Abstract

Abstract This paper presents experimental results of tensile strength tests on glass fibre reinforced polymer (GFRP) bars at high temperatures. These results are a part of a comprehensive study on characteristics of GFRP reinforcing bars from different manufacturers. To represent real construction practices, commonly used #5 GFRP reinforcing bars with nominal diameter of 16 mm are studied. The reinforcing bars are selected from three different manufacturers to study the potential differences of various products. Besides conventional steady-state temperature testing, tensile tests are conducted under transient temperature conditions. In transient tests, specimens are loaded before heat exposure. Temperature ranges from 25 to 500 °C are considered for the steady-state tests depending on the type of bar, and for the transient temperature tests, bars are loaded to between 25 and 70% of the bar’s strength at room temperature. The overall conclusion relating to fire performance of GFRP reinforced concrete members is that the three types of GFRP bars that are tested can retain the expected service stress level of 25% of their original tensile strength up to at least 400 °C, and this temperature can be used as the critical temperature in design.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Fire effects on concrete materials · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. CSA (Canadian Standards Association), Design and construction of building components with fiber-reinforced polymers, CSA-S806. Mississauga, ON, Canada, 2012.
2. ACI (American Concrete Institute), Guide Test Methods for Fiber Reinforced Polymers (FRPs) for Reinforcing or Strengthening Concrete Structures, ACI-440.3R, Farmington Hills, MI, 2004.
3. Numerical study of FRP reinforced concrete slabs at elevated temperature10.3390/polym6020408 ↗
4. Lie · 1992
5. Response to fire of concrete structures that incorporate FRP10.1002/pse.198 ↗
6. Calculation of the fire resistance of composite concrete floor and roof slabs10.1007/BF01997259 ↗
7. An experimental study of the mechanical properties of fibre reinforced polymer (FRP) and steel reinforcing bars at elevated temperatures10.1016/j.compstruct.2006.04.069 ↗
8. Behavior of GFRP reinforcing bars subjected to extreme temperatures10.1061/(ASCE)CC.1943-5614.0000092 ↗
9. ACI (American Concrete Institute), Guide for the Design and Construction of Concrete Reinforced with FRP Bars, ACI 440-1R. Detroit, Michigan, 2006.
10. Effect of fire on FRP reinforced concrete members10.1016/S0263-8223(02)00045-4 ↗
11. Fire tests on full-scale FRP reinforced concrete slabs10.1016/j.compstruct.2017.07.060 ↗
12. Smart FRP prestressing tendons: properties and prospects
13. L. Bisby, Fire behaviour of FRP reinforced or confined concrete, PhD thesis, Department of Civil Engineering, Queen’s University, Kingston, ON, 2003:329.
14. Kumahara · 1993 · 138
15. A. Weber, Fire-resistance tests on composite rebars, in: Proceedings of International Conference on FRP Composites in Civil Engineering (CICE2008). Zurich, Switzerland, 2008.
16. H. Hajiloo, J. Gales, M. Noël, M.F. Green, Material Characteristics of Glass Fibre Reinforced Polymer (GFRP) Bars at High Temperature, in: Proceedings of PROTECT‐Fifth International Workshop on Performance, Protection & Strengthening of Structures under Extreme Loading. East Lansing, MI, 2015. pp. 94–104.
17. E. McIntyre, A. Bilotta, L.A. Bisby, E. Nigro, Mechanical Properties of Fibre Reinforced Polymer Reinforcement for Concrete at High Temperature, in: Proceedings of 8th International Conference on Structures in Fire. Shanghai, China, 2014, pp. 1227–1234.
18. Mechanical behaviour of pultruded glass fibre reinforced polymer composites at elevated temperature: Experiments and model assessment10.1016/j.compstruct.2012.10.051 ↗
19. Effect of high temperature on bond strength of FRP rebars10.1061/(ASCE)1090-0268(1999)3:2(73) ↗
20. H. Hajiloo, M.F. Green, N. Bénichou, M. Sultan, Fire Performance of FRP reinforced concrete slabs, in: Proceedings of 7th International Conference on Advanced Composite Materials in Bridges and Structures. Vancouver, Canada, 2016.10.1016/j.compstruct.2017.07.060 ↗
21. CSA (Canadian Standards Association), Specification for fibre-reinforced polymers, CSA-S807, Mississauga, ON, Canada, 2010.
22. Tensile characterization of FRP rods for reinforced concrete structures10.1023/A:1025638310194 ↗
23. D. Johnson, Investigation of Glass Fibre Reinforced Polymer Reinforcing Bars as Internal Reinforcement for Concrete Structures: M.Sc thesis, University of Toronto; 2009.
24. Soil deformation measurement using particle image velocimetry (PIV) and photogrammetry10.1680/geot.2003.53.7.619 ↗
25. Fire performance of sustainable recycled concrete aggregates: mechanical properties at elevated temperatures and current research needs10.1007/s10694-015-0504-z ↗
26. Creep of prestressing steels in fire10.1002/fam.2345 ↗
27. ACI (American Concrete Institute), Guide for the Design and Construction of Concrete Reinforced with FRP Bars, ACI 440-1R, Farmington Hills, MI, 2015.