journal article·1990-01-01

Correlation between scanning tunneling microscopy/spectroscopy images and apex profiles of scanning tips

Osamu Nishikawa, Masahiko Tomitori, Fumikazu Iwawaki, Nobuo Hirano

Publisher page

Abstract

Variations of topographic and current images with bias voltages were examined utilizing the current imaging tunneling spectroscopy (CITS) and dual-polarity tunneling imaging (DPTI) techniques. While the CITS and DPTI images of the Si(111)-(7×7) reconstructed structure at the specimen voltage of +2 V and the DPTI image at −2 V are reliably reproducible exhibiting bright Si adatoms and dark corner holes, the CITS current image at −2 V often showed reversed contrast grey-scale images with bright corner holes. The observed reversed image is explained as the result of the difference in the effective tunneling barrier and the surface state density of the tip apex and specimen, and also as the effect of the atomic arrangement and composition and profile of the tip apex.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Surface and Thin Film Phenomena · Force Microscopy Techniques and Applications · Advanced Materials Characterization Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Materials Science and Engineering, The Graduate School at Nagatsuta, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama 227 Japan

References

Reference metadata was not supplied for this record.