Thirty‐year durability of a 20‐mil PVC geomembrane
Source abstract
Abstract
Abstract In 1971, twenty circular aquaculture ponds were constructed for the W. K. Kellogg Biological Research Station in Hickory Corners, Michigan. The 30.5‐m‐diameter research ponds were lined using a 0.51‐mm‐thick fish‐grade PVC geomembrane. Over the years the ponds became congested with dense, persistent stands of cattails, trees, and other vegetation, which required the ponds to be cleared and relined in September 2000 in order to allow the initiation of new experiments. The lack of holes in the exhumed geomembrane suggests that it resisted biological attack from microorganisms and also root penetration. Laboratory testing shows that the tensile behavior of the nearly 30‐year‐old PVC geomembrane is within current specifications for new 0.51‐mm‐thick PVC geomembranes. Test results also indicate that performing laboratory tests at in‐situ moisture conditions provides a better estimate of the field properties of PVC geomembranes than desiccating the material prior to testing, as is required by ASTM Standard Test Methods. J. Vinyl Addit. Technol. 10:168–173, 2004. © 2004 Society of Plastics Engineers.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Geotechnical Engineering and Soil Stabilization · Landfill Environmental Impact Studies · Microplastics and Plastic Pollution
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (11)
Show source-provided references
1. PVC: A Long History, a Bright Future
2. W. R.MorrisonandA. I.Comer “Use of Geomembranes in Bureau of Reclamation Canals Reservoirs and Dam Rehabilitation ” Report No. REC‐95‐01 U.S. Department of the Interior Bureau of Reclamation Denver (1995).
3. W. R.MorrisonandJ. G.Starbuck “Performance of Plastic Canal Linings ” Report No. REC‐ERC‐84‐1 U.S. Department of the Interior Bureau of Reclamation Denver (1984).
4. M.Hammond G.Hsuan R. E.Mackey andS. B.Levin “The Reexamination of a Nine‐Year‐Old PVC Geomembrane Used in Top Cap Application ”Proceedings of the 31st Annual SWANA Conference pp.365–80 San Jose Calif. (1993).
5. S. B.LevinandM.Hammond “Examination of PVC in a Top Cap Application ”Geosynthetic Testing for Waste Containment Application ASTM STP 1081 pp.369–82(1990).10.1520/STP19044S ↗
6. National Sanitation Foundation (NSF) International Standard 54 Flexible Membrane Liners Ann Arbor Mich.(1993).
7. PVC Geomembrane Institute (PGI) · 2003
8. 10.1680/gein.10.2.56.3707810.1680/gein.10.2.56.37078 ↗
9. T. D.Stark H.Choi andR. W.Thomas “Low Temperature Air Channel Testing of Thermally Bonded PVC Geomembrane Seams ”Geosynthetics International submitted and under review (2004).10.1680/gein.11.6.481.54388 ↗
10. T. D.Stark H.Choi andP. W.Diebel “Influence of Plasticizer Molecular Weight on Plasticizer Retention in PVC Geomembrane ”Geosynthetics International submitted and under review (2004).10.1061/40789(168)22 ↗
11. American Society for Testing and Materials (ASTM) Annual Book of ASTM Standards Geosynthetics 04.09 West Conshohocken Pa.(2000).