journal article·2018-03

A numerical approach for modeling response of fiber reinforced polymer strengthened concrete slabs exposed to fire

V.K.R. Kodur, P.P. Bhatt

Publisher page

Abstract

Abstract A numerical model for evaluating the performance of fiber-reinforced polymer (FRP) strengthened reinforced concrete (RC) slabs under fire conditions is presented. The numerical model utilizes a macroscopic finite element based approach to trace thermo-mechanical response of FRP-strengthened RC slabs from linear elastic stage to collapse under fire conditions. The model accounts for temperature dependent properties of concrete, steel, FRP, and fire insulation as well as for temperature induced degradation of bond between concrete and FRP. The model is validated by comparing predicted response of FRP strengthened RC slabs with measured temperatures and deflections in fire tests. A case study is also presented to compare fire performance of RC slabs with and without FRP strengthening, as well as with different insulation and bond configurations. Results from the analysis indicate that a FRP strengthened RC slab, without any fire insulation, yields lower fire resistance as compared to conventional RC slab. Also, temperature induced bond degradation significantly influences fire performance of an FRP strengthened RC slab and neglecting bond degradation may lead to un-conservative estimation of fire resistance.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Fire effects on concrete materials · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. ACI 216.1-14. Code requirements for determining fire resistance of concrete and masonry construction assemblies. Farmington Hills, MI, USA: American Concrete Institute (ACI); 2014.
2. ACI 440.2R-17. Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures. Farmington Hills, MI, USA: American Concrete Institute (ACI); 2017.
3. Behavior of fiber reinforced polymer-strengthened T-beams and slabs in fire10.1680/stbu.11.00014 ↗
4. The experimental behavior of FRP-strengthened RC beams subjected to design fire exposure10.1016/j.engstruct.2011.03.010 ↗
5. Effect of bond degradation on fire resistance of FRP-strengthened reinforced concrete beams10.1016/j.compositesb.2010.11.004 ↗
6. Anderberg · 1976
7. ANSYS · 2017 · vol. 8
8. Performance of one-way reinforced concrete slabs with externally bonded fiber-reinforced polymer strengthening
9. ASCE 7-16. Minimum design loads and associated criteria for buildings and other structures. Reston, VA, USA: American Society of Civil Engineers; 2016.
10. ASTM E119. Standard test methods for fire tests of building construction and materials. West Conshohocken, PA, USA: American Society for Testing and Materials; 2016.
11. Fiber-reinforced polymer composites for construction—state-of-the-art review10.1061/(ASCE)1090-0268(2002)6:2(73) ↗
12. Bénichou N, Sultan MA, MacCallum C, Hum JK. Thermal properties of wood, gypsum and insulation at elevated temperatures. Internal Report IRC IR-710, Institute for Research in Construction, National Research Council of Canada, Ottawa, Canada; 2001.
13. Response to fire of concrete structures that incorporate FRP10.1002/pse.198 ↗
14. Blontrock H, Taerwe L, Vandevelde P. Fire tests on concrete beams strengthened with fiber composite laminates. In: Proceedings of the international PhD symposium in civil engineering, Vienna (Austria), October 5th–7th, ed. Konrad Bergmeister 2; 2000, p. 151–61.
15. Fire testing of concrete slabs strengthened with fiber composite laminates
16. Deformation controlled nonlinear analysis of prestressed concrete continuous beams10.15554/pcij.09011990.42.55 ↗
17. Canadian Standards Association (CSA) S806–02. Design and construction of building components with fiber-reinforced polymers. CAN/CSA S806–02, Rexdale, Canada; 2002.
18. Evaluation and prediction of temperature-dependent tensile strength of unidirectional carbon fiber-reinforced polymer composites10.1177/0731684411411002 ↗
19. Cook · 2007
20. Bond-slip model for frp laminates externally bonded to concrete at elevated temperature10.1061/(ASCE)CC.1943-5614.0000337 ↗
21. Finite element modeling of insulated frp-strengthened RC beams exposed to fire
22. Eurocode 1. Actions on Structures. Part 1–2: General actions-actions on structures exposed to fire. European Committee for Standardization, Brussels, Belgium; 2002.
23. Eurocode 2. EN 1992-1-2 design of concrete structures, Part 1-2: general rules-structural fire design. European Committee for Standardization, Brussels, Belgium; 2004.
24. Fédération Internationale du Béton (FIB). Design and use of externally bonded FRP reinforcement for RC structures. Bulletin 14, Lausanne, Switzerland; 2001.
25. Fire behavior of FRP-strengthened reinforced concrete structural elements: a state-of-the-art review10.1016/j.compositesb.2015.05.045 ↗
26. Thermal response of graphite epoxy composite subjected to rapid heating10.1177/002199838101500503 ↗
27. A comprehensive creep model10.1115/1.3609648 ↗
28. Harmathy · 1993
29. Modeling of insulated CFRP strengthened reinforcement exposed to fire10.1016/j.engstruct.2009.08.008 ↗
30. http://www.sp-reinforcement.ch.
31. IBC · 2015
32. ISO 834 ISO standard 834: fire resistance tests-elements of building construction. International Organization for Standardization, Geneva, Switzerland; 2002.
33. Numerical model for tracing the response of FRP-strengthened RC beams exposed to fire10.1061/(ASCE)CC.1943-5614.0000129 ↗
34. Effect of temperature on thermal properties of spray applied fire resistive materials10.1016/j.firesaf.2013.09.011 ↗
35. Lie T.T. Structural fire protection. ASCE manuals and reports of engineering practice 78, New York, NY, USA: ASCE; 1992.
36. Failure modes of reinforced concrete beams strengthened with carbon fiber sheet in fire10.1016/j.firesaf.2009.05.006 ↗
37. Fire protection systems for reinforced concrete slabs strengthened with CFRP laminates10.1016/j.conbuildmat.2013.05.019 ↗
38. Bond-slip models for FRP sheets/plates bonded to concrete10.1016/j.engstruct.2005.01.014 ↗
39. Mallick · 1993
40. Mouritz · 2006
41. Fire resistance of carbon FRP reinforced concrete beams10.1680/macr.2007.59.4.245 ↗
42. Evaluation of FRP as reinforcement for concrete bridges
43. Bonded fiber reinforced polymer strengthening in a real fire10.1260/136943309790327743 ↗
44. William · 1990
45. Fire insulation schemes for FRP-strengthened concrete slabs10.1016/j.compositesa.2005.05.028 ↗
46. Fire endurance of fiber-reinforced polymer strengthened concrete T-beams
47. Effect of temperature on strength and stiffness properties of near-surface mounted FRP reinforcement10.1016/j.compositesb.2013.10.055 ↗
48. Heat Transfer Principles in Thermal Calculation of Structures in Fire10.1016/j.firesaf.2015.08.006 ↗