↗
30. Premature fracture of a stainless steel 316L orthopaedic plate implant by alternative episodes of fatigue and cleavage decoherence10.1016/j.engfailanal.2006.11.010 ↗
31. Fatigue behavior of type 316 stainless steel under simulated body conditions10.1002/jbm.820050313 ↗
32. Development of fatigue lifetime predictive test methods for hip implants: Part I. Test methodology10.1016/S0142-9612(98)00031-3 ↗
33. Fibrous composite materials in dentistry and orthopaedics: review and applications10.1016/j.compscitech.2003.09.012 ↗