Effects of steel fiber on the flexural behavior and ductility of concrete beams reinforced with BFRP rebars under repeated loading
Source abstract
Abstract
Abstract This study investigates the effects of concrete strength, steel fiber volume ratio, and steel fiber shapes on the flexural behavior and ductility of concrete beams reinforced with BFRP rebars under repeated loading with the aims of exploring the feasibility of using short discrete steel fiber to improve the ductility of beams, and proposing appropriate methods for evaluating their ductility. A four-point bending test was carried out on four steel fiber reinforced concrete (SFRC) beams with BFRP rebars and one beam reinforced with BFRP rebars only without steel fibers. Experimental results are reported in terms of the failure mode, flexural strength, load-deflection response, cracking behavior, and ductility, which reveals that the flexural strength of beams can be calculated using CSA S806-12 code method with an error of about 20%. Compared with ordinary concrete, the impact of steel fiber reinforcement on the service load of beams is more significant than that on their flexural strength; moreover, when steel fiber volume ratio increased from 0% to 1.0%, the deflection under service load decreased by 59.36%. In addition, the ductility of beam with 1.0% steel fiber volume ratio can be enhanced by 17% than that of concrete beam without steel fibers. Compared with energy ductility coefficient, displacement ductility coefficient, curvature ductility coefficient, the ductility coefficient of ACI 440.1R-15 prove to be more accurate in evaluating ductility of SFRC beams with BFRP rebars, and all the beams investigated in this study had a ductility factor greater than 4.0.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Flexural behavior of hybrid FRP/steel reinforced concrete beams10.1016/j.compstruct.2015.03.073 ↗
2. Long-term behavior of GFRP reinforcing bars10.1016/j.compstruct.2019.111283 ↗
3. Shear behaviour of inorganic polymer concrete beams reinforced with basalt FRP bars and stirrups10.1016/j.compstruct.2020.112901 ↗
4. Reliability-based design analysis of FRP shear strengthened reinforced concrete beams considering different FRP configurations10.1016/j.compstruct.2020.111957 ↗
5. Estimation of the crack width and deformation of FRP reinforced concrete flexural members with and without transverse shear reinforcement10.1016/j.engstruct.2013.11.005 ↗
6. Experimental study on flexural behavior of ECC-concrete composite beams reinforced with FRP bars10.1016/j.compstruct.2018.10.026 ↗
7. The effect of transverse and flexural reinforcement on deflection and cracking of GFRP bar reinforced concrete beams10.1016/j.compositesb.2018.12.127 ↗
8. Flexural behavior of ultra-high-performance fiber-reinforced concrete beams reinforced with GFRP and steel rerebars10.1016/j.engstruct.2015.12.003 ↗
9. Experimental study on flexural behavior of concrete beams reinforced with bundled hybrid steel/FRP rebars10.1016/j.engstruct.2019.109443 ↗
10. New ductile hybrid FRP reinforcing bar for concrete structures10.1061/(ASCE)1090-0268(1998)2:1(28) ↗
11. ACI Committee 440. Guide for the design and construction of concrete reinforced with FRP rebars. ACI 2015;440. 1R-15.
12. CAN/CSA S806-12, Canadian Standard Design and construction of building structures with fiber-reinforced polymers, Association; 2012.
13. GB50608-2010. Technical code for infrastructure application of FRP composites. China Metallurgical Construction Association, Beijing, China; 2010 (in Chinese).
14. Experimental study and prediction model for flexural behavior of reinforced SCC beams containing steel fibers10.1016/j.conbuildmat.2015.06.024 ↗
15. Behaviour of eccentric loading of FRP confined fibre steel reinforced concrete columns10.1016/j.conbuildmat.2008.05.024 ↗
16. The effect of steel fiber on the bond between concrete and deformed steel bar in SFRCs10.1016/j.conbuildmat.2012.09.098 ↗
17. Flexural cracks in steel fiber-reinforced lightweight aggregate concrete beams reinforced with FRP bars10.1016/j.compstruct.2020.112752 ↗
18. Effect of basalt fibers on the flexural behavior of concrete beams reinforced with BFRP rebars10.1016/j.compstruct.2019.02.050 ↗
19. Ductility characteristics of fiber-reinforced-concrete beams reinforced with FRP rerebars10.1016/j.conbuildmat.2010.11.040 ↗
20. Use of basalt fibers for concrete structures10.1016/j.conbuildmat.2015.07.138 ↗
21. Effect of steel and synthetic fibers on flexural behavior of high-strength concrete beams reinforced with FRP rebars10.1016/j.compositesb.2012.01.044 ↗
22. Flexural behavior of partially fiber-reinforced high-strength concrete beams reinforced with FRP rebars10.1016/j.conbuildmat.2017.12.003 ↗
23. Influence of fibers on flexural behavior and ductility of concrete beams reinforced with GFRP rebars10.1016/j.engstruct.2011.02.014 ↗
24. Aspects of behaviour of CFRP reinforced concrete beams in bending10.1016/j.conbuildmat.2006.08.014 ↗
25. Structural behaviour of RC beams externally strengthened with FRP sheets under fatigue and monotonic loading10.1016/j.engstruct.2012.03.024 ↗
26. Flexural fatigue analysis of a CFRP form reinforced concrete bridge deck10.1016/j.compstruct.2011.05.014 ↗
27. Prediction model for the flexural strength of steel fiber reinforced concrete beams with fiber-reinforced polymer bars under repeated loading10.1016/j.compstruct.2020.112609 ↗
28. Steel fiber reinforced concrete (JG/T 472-2015). China National Standard; 2015.
29. Multidirectional double punch test to assess the post-cracking behaviour and fibre orientation of FRC10.1016/j.conbuildmat.2014.02.023 ↗
30. Standard for test methods of concrete physical and mechanical properties (GB/T 50081-2019). China National Standard; 2019.
31. The method for basic mechanical properties of fiber reinforced polymer bar (GB/T 30022-2013). China National Standard; 2013.
32. A geometrically non-linear three-dimensional cohesive crack method for reinforced concrete structure10.1016/j.engfracmech.2008.06.019 ↗
33. A simple and robust three-dimensional cracking-particle method without enrichment10.1016/j.cma.2010.03.031 ↗
34. Naaman AE, Jeong SM. Structural ductility of concrete beams prestressed with FRP tendons. In: Taerwe L, editor. Proc of 2nd int RILEM symp (FRPRXS-2), non-metric (FRP) reinforcement for concrete structures, RILEM. London: E & FN Spon; 1995: 379–386.
35. Jaeger GL, Tadros G, Mufti AA. The concept of the overall performance factor in rectangular-section reinforced concrete beams. In: Proc of 3rd int symp on non-metallic (FRP) reinforcement for concrete structures, vol. 2, Sapporo, Japan; 1997: 551–58.
36. Canadian Standards Association (CSA). Canadian highway bridge design code. CSA S6-14, 2014, Mississauga, ON, Canada.