Effect of FRP wrapping in seismic performance of RC buildings with and without special detailing – A case study
Source abstract
Abstract
The results of a numerical investigation into the efficiency of glass fibre reinforced polymers (GFRPs) in improving the seismic performance of an 8-storey moment resisting reinforced concrete building are presented. In order to assess the effect of the transverse reinforcement, the building is detailed with different levels of transverse reinforcement representing well-confined and poorly-confined conditions. Although GFRP wrapping of columns at critical regions is the main retrofitting technique considered in this study, the effect of increasing the beam ductility on the seismic performance of a structure is also evaluated for the code-compliant building. The retrofitting strategy aims to provide both columns and beams with more ductility and energy dissipation instead of increasing the lateral strength. The load–displacement curves obtained from pushover analysis of the frames are then used in the seismic assessment using a capacity spectrum approach (the N2 method). The results confirm that GFRP wraps is capable of improving the seismic performance and ductility of the poorly-confined structure substantially, compared to the original structure. However, it was found that using FRP composites in order to increase the ductility of code-compliant building only, was not that effective.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Seismic Performance and Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (57)
Show source-provided references
1. Extending service life of concrete and masonry structures with fibre composites10.1016/S0950-0618(97)00054-8 ↗
2. Reinforced concrete rectangular beams strengthened with CFRP laminates10.1016/1359-8368(95)00044-5 ↗
3. Experiments and analytical comparison of RC beams strengthened with CFRP composites10.1016/S1359-8368(03)00090-8 ↗
4. Repair of earthquake-damaged RC columns with FRP wraps
5. Performance of fibre-reinforced polymer-wrapped reinforced concrete column under combined axial–flexural loading
6. Effect of confinement using fibre-reinforced polymer or fibre-reinforced concrete on seismic performance of gravity load-designed columns
7. Behaviour of large-scale rectangular columns confined with FRP composites10.1061/(ASCE)CC.1943-5614.0000051 ↗
8. Structural evaluation of full-scale FRP-confined reinforced concrete columns10.1061/(ASCE)CC.1943-5614.0000152 ↗
9. Finite element modeling of RC connections strengthened with FRP laminates
10. An experimental study on Kevlar strengthening of beam–column connections10.1016/S0263-8223(00)00187-2 ↗
11. Efficiency of beam–column joint strengthened by FRP laminates10.1163/092430409X12605406698192 ↗
12. Web-bonded FRPs for relocation of plastic hinges away from the column face in exterior RC joints10.1016/j.compstruct.2011.04.002 ↗
13. FRPC reinforced concrete beam–column joints under cyclic excitation10.1016/j.compstruct.2004.08.022 ↗
14. Analysis of FRP-strengthened RC beam–column joints10.1061/(ASCE)1090-0268(2002)6:1(41) ↗
15. Shear enhancement of reinforced concrete beams strengthened with FRP composite laminates10.1016/j.compositesb.2006.10.002 ↗
16. A numerical evaluation of the interlaminar stress state in externally FRP plated RC beams10.1016/S1359-8368(03)00018-0 ↗
17. Flexural behaviour of concrete beams reinforced with GFRP bars10.1111/j.1475-1305.2009.00662.x ↗
18. Seismic behaviour of a full-scale RC frame repaired using CFRP laminates10.1016/j.engstruct.2005.01.002 ↗
19. Seismic strengthening of an under-designed RC structure with FRP10.1002/eqe.749 ↗
20. Seismic behaviour of deficient RC frames strengthened with CFRP composites10.1016/j.engstruct.2010.05.026 ↗
21. Seismic performance of ordinary RC frames retrofitted at joints by FRP sheets10.1016/j.engstruct.2010.04.008 ↗
22. Computers and Structures Inc. Static and dynamic finite element analysis of structures. SAP 2000. 14.1.0 ed. Berkeley, CA; 2009.
23. A nonlinear analysis method for performance-based seismic design10.1193/1.1586128 ↗
24. Permanent committee for revising the Iranian code for seismic resistant design of buildings. Iranian code of practice for seismic resistant design of buildings (Standard No. 2800–05). 3rd ed. Tehran (Iran): Building and Housing Research Center (BHRC); 2005.
25. American Society of Civil Engineering (ASCE). Prestandard and commentary for the seismic rehabilitation of buildings (FEMA-356). Washington (DC): Federal Emergency Management Agency; 2000.
