Compressive behavior of rectangular concrete-filled fiber-reinforced polymer and steel composite tube columns with stress-release grooves
Source abstract
Abstract
Abstract To investigate the behavior of rectangular concrete-filled fiber-reinforced polymer (FRP) and steel composite tube (CFCT) columns with stress-release grooves under axial compression, sixty specimens were fabricated and divided into five groups for axial compression testing. The main variables were the corner radius, the number of FRP layers, the steel tube thickness and the presence of stress-release grooves. The test results indicate that steel tubes and FRPs can complement each other and discontinuous steel tubes can provide an effective confinement force on in-filled concrete. The stress–strain responses of CFCT columns with stress-release grooves consist of a linear elastic stage, a nonlinear transition stage, a linear hardening stage and a residual stage. The ultimate strength of a CFCT column is in direct proportion to the number of FRP layers, the thickness of the steel tube and the value of the corner radius. Stress-release grooves only play a positive role in specimens with relatively large values of the corner radii (r ≥ 30 mm). A new model was suggested for calculating the ultimate stress of CFCT columns with stress-release grooves. The model is applicable for CFCT and concrete-filled steel tube (CFT) specimens with stress-release grooves; the predicted results agree well with the experimental statistics.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (45)
Show source-provided references
1. Performance of circular concrete-filled fiber-reinforced polymer-steel composite tube columns under axial compression10.1177/0731684414550836 ↗
2. Compressive behaviour of concrete-filled carbon fiber-reinforced polymer steel composite tube columns made of high performance concrete10.1016/j.compstruct.2019.111668 ↗
3. Experimental study on axially compressed circular CFST columns with improved confinement effect10.1016/j.jcsr.2017.10.025 ↗
4. Behaviour of CFRP-confined concrete-filled circular steel tube stub columns under axial loading10.1016/j.tws.2018.01.015 ↗
5. Cyclic lateral response of FRP-confined circular concrete-filled steel tubular columns10.1016/j.jcsr.2016.05.006 ↗
6. A novel seawater and sea sand concrete filled FRP-carbon steel composite tube column: Concept and behaviour10.1016/j.compstruct.2020.112421 ↗
7. Compressive behavior of FRP-confined reinforced concrete columns10.1016/j.engstruct.2016.11.052 ↗
8. Behaviour of FRP tube-concrete-encased steel composite columns10.1016/j.compstruct.2020.112139 ↗
9. Behavior of FRP-confined ultra-high performance concrete under eccentric compression10.1016/j.compstruct.2020.113040 ↗
10. Behavior of FRP confined UHPFRC-filled steel tube columns under axial compressive loading10.1016/j.jobe.2020.101511 ↗
11. FRP-confined recycled glass aggregate concrete: Concept and axial compressive behavior10.1016/j.jobe.2020.101288 ↗
12. Modeling for complete stress-strain curve of circular concrete columns confined with steel spiral and FRP10.1016/j.jobe.2021.103294 ↗
13. Compressive performance of high-strength seawater and sea sand concrete-filled circular FRP-steel composite tube columns10.1016/j.engstruct.2021.112357 ↗
14. Monotonic Axial Compressive Behaviour and Confinement Mechanism of Square CFRP-Steel Tube Confined Concrete10.1016/j.engstruct.2020.110802 ↗
15. Experimental investigation of FRP-confined concrete-filled stainless steel tube stub columns under axial compression10.1016/j.tws.2019.106483 ↗
16. Experimental investigation of rectangular concrete-filled fiber reinforced polymer (FRP)-steel composite tube columns for various corner radii10.1016/j.compstruct.2020.112311 ↗
17. Behavior of circular fiber-reinforced polymer–steel-confined concrete columns subjected to reversed cyclic loads: Experimental studies and finite-element analysis10.1061/(ASCE)ST.1943-541X.0002373 ↗
18. Evaluation of concrete filled steel tube column confined with FRP10.1520/JTE20180148 ↗
19. Slenderness effects on concrete-filled steel tube columns confined with CFRP10.1016/j.jcsr.2017.12.014 ↗
20. Compressive behavior of FRP-wrapped seawater sea-sand concrete with a square cross-section10.1016/j.conbuildmat.2020.120881 ↗
21. Effect of cross-sectional aspect ratio on rectangular FRP-Concrete-Steel double-skin tubular columns under axial compression
22. Evaluation of post-heating flexural behavior of steel fiber-reinforced high-strength concrete beams reinforced with FRP bars: Experimental and analytical results10.1016/j.engstruct.2020.111292 ↗
23. Experimental and analytical investigation on structural behavior of two-layer fiber-reinforced concrete beams reinforced with steel and GFRP rebars10.1016/j.conbuildmat.2020.121933 ↗
24. Prediction of shear behavior of steel fiber-reinforced rubberized concrete beams reinforced with glass fiber-reinforced polymer (GFRP) bars10.1016/j.compstruct.2020.113010 ↗
25. The effect of active and passive confining pressure on compressive behavior of STCC and CFST
26. Effect of axial loading conditions and confinement type on concrete-steel composite behavior
27. Tomii M, Sakino K, Xiao Y, Watanabe K. Earthquake resisting hysteretic behavior of reinforced concrete short columns confined by steel tube. Proceedings of the International Speciality Conference on Concrete Filled Steel Tubular Structures. 1985;Harbin Institute of Technology, Harbin, China.
28. Experimental behavior of circular concrete-filled steel tube stub columns10.1016/j.jcsr.2006.03.009 ↗
29. Study on the unbonded steel tube concrete structure
30. Behavior of square tubed steel reinforced-concrete (SRC) columns under eccentric compression10.1016/j.tws.2015.01.022 ↗
31. Compressive behaviors of rectangular concrete filled slotted steel tubular columns
32. Compressive behavior of CFRP-steel composite tubed steel-reinforced columns with high-strength concrete10.1016/j.jcsr.2018.08.028 ↗
33. Axial behaviour of circular steel tubed concrete stub columns confined by CFRP materials10.1016/j.conbuildmat.2018.02.131 ↗
34. Metallic materials tensile testing at ambient temperature. Beijing: Standard Press of China; 2010.
35. Test method for tensile properties of orientation fiber reinforced polymer matrix composite materials Beijing: Standard Press of China; 2014.
36. Behaviour of concrete-encased concrete-filled FRP tube (CCFT) columns under axial compression10.1016/j.engstruct.2017.05.061 ↗
37. Compressive behavior of FRP-confined concrete-filled PVC tubular columns10.1016/j.compstruct.2016.01.004 ↗
38. Eccentric compressive behavior of steel fiber-reinforced RC columns strengthened with CFRP wraps: Experimental investigation and analytical modeling
39. Strengthening of heat-damaged steel fiber-reinforced concrete using CFRP composites: Experimental study and analytical modeling10.1016/j.istruc.2021.03.084 ↗
40. Effect of continuous spirals on uni-axial strength and ductility of CFST columns10.1016/j.jcsr.2014.10.007 ↗
41. Confinement effect of ring-confined concrete-filled-steel-tube columns under uni-axial load10.1016/j.engstruct.2014.02.013 ↗
42. FRP retrofit of low and medium strength circular and rectangular reinforced concrete columns10.1061/(ASCE)0899-1561(2008)20:2(169) ↗
43. Design model for square RC columns under compression confined with CFRP10.1016/j.compositesb.2013.09.052 ↗
44. Theoretical stress-strain model for confined concrete10.1061/(ASCE)0733-9445(1988)114:8(1804) ↗
45. Confinement effectiveness of circular concrete-filled steel tubular columns under axial compression10.1016/j.jcsr.2019.03.012 ↗