Density calculation of wood by portable X-ray tube with consideration of penetrating depth
Source abstract
Abstract
A portable X-ray apparatus generates soft X-rays which have a continuous wavelength (wide range). When using continuous wavelength X-rays, the mass attenuation coefficient of the soft X-rays is changed as the penetrating depth in wood increases, unlike monochromatic X-rays which are usually used for medical purposes. In safety inspections of historic buildings, penetrating depth varies in an X-ray radiograph. Computerized tomography (CT) is a powerful tool that helps determine the density information of the inner sections of buildings. Because only portable X-rays can be used in historic buildings and the penetrating depth can vary, the mass attenuation coefficient of wood according to penetrating depth needs to be investigated. Therefore, in this study, we developed a statistical method which takes into account the influence of the penetrating depth on a density calculation made by a portable X-ray apparatus. X-ray tests were conducted on wood specimens of various depths. From the results, a statically determined mass attenuation coefficient (SMAC) ([Formula: see text]), which is the equation of mass attenuation coefficient according to the penetrating depth in wood, was derived to convert radiographs to density radiographs. All projections were converted into density profiles using two methods, average mass attenuation coefficient and SMAC. Based on the density profile for each projection, a density distribution of a cross-section was reconstructed by filtered back projection. Compared with the cases using a consistent mass attenuation coefficient, SMAC provided much higher precision in density prediction than the average mass attenuation coefficient.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Wood Treatment and Properties · Remote Sensing and LiDAR Applications · Wood and Agarwood Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (13)
Show source-provided references
1. National research institute of cultural heritage (2012) Conservation of wooden objects. Pointtech, Daejeon, p 8
2. Schmidt O (2010) Wood and fungi. Springer, Heidelberg, pp 53–54
3. Divos F, Divos P (2005) Resolution of stress wave based acoustic tomography. In: 14th international symposium on nondestructive testing of wood, Shaker, Germany, pp 307–314
4. Nicolotti G, Socco LV, Martinis R, Godio A, Sambuelli L (2003) Application and comparison of three tomographic techniques for detection of decay in tree. J Arboric 29(2):66–78
5. Olson JR, Liu CJ, Tian Y, Shen Q (1988) Theoretical wood densitometry: II. Optimal X-ray energy for wood density measurement. Wood Fiber Sci 20(1):187–196
6. Nakada R, Fujisawa Y, Hirakawa Y (1999) Soft X-ray observation of water distribution in the stem of Cryptomeria japonica D. Don I: general description of water distribution. J Wood Sci 45(3):188–19310.1007/BF01177724 ↗
7. Nakada R, Fujisawa Y, Hirakawa Y (1999) Soft X-ray observation of water distribution in the stem of Cryptomeria japonica D. Don II: types found in wet-area distribution patterns in transverse sections of the stem. J Wood Sci 45(3):194–19910.1007/BF01177725 ↗
8. Macedo A, Vaz CMP, Pereira JCD, Naime JM, Cruvinel PE, Crestana S (2002) Wood density determination by X- and gamma-ray tomography. Holzforschung 56(5):535–54010.1515/HF.2002.082 ↗
9. Lindgren O, Davis J, Wells P, Shadbolt P (1992) Non-destructive wood density distribution measurements using computed tomography. Holzforschung 50(7):295–299
10. Moberg L (2000) Models of internal knot diameter for Pinus sylvestris. Scand J For Res 15(2):177–18710.1080/028275800750014984 ↗
11. Oja J, Temnerud E (1999) The appearance of resin pockets in CT-images of Norway spruce (Picea abies (L.) Karst.). Holzforschung 57(5):400–406
12. Korean society of physics for radiosurgery (2005) Radiation physics (in Korean). Komoonsa, Seoul, pp 209–211
13. Kaelbel EF (1967) Handbook of X-rays. McGraw-Hill, New York, pp 41(3)–41(24)