Abstract
A polymeric hybrid composite system made of high-performance concrete (HPC) and an innovative carbon/epoxy reinforced polymer (CFRP) unidirectional laminates was proposed as a retrofit system to enhance flexural strength and ductility of reinforced concrete (RC) slabs. The effectiveness of the proposed system was confirmed through experimental evaluation of three full-scale one-way slabs having two continuous spans. In this study, the results of the loading tests for the hybrid high-performance retrofit system are presented and discussed. Design limits to derive a flexural failure of a continuous RC slab strengthened with the hybrid retrofit system are extracted. Using the proposed design limits, the procedure of a flexural failure design for a continuous RC slab strengthened with the hybrid retrofit system is demonstrated with numerical examples for two types of the retrofit systems with respect to overlay strength. The flexural failure design limits can be extended for flexural and shear strengthening design with externally bonded FRP to ensure flexure failure for a continuous flexural members.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (12)
Show source-provided references
1. Nonlinear transient analysis of reinforced concrete slab subjected to blast loading and retrofitted with CFRP composites10.1016/S1359-8368(01)00044-0 ↗
2. Strengthening of two-way concrete slabs with FRP composite laminates10.1016/S0950-0618(02)00092-2 ↗
3. Numerical evaluation of the retrofit effectiveness for GFRP retrofitted concrete slab subjected to blast pressure10.1016/j.compstruct.2009.10.031 ↗
4. Fleming CJ, King GEM. The development of structural adhesives for three original uses in South Africa. In: RILEM international symposium, synthetic resins in building construction, Paris; 1967. p. 75–92.
5. Strengthening concrete structure, Part II
6. Design recommendations for the use of FRP for reinforcement and strengthening of concrete structures10.1002/pse.139 ↗
7. ACI Committee 440. Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures, ACI 440.2R-08, Farmington Hills, MI; 2008.
8. Strength and ductility of RC slabs strengthened with hybrid high-performance composite retrofit system10.1016/j.engstruct.2011.11.022 ↗
9. MacGregor · 2009
10. ACI Committee 318. Building code requirements for structural concrete (ACI 318-05) and commentary (318R-05), American Concrete Institute, Farmington Hills, MI; 2005.
11. Hognestad E. Study of combined bending and axial load in reinforced concrete members. University of Illinois, Bulletin Series, Bulletin 399; November 1951.
12. Reed CE, Peterman RJ, Rasheed HA. Evaluating FRP repair method for cracked prestressed concrete bridge members subjected to repeated loadings (phase 1), KTRAN report, No. K-TRAN: KSU-01-2; 2005.