journal article·2022-01Open access

New type of CFRP reinforcement and technique for the flexural strengthening of RC balconies

Joaquim A.O. Barros, Fábio P. Figueiredo, Inês G. Costa, Filipe N.F.M. Dourado

Abstract

Abstract The present work assesses the potentialities of a new carbon fibre reinforced polymer (CFRP) bar, applied according to a hybrid technique for the flexural strengthening of cantilever type reinforced concrete (RC) structures, such as the case of RC balconies. The CFRP bar is formed by an inclined extremity that is inserted into a hole according to the embedded through section (ETS) technique, a part that is applied according to the near-surface mounted (NSM) technique, and a transition zone between these two parts. The anchorage conditions of the ETS part of the CFRP bar allow limiting the strengthening intervention to the cantilever zone of the balcony, with an almost null intrusion to the interior of the building. The effectiveness of this CFRP reinforcement and technique was assessed by testing 9 double-sided RC balcony prototypes, in a total of 18 tests. The inclination of the ETS part of the CFRP bar (15° and 30°), the concrete strength class (C25 and C35) and the ratio of existing flexural tensile reinforcement ( ρ ls =0.28% and 0.44%) were the variables investigated in terms of flexural strengthening performance. The results showed that the strengthening effectiveness has increased with the decrease of the inclination of the ETS part of the CFRP bar. A reinforcement ratio of 0.17% of CFRP bars with an extremity at 15° inclination, has doubled the load-carrying capacity of the corresponding reference prototypes. The applicability of the most recent formulation of the fib bulletin 90 for the flexural strengthening of RC elements with NSM CFRP reinforcements was assessed for this type of application. The ratio between maximum load registered experimentally and predicted with fib formulation was 0.95 with a standard deviation of 0.08. However, this high level of predictive performance requires the effective tensile strength of the transition zone of the CFRP bar to be known, which is still a critical aspect of the current generation of CFRP bars. A numerical approach was developed, capable of estimating the force–deflection, the strains and stresses in the constituent materials and evolution of stiffness degradation of the strengthened structures during the loading process, and its high predictive performance was also demonstrated by simulating the experimental tests carried out.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. De Lorenzis · 2002
2. Teng JG, De Lorenzis L, Wang B, Li R, Wong TN, Lam L. Debonding failures of RC beams strengthened with near surface mounted CFRP strips. ASCE J Compos Constr, 10(2), 92-105.10.1061/(ASCE)1090-0268(2006)10:2(92) ↗
3. Barros JAO, Fortes AS. Flexural strengthening of concrete beams with CFRP laminates bonded into slits. J Cem Concr Compos, 27(4), 471-480.10.1016/j.cemconcomp.2004.07.004 ↗
4. Flexural and shear strengthening with composite materials – the influence of cutting steel stirrups to install CFRP strips10.1016/j.cemconcomp.2010.03.003 ↗
5. Flexural and shear strengthening of reinforced concrete beams with a hybrid CFRP solution10.1016/j.compstruct.2020.113004 ↗
6. Flexural behavior of RC T- section beams strengthened with different configurations of CFRP laminates
7. Grid U-wrap anchorage for reinforced concrete beams strengthened with carbon fiber-reinforced polymer sheets10.14359/51716772 ↗
8. Bisby · 2005
9. Fire behaviour of FRP-strengthened reinforced concrete structural elements: A state-of-the-art review10.1016/j.compositesb.2015.05.045 ↗
10. Simultaneous flexural and punching strengthening of RC slabs according to a new hybrid technique using U-shape CFRP laminates10.1016/j.compstruct.2016.10.009 ↗
11. Strength degradation in curved fiber-reinforced polymer (FRP) bars used as concrete reinforcement10.3390/polym12081653 ↗
12. Firmo JP, Correia JR. Fire behaviour of thermally insulated RC beams strengthened with NSM-CFRP strips: Experimental study. Compos Part B: Eng, Volume 76, 2015, Pages 112-121, ISSN 1359-8368, https://doi.org/10.1016/j.compositesb.2015.02.018.10.1016/j.compositesb.2015.02.018 ↗
13. Barros JAO, Rezazadeh M, Costa IG, Baghi H, Hosseini MRM, Mastali M, Laranjeira J. Flexural and shear/punching strengthening of RC beams/slabs using hybrid NSM-ETS technique with innovative CFRP laminates. Insights and Innovations in Structural Engineering, Mechanics and Computation, Alphose Zingoni (Eds), 5-7 September 2016, Cape Town, South Africa.10.1201/9781315641645-246 ↗
14. Investigation of a New Strengthening Technique for RC beams Using Carbon FRP Ropes as Transverse Reinforcements10.3390/fib6030052 ↗
15. Flexural retrofit of support regions of reinforced concrete beams with anchored FRP ropes using NSM and ETS methods under reversed cyclic loading
16. Silva CAN, Ciambella J, Barros JAO, Costa IG. Modelling of CFRP laminates applied according to the ETS/NSM technique. 9th International Conference on Fibre-Reinforced Polymer (FRP) Composites in Civil Engineering (CICE 2018), Paris 17-19 July 2018.
17. Matthys S, Triantafillou T, Balázs G, Barros JAO, Bilotta, A, Bournas D, et al. Externally applied FRP reinforcement for concrete structures. fib 90 Bulletin, Technical Report, Task Group 5.1, ISBN 978-2-88394-131-1, May 2019.10.35789/fib.BULL.0090.Ch01 ↗
18. Model Code 2010. fib Model Code for Concrete Structures 2010. International Federation for Structural Concrete (fib). Ernst & Sohn, Berlin, Germany; 2013.
19. Analytical bond model for general type of reinforcements of finite embedment length in cracked cement based materials10.1016/j.ijsolstr.2019.02.018 ↗
20. EN 206-1. Concrete - Part 1: Specification, performance, production and conformity. European standard, CEN, 69 pp. (2000).
21. 10002–1, “Metallic materials - Tensile testing. Part 1: Method of test (at ambient temperature)”
22. 527–5, “Plastics - Determination of tensile properties - Part 5: Test conditions for unidirectional fibre-reinforced plastic composites”
23. Tensile creep of a structural epoxy adhesive: experimental and analytical characterization10.1016/j.ijadhadh.2015.02.006 ↗
24. ISO · 1993
25. Bond of NSM FRP strengthening concrete: round robin test initiative10.1061/(ASCE)CC.1943-5614.0000579 ↗
26. Varma · 2013