journal article·2015-01

Composite and non-composite behaviors of foam-insulated concrete sandwich panels

Junsuk Kang

Publisher page

Abstract

Abstract The structural behaviors of foam-insulated concrete sandwich panels subjected to uniform pressure have been evaluated. This study showed that the interface conditions such as composite and non-composite had a significant effect on the response of foam-insulated concrete sandwich panels, indicating that the simulated shear tie resistance should indeed be incorporated in numerical analyses. Finite element models were developed to simulate the detailed shear resistance of connectors and the nonlinear behaviors of concrete, foam and rebar components. The models were then validated using data from static tests performed at the University of Missouri. The modeling approach used here was compatible with the American Concrete Institute (ACI) Code and existing design practices. The results of this study will therefore provide improved methodology for the analysis and design of foam-insulated sandwich panels under both static and blast loadings.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Masonry and Concrete Structural Analysis · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (15)

Show source-provided references
1. Size effect on strength of laminate-foam sandwich plates: finite element analysis with interface fracture10.1016/j.compositesb.2009.03.005 ↗
2. An experimental investigation of static and fatique behavior of sandwich composite panels joined by fasteners10.1016/S1359-8368(01)00007-5 ↗
3. Advanced composite sandwich structure design for energy absorption applications: Blast protection and crashworthiness10.1016/j.compositesb.2012.02.025 ↗
4. Non-linear finite element analysis of inserts in composite sandwich structures10.1016/j.compositesb.2008.05.004 ↗
5. A new structurally and thermally efficient precast sandwich panel system10.15554/pcij.07011994.90.101 ↗
6. Precast/Prestressed Concrete Institute (PCI) Committee Report. State-of-the-art of precast/prestressed sandwich wall panels. PCI J, vol. 56(2), 2011. p. 131–76.10.15554/pcij56.2-06 ↗
7. Full scale testing of precast concrete sandwich panels
8. Structural performance of hybrid GFRP/steel concrete sandwich panels
9. Naito CJ, Dinan RJ, Fisher JW, Hoemann JM. Precast/prestressed concrete experiments – series 1 (volume 1). Interim Report. AFRL-RX-TY-TR-2008-4616. Air Force Research Laboratory, 2008.10.21236/ADA501975 ↗
10. Naito CJ. Analytical assessment of the blast resistance of precast, prestressed concrete components. Interim report. AFRL-ML-TY-TP-2007-4529. Air Force Research Laboratory, 2007.
11. Newberry CM, Davidson JS, Hoemann JM, Bewick BT. Simulation of Prestressed Concrete Sandwich Panels Subjected to Blast Loads. Air Force Research Laboratory, AFRL-RX-TY-TP-2010-0014, Preprint, Feb. 2010.10.1061/41130(369)163 ↗
12. SIMULIA. ABAQUS Analysis User’s Manual Version 6.7. 2007.
13. Naito CJ, Hoemann JM, Bewick BT, Hammons MI. Evaluation of shear tie connectors for use in insulated concrete sandwich panels. Interim report. AFRL-Rx-TY-TR-2009-4600. Air Force Research Laboratory, 2009.
14. American Concrete Institute (ACI). Building code requirements for structural concrete and commentary. ACI 318, Farmington Hills, Mich, 2008.
15. Nilson · 2004