Shear resistance and failure modes of nailed joints loaded perpendicular to the grain
Source abstract
Abstract
Shear tests were conducted on nailed joints in wood that were loaded perpendicular to the grain; these joints had 21 specifications depending on different combinations of wood species, nail dimensions, number of nails, and edge distances of the main members, and their effects on the shear resistance of the nailed joints were also investigated. The nailed joints with CN75 nails had higher initial stiffness than the joints with CN50 nails, provided the initial stiffness of nailed joints connected with 3 or 5 nails was not always a simple product of the number of nails and the initial stiffness of nailed joints connected with a nail, and instead depended on the combination of wood species of the main member and nail dimensions. When the edge distance decreased, the maximum load and energy capacity decreased, thereby affecting the energy capacity. The maximum load of the nailed joints with CN75 nails may be smaller than those with CN50 nails depending on the combination of wood species and nail dimensions. When the edge distance of the nailed joints was less than 26 mm, the energy capacity of the nailed joints with CN75 nails was less than or similar to those with CN50 nails.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Wood Treatment and Properties · Mechanical Behavior of Composites · Tree Root and Stability Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. Architectural Institute of Japan (2006) Standard for structural design of timber structures (in Japanese). Architectural Institute of Japan, Tokyo, pp 266–278
2. Hirai T (1987) Basic properties of mechanical wood-joints1. Load–slip curves of nailed wood-plywood joints (1) (in Japanese). Res Bull Hokkaido Univ For 44:1307–1328
3. Kamiya F, Oshiumi S (1989) Lateral loading tests of plywood-lumber nailed joints and proposed allowable lateral capacity (in Japanese). Mokuzai Gakkaishi 35:313–319
4. Hirai T, Ando Y, Ueda K (1991) Lateral resistances and fracture modes of nailed timber joints I (in Japanese). Mokuzai Gakkaishi 37:1157–1166
5. Blass HJ (1994) Characteristic strength of nailed joints. For Prod J 44:33–39
6. Sawata K, Honda K, Hirai T, Koizumi A, Sasaki Y (2010) Effect of member thickness and nail length projecting from main member on shear performance of single shear nailed joints (in Japanese). Mokuzai Gakkaishi 56:317–32510.2488/jwrs.56.317 ↗
7. Soltis LA, Karnasudirdja S, Little JK (1987) Angle to grain strength of dowel-type fasteners. Wood Fiber Sci 19:68–80
8. Girhammar UA, Bovim NI, Källsner B (2004) Characteristics of sheathing-to-timber joints in wood shear walls. In: Proceedings of the 8th world conference on timber engineering, Lahti, Finland, pp 1001–1006
9. Japanese Industrial Standard (2009) Nails (in Japanese). JIS A 5508. Japanese Industrial Standard Association, Tokyo
10. Japanese Industrial Standard (2011) Low carbon steel wires (in Japanese). JIS G 3532. Japanese Industrial Standard Association, Tokyo
11. Japan Ministry of Land, Infrastructure, Transport and Tourism (1981) Notification No. 1100 of the Ministry of Construction
12. Japan Ministry of Land, Infrastructure, Transport and Tourism (2001) Notification No. 1541 of the Ministry of Land, Infrastructure, Transport and Tourism
13. The Japan Wood Research Society (2000) Mechanical joints. In: The Japan Wood Research Society (ed) Manual for wood research experiment (in Japanese). Buneido, Tokyo, pp 244–245
14. Japan 2 × 4 Home Builders Association (2007) Structural design guidelines for wood frame construction (in Japanese). Maruzen, Tokyo, pp 270–272