Buckling, collapse and failure analysis of FRP sandwich panels
Source abstract
Abstract
Abstract Rectangular orthotropic fiber-reinforced plastic (FRP) sandwich panels were tested for buckling in uni-axial compression. The panels, with 0.32 cm (0.125 in.) face sheets and a 1.27 cm (0.5 in.) core of either balsa or linear poly(vinyl chloride) (PVC) foam, were tested in two sizes: 154×77 cm2 (72×36 in.2) and 102×77 cm2 (48×36 in.2). The sandwich panels were fabricated using the vacuum-assisted resin transfer molding process. The two short edges of the sandwich panels were clamped, while the two long edges were simply supported for testing. The clamped panel ends were potted into a steel frame. The experimental elastic buckling loads were then measured using strain gauges fixed to both sides of the panels. A total of 12 panels were tested under uni-axial compression. Bifurcation in the load versus engineering strain curve was noted in all cases. For all six sandwich panels tested using balsa core, the type of failure was easily identified as face sheet delamination followed by core shear failure. For all six PVC foam core sandwich panels tested, the type of failure consisted of core shear failure with little or no face sheet delamination. In the failed balsa core panels there was little or no evidence of balsa remaining on the FRP face sheet, however, in the PVC foam core panels there were ample amounts of foam left on the FRP face sheet. It was concluded that although the buckling loads for the foam core panels were not as high as those for the balsa core panels, PVC foam core bonding to the FRP face sheets was superior to balsa core bonding.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete · Composite Structure Analysis and Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. Sorathia U, et al. Fire safety of marine composites. 45th SAMPE ISSE; May 2000. p. 1744.
2. Sorathia U, Beck C. Fire protection of glass/vinyl ester composites for structural applications. 41st SAMPE ISSE; March 1996. p. 687.
3. Veinot D, et al. Inorganic intumescent coating for improved fire protection of GRP. 44th SAMPE ISSE; May 1999. p. 1385.
4. Low-cost design fabrication of composite ship structures10.1016/0951-8339(94)90036-1 ↗
5. Silvergleit M, Deppa RW, Edelstein HP. Potential application of advanced composites for high perfromance craft. Proceeding of the Fifth SAMPE National Technical Conference, Kamesha Lake, NY, vol. 5; October 9–14, 1973. p. 195–206.
6. A review of the design and materials evaluation programme for the GRP/foam sandwich composite hull of the RAN minehunter10.1016/0010-4361(84)90707-9 ↗
7. Zvanik M. Using GRP sandwich construction in the marine environment: past and the future. Applying Composites in the Marine Environment, Savannah, Georgia; November 8–10, 1993. F21-1F21.
8. Analytic and finite element solutions for bending and buckling of orthotropic rectangular plates10.1016/S0020-7683(96)00114-X ↗
9. Experimental numerical and analytical results for bending and buckling of rectangular plates10.1016/S0263-8223(98)00112-3 ↗
10. Experimental results for the bending and buckling of rectangular orthotropic fiber-reinforced (FRP) plate structures
11. Plantema · 1966
12. Buckling and failure of sandwich plates with graphite-epoxy faces and various cores10.2514/3.45573 ↗
13. Local failure of plastic-foam core sandwich panels10.1061/JSDEAG.0002239 ↗
14. Experimental buckling loads of sandwich panels with carbon fibre faceplates10.1017/S0001925900006703 ↗