North American design guidelines for concrete reinforcement and strengthening using FRP: principles, applications and unresolved issues
Source abstract
Abstract
Abstract This paper reports on the North American state-of-the-art in the use of FRP composites in concrete structures. For new construction, FRP bars have been used as the internal reinforcement in concrete members to replace conventional steel rebars for a host of reasons. The principles for design and construction have been established and proposed to industry by the American Concrete Institute (ACI). For repair and upgrade, strengthening of concrete members with externally bonded FRP laminates or near surface mounted (NSM) bars has received remarkable attention. The design and construction principles for use in practice are being finalized by ACI. On the application side, FRP materials have been used in some multi-million dollar projects for strengthening parking garages, multi-purpose convention centers, office buildings and silos. The drivers for this technology are several, but perhaps the most relevant one is the ease of installation. In the repair/upgrade arena (as well as new construction), perhaps one of the most important unresolved question remains that of durability (including fire resistance). Further research and validation is necessary to increase confidence in FRP technology for concrete construction.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Fire effects on concrete materials · Structural Load-Bearing Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (11)
Show source-provided references
1. American Concrete Institute—Committee 440. Guide for the design and construction of concrete reinforced with FRP rebars, ACI 440.1R-01. Farmington Hills, MI, USA: ACI, 2001
2. American Concrete Institute—Committee 318. Building code requirements for structural concrete and commentary, ACI 318-95/R-95. Farmington Hills, MI, USA: ACI, 1995
3. Flexural behavior and design of reinforced concrete using FRP rods10.1061/(ASCE)0733-9445(1993)119:11(3344) ↗
4. Bradberry, TE. Fiber-reinforced-plastic bar reinforced concrete bridge decks, 80th Annual Transportation Research Board, Jan. 9–13, 2001, Washington, DC, CD #01-3247
5. American Concrete Institute—Committee 440. Guide for the design and construction of externally bonded FRP systems for strengthening of concrete structures, Farmington Hills, MI, USA: ACI, 2001, (in print)
6. Contribution of externally bonded FRP to shear capacity of flexural members10.1061/(ASCE)1090-0268(1998)2:4(195) ↗
7. Characterization of FRP rods for near surface reinforcement10.1061/(ASCE)1090-0268(2001)5:2(114) ↗
8. Gold, WJ, Blaszak, GJ, Mettemeyer, M, Nanni, A, Wuerthele, MD., Strengthening dapped ends of precast double tees with externally bonded FRP reinforcement, ASCE Structures Congress 2000, Philadelphia, PA, CD #40492-045-00310.1061/40492(2000)172 ↗
9. Schiebel, S, Parretti R, Nanni A, Huck M. Strengthening and load testing of three bridges in Boone County, MO. ASCE Pract Period Struct Des Constr, 2002 (in print)10.1061/(ASCE)1084-0680(2002)7:4(156) ↗
10. American Association of State Highway and Transportation Officials. Standard specifications for highway bridges, 16th ed., Washington, D.C., 1996:760
11. Cement silo repair and upgrade