Shear strength of brick masonry walls assembled with different types of mortar
Source abstract
Abstract
Abstract The prediction of masonry shear strength, by direct way, requires appropriate experimental tests on triplets, in line with standard EN 1052-3, or diagonal compression tests on panels according to ASTM 509-2010 and RILEM LUMB6. In the present paper the results of an experimental investigation, carried out by these two types of tests on brick masonry walls assembled with different kinds of mortar are reported. A comparison between the values of the masonry shear strength, calculated applying the three formulas available in literature for the diagonal compression test data, and those obtained by laboratory tests on shear triplets, is presented.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Masonry and Concrete Structural Analysis · Building materials and conservation · Hygrothermal properties of building materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. EC6, Eurocode EN 1996. European Union norm on construction. Design of masonry structures.
2. D.M. del 14 gennaio 2008. Norme Tecniche per le Costruzioni; 2008 [in Italian].
3. EN 1052-3. Methods of test for masonry. Part 3: Determination of initial shear strength. European standard; 2007.
4. EC8, Eurocode EN 1998. European Union norm on construction. Design of structures for earthquake resistance.
5. ASTM E519-2010 · 2010
6. RILEM LUMB6. Diagonal tensile strength tests of small wall specimens (1991)0. Rilem recommendations for the testing and use of constructions materials. RILEM; 1994: p. 488–9.10.1201/9781482271362 ↗
7. The use of the diagonal compression test to identify the shear mechanical parameters of masonry10.1016/j.conbuildmat.2009.11.001 ↗
8. Experimental evaluation of shear and compression strength of masonry wall before and after reinforcement: deep repointing10.1016/j.conbuildmat.2006.11.021 ↗
9. Experimental in-plane behavior of tuff masonry strengthened with cementitious matrix–grid composites10.1061/(ASCE)1090-0268(2006)10:3(223) ↗
10. Shear behavior of masonry panels strengthened by FRP laminates10.1016/S0950-0618(02)00043-0 ↗
11. Diagonal compression testing of FRP-retrofitted unreinforced clay brick masonry wallettes10.1061/(ASCE)CC.1943-5614.0000209 ↗
12. Circolare n.617 del 2 febbraio 2009. Istruzioni per l’Applicazione Nuove Norme Tecniche Costruzioni; 2009 [in italian].
13. Procedure sperimentali per la determinazione delle caratteristiche della muratura
14. Chiostrini · 2000
15. Shear behavior of unreinforced and reinforced masonry panels subjected to in situ diagonal compression tests10.1016/j.conbuildmat.2011.01.009 ↗
16. Experimental study on the determination of strength of masonry walls10.1016/S0950-0618(03)00007-2 ↗
17. Identification of shear parameters of masonry panels through the in situ diagonal compression test10.1080/15583050802138634 ↗
18. Turnašek · 1971
19. EN 1015-11. Methods of test for mortar for masonry. Determination of flexural and compressive strength of hardened mortar. European Standard; 2007.