journal article·1983-04-01Open access

Theoretical determination of ionization efficiency for an orbitron device and variation with the main working parameters

B. Petit, M. L. Feidt

Abstract

A knowledge of the distribution function for electrons describing stable and unstable trajectories, respectively, and the evaluation of the stable electrons’ mean lifetime deduced from the properties of the ‘‘electrostatic mirror’’ corresponding to the endplates, allow us to perform a theoretical calculation of ionization efficiency for an orbitron device. The ionization efficiency of the device is calculated for various geometrical and electrical parameters using the preceding theoretical considerations. Comparison between experiments and calculations allow us to validate the theoretical model.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · Nuclear Physics and Applications · Plasma Diagnostics and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institut National Polytechnique de Lorraine, Laboratoire E.R.M.E.S. (E.R.A. 892), 2, rue de la Citadelle-8.P. 850, 54011 Nancy Cedex-France