Independent environmental effects on durability of fiber-reinforced polymer wraps in civil applications: A review
Source abstract
Abstract
Abstract Fiber-reinforced polymers (FRP) are becoming a common method for repair and rehabilitation of civil engineering structures. FRP wraps are common because they are applied to the outer surface of the structure and therefore are easy to apply and cause little disturbance during the repair. FRP may prove to be inexpensive and durable. However the long-term durability of FRP is not comprehensively documented. This article reviews much of the currently published research on the durability of FRP composites, and discusses independent environmental factors.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Smart Materials for Construction
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (46)
Show source-provided references
1. Fatigue behavior of CFRP-strengthened reinforced concrete bridge girders10.1061/(ASCE)1090-0268(2004)8:6(501) ↗
2. Long-term issues related to structural health of FRP bridge decks10.1080/15732480600674060 ↗
3. Durability of concrete reinforced with pultruded fiber reinforced plastic grating
4. Anstice · 1982 · vol. 2
5. Belarbi A, Myers JJ, Chandrashekhara K, Watkins SE, Bae S. Structural integrity of RC columns wrapped with FRP sheet subjected to various environmental conditions including corrosion. RDT 04-021, University of Missouri – Rolla, Rolla, MO; 2004.
6. Corrosion phenomena in glass fibers and glass fiber reinforced thermosetting resins10.1016/0266-3538(85)90040-5 ↗
7. Gap analysis for durability of fiber reinforced polymer composites in civil infrastructure
8. Devalapura · 1998
9. Dutta PK. Investigations of plastic composite materials for highway safety structures. In: Report 98-7, US Army Corps of Engineers Cold Regions Research and Engineering Laboratory, Hanover, NH; 1998.
10. Foster · 2005 · vol. 230
11. Fukuzawa · 2002
12. Gangarao · 1997 · vol. 2
13. Photo-oxidation and photoprotection of the surface resin of a glass fiber-epoxy composite10.1002/app.1977.070210821 ↗
14. Grand AF. Fire evaluations of coatings for glass-reinforced polymeric composites. In: Proceedings of the second international conference and exhibition. fire and materials; 1993. p. 143–59.
15. Green · 1998
16. Gussenhoven · 2005 · vol. 230
17. Haber · 2009
18. Harichandran RS, Baiyasi MI. Repair of corrosion-damaged columns using FRP wraps. RC-1386, Michigan State University, East Lansing, MI; 2000.
19. Higgins C, Dawson MR, Mitchell MM, Sopal G, Senturk AE. Environmental durability of reinforced concrete deck girders strengthened for shear with surface-bonded carbon fiber-reinforced polymer. SPR 652 OTREC-RR-09-09, Oregon State University, Corvallis, OR; 2009.10.15760/trec.21 ↗
20. Flammability testing of flame-retarded epoxy composites and phenolic composites10.1002/(SICI)1099-1018(199701)21:1<41::AID-FAM595>3.0.CO;2-G ↗
21. Assessing the fire performance characteristics of GRP composites
22. Durability of reinforced plastics in liquid environments10.1533/9781845694876.70 ↗
23. On the durability of composite rehabilitation schemes for concrete: use of a peel test10.1023/A:1018591619404 ↗
24. Effect of environmental exposure on the external strengthening of concrete with composites – short term bond durability10.1177/073168449601501202 ↗
25. Comparative durability evaluation of ambient temperature cured externally bonded CFRP and GFRP composite systems for repair of bridges10.1016/j.compositesa.2009.01.011 ↗
26. Karbhari VM, Kaiser H, Navada R, Ghosh K, Lee L. Methods for detecting defects in composite rehabilitated concrete structures. SPR 336, University of California – San Diego, La Jolla, CA; 2005.
27. Klamer · 2005 · vol. 230
28. Kong · 2005 · vol. 230
29. Effect of the properties of the constituents on the fatigue performance of composites: a review10.1016/0010-4361(89)90657-5 ↗
30. The effect of ultraviolet light on mechanical properties of Kevlar 49 composites10.1177/073168448600500103 ↗
31. Composite materials for infrastructure applications: a review
32. Lyon · 1996
33. Fatigue behaviour of fibre–resin composites
34. Moisture penetration into composites under external stress10.1002/pc.750020310 ↗
35. Experimental and numerical study of moisture effects on the bond fracture energy of FRP/concrete joints10.1177/0731684407082952 ↗
36. Pauly CC, Taylor SR, Gomez JP. Environmental durability of graphite/epoxy composites: the combined effects of moisture, cathodic polarization, and stress. VTRC 02-R13, Virginia Transportation Research Council, Charlottesville, VA; 2002.
37. Rahman · 1998 · vol. 2
38. Environmental durability of glass–fiber composites10.1016/0927-796X(94)90002-7 ↗
39. Fire performance studies on glass-reinforced plastic laminates10.1002/fam.810180507 ↗
40. Residual strength of composites during and after fire exposure10.1177/073490419301100305 ↗
41. Steckel GL. Environmental durability of master builders’ CF130 carbon fiber sheet reinforced epoxy composite. ATR-99(7455)-2, The Aerospace Corporation, El Segundo, CA; 1999.
42. Weitsman Y. Moisture in composites: sorption and damage. In: Reifsnider KL, editor. Fatigue of Composite Materials 1991;385–429.10.1016/B978-0-444-70507-5.50013-5 ↗
43. Weitsman YJ. Effects of fluids on polymeric composites – a review. In: Report MAES 95-1.0 CM, The University of Tennessee, Knoxville, TN; 1995.10.21236/ADA297030 ↗
44. Water absorption of resins and composites: II. Diffusion in carbon and glass reinforced epoxies10.1520/CTR10437J ↗
45. Xian · 2010 · vol. 7649
46. Zhang · 1999 · vol. 14