26. ACI Committee 318. Building code requirements for structural concrete (ACI 318–02) and commentary (ACI 318R-02). Farmington Hills, MI: American Concrete Institute; 2002.
27. Pros and cons of a pushover analysis of seismic performance evaluation10.1016/S0141-0296(97)00092-8 ↗
28. Seismic performance of reinforced concrete moment resisting frames10.1016/j.engstruct.2006.11.029 ↗
29. Static pushover versus dynamic collapse analysis of RC buildings10.1016/S0141-0296(00)00068-7 ↗
30. Effects of plastic hinge properties in nonlinear analysis of reinforced concrete buildings10.1016/j.engstruct.2006.01.017 ↗
31. Analytical assessment of an irregular RC frame for full-scale 3D pseudo-dynamic testing Part I: Analytical model verification10.1080/13632460509350535 ↗
32. Park · 1975
33. Imbseon and Associates Inc. Cross section analysis program for structural engineers. XTRACT. 3.0.8 ed. California; 2011.
34. Theoretical stress–strain model for confined concrete10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗
35. ASTM A615M. Standard specification for deformed and plain carbon-steel bars for concrete reinforcement. Philadelphia (PA): American Society for Testing and Materials; 2009.
36. Stress–strain behaviour of concrete confined by overlapping hoops at low and high strain rates
37. Paulay · 1992
38. ATC. Seismic evaluation and retrofit of concrete buildings (ATC-40). California: Applied Technology Council; 1996.
39. Seismic performance of ductile and nominally ductile reinforced concrete moment resisting frames. II. Analytical study10.1139/l97-096 ↗
40. Seismic performance of ductile and nominally ductile reinforced concrete moment resisting frames. I. Experimental study10.1139/l97-097 ↗
41. Carr AJ. RUAUMOKO the Maori god of volcano and earthquake. Computer Program Library. 27 January 1996 ed. Christchurch (New Zealand): Department of Civil Engineering, University of Canterbury; 1996.
42. NBCC. National building code of Canada. Ottawa (Ont): Associate Committee on the National Building Code, National Research Council of Canada; 1995.
43. CSA. Design of concrete structures for building. Standard CAN-A-233-94. Rexdale (Ont).: Canadian Standards Association; 1994.
44. Optimal performance-based design of FRP jackets for seismic retrofit of reinforced concrete frames10.1016/j.compositesb.2006.07.016 ↗
45. Design-oriented stress–strain model for FRP-confined concrete10.1016/S0950-0618(03)00045-X ↗
46. Design-oriented stress–strain model for FRP-confined concrete in rectangular columns10.1177/0731684403035429 ↗
47. Interaction diagram methodology for design of FRP-confined reinforced concrete columns10.1016/j.conbuildmat.2008.06.010 ↗
48. ACI Committee 440.2. Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures (ACI 440.2R-08). Farmington Hills (MI): American Concrete Institute; 2008.
49. Concrete society. Design guidance for strengthening concrete structures with fibre composite materials. Technical Rep. No. 55, 2nd Ed., Crowthorne, Berkshire, UK; 2004.
50. Talaeitaba SB. Ductility enhancement of RC joints with FRP laminates. Isafahn (Iran): Isfahan University of Technology (IUT); 2003 [n Farsi].
51. International conference of building officials. Whittier (CA): Uniform Building Code (UBC); 1997.
52. IBC. International building code falls church. Virginia: International Code Council; 2006.
53. ATC. Seismic evaluation and retrofit of concrete buildings (ATC-40). California: Applied Technology Council; 1996.
54. ACI. Guide for the design and construction of structural concrete reinforced with FRP bars (ACI 440.1R-06). Farmington Hills (MI): American Concrete Institute; 2006.10.1061/40753(171)158 ↗
55. CSA. Specification for fibre reinforced polymers (CSA-S807-10). Toronto (Canada): Canadian Standards Association (CSA) International; 2010.
56. Fib bulletin no. 40. FRP reinforcement in RC structures. 2007 160pp.
57. JSCE. Recommendation for upgrading of concrete structures with use of continuous fiber sheets. Concrete Engineering Series 41. Tokyo (Japan): Japan Society of Civil Engineers; 2001.