journal article·2016-09

Comparative performance of channel and angle shear connectors in high strength concrete composites: An experimental study

M. Shariati, N.H. Ramli Sulong, A. Shariati, A.B.H. Kueh

Publisher page

Abstract

Structural performance of steel-concrete composite structures relies deeply on the characteristics of the shear connectors. Recently, great attention has been focused on the implementation of C-shaped connectors due to numerous advantages when used in composite beams. However, very little information is available in regard to the response of such connectors when embedded in the high strength concrete (HSC). To address this research gap, sixteen experiments on push-out specimens were conducted to compare the performance of channel and angle shear connectors embedded in HSC. The shear resistance and ductility of the connectors were primarily investigated by applying static and cyclic loadings. Results were also compared with the cases when using normal reinforced concrete. Furthermore, the evaluation of the available equations suggested by the American and Canadian codes for estimating these connectors' capacities when using HSC was carried out. In general, channel connectors exhibited 6.8-30.1% more shear strength than those of angle under monotonic loading, and up to 18.5% more when subjected to cyclic loading. Angle connectors were also less ductile than channel connectors and did not satisfy the ductility criteria specified in the codes' requirements. Connector fracture mode of failure was recorded for both connector types.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Load-Bearing Analysis · Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (55)

Show source-provided references
1. Various types of shear connectors in composite structures: a review
2. Flexural strength of steel-concrete composite beams
3. Viest · 1956
4. Recent designs of composite bridges and a new type of shear connectors
5. Behavior of Perfobond rib shear connectors: push-out tests10.1139/l92-001 ↗
6. Behaviour of Perfobond rib shear connectors in composite beams: full-size tests10.1139/l92-028 ↗
7. Oguejiofor · 1994
8. A parametric study of Perfobond rib shear connectors10.1139/l94-063 ↗
9. Full-scale tests of channel shear connectors and composite T-beams
10. Viest · 1952 · 405
11. Dallam · 1968
12. Hiroshi · 1987
13. Investigation of channel shear connectors for composite concrete and steel T-beam
14. Experimental assessment of Perfobond and T-Perfobond shear connectors’ structural response10.1016/j.jcsr.2008.02.011 ↗
15. Computer model of Perfobond connector
16. Behaviour of Perfobond shear connectors at high temperatures10.1016/j.engstruct.2011.05.004 ↗
17. Veŕıssimo · 2006
18. Pashan · 2006
19. Full-scale tests of channel shear connectors and composite T-beams
20. AISC · 2005
21. Behavior of channel shear connectors, Part I: experimental study10.1016/j.jcsr.2008.01.010 ↗
22. Behavior of channel shear connectors, Part II: analytical study10.1016/j.jcsr.2008.01.006 ↗
23. Experimental and analytical study on channel shear connectors in fiber-reinforced concrete10.1016/j.jcsr.2009.04.008 ↗
24. New design equations for channel shear connectors in composite beams10.1139/L09-078 ↗
25. An experimental study on channel type shear connectors10.1016/j.jcsr.2012.02.015 ↗
26. NBC · 2005
27. Behaviour of C-shaped angle shear connectors under monotonic and fully reversed cyclic loading: an experimental study10.1016/j.matdes.2012.04.039 ↗
28. Experimental assessment of angle shear connectors under monotonic and fully reversed cyclic loading in high strength concrete10.1016/j.conbuildmat.2013.11.036 ↗
29. Fatigue energy dissipation and failure analysis of angle shear connectors embedded in high strength concrete10.1016/j.engfailanal.2014.02.017 ↗
30. Kiyomiya · 1986
31. Choi · 2011
32. Fatigue durability of steel-concrete composite slab, MELAB and application to continuous composite steel girder bridge
33. The transferred shear force-relative displacement relationship of the shear connector in steel-concrete sandwich beam and its model10.2208/jsceje.64.122 ↗
34. Ros · 2009 · 1
35. Strength of shear connector by shape steel in composite member with steel and concrete
36. Yamada · 1986
37. Ros · 2011
38. Comparison of behaviour between channel and angle shear connectors under monotonic and fully reversed cyclic loading10.1016/j.conbuildmat.2012.07.050 ↗
39. Recent trends in steel fibered high-strength concrete10.1016/j.matdes.2011.03.030 ↗
40. Experimental study of high strength concrete-filled circular tubular columns under eccentric loading10.1016/j.jcsr.2010.11.017 ↗
41. A simplified method for assessing the ductile behaviour of stud connectors in composite beams with high strength concrete slab10.1016/j.jcsr.2004.01.001 ↗
42. Push-out tests on studs in high strength and normal strength concrete10.1016/0143-974X(94)00036-H ↗
43. Behaviour and design of shear connectors in composite slabs at elevated temperatures10.1016/j.jcsr.2015.08.025 ↗
44. Use of polymer-impregnated concrete permanent form in marine environment: 10-year outdoor exposure in Saudi Arabia10.1016/j.conbuildmat.2013.01.028 ↗
45. Standard test method for compressive strength of cylindrical concrete specimens
46. Effects of curing regimes and cement fineness on the compressive strength of ordinary Portland cement mortars10.1016/j.conbuildmat.2010.11.043 ↗
47. Comparison of different methods for activation of ordinary Portland cement-slag mortars10.1016/j.conbuildmat.2010.06.060 ↗
48. ASTM C150 · 2003
49. The effect of chemical activators on early strength of ordinary Portland cement-slag mortars10.1016/j.conbuildmat.2010.04.006 ↗
50. Behavior of Shear Studs Subjected to Fully Reversed Cyclic Loading10.1061/(ASCE)0733-9445(2003)129:11(1466) ↗
51. Small-scale push-out tests on welded stud shear connectors
52. Test results and design recommendations for composite beams
53. Shear strength of stud connectors in lightweight and normal-weight concrete
54. Parametric studies and preliminary design recommendations on the use of post-installed shear connectors for strengthening non-composite steel bridges
55. Eurocode · 1994