Effect of silica fume and ground pumice on compressive strength and modulus of elasticity of high strength concrete
Source abstract
Abstract
Abstract This paper presents the results of experimental study on compressive strength and secant modulus of elasticity of high strength concrete (HSC) containing different levels of silica fume, ground pumice and silica fume together with ground pumice. Three concrete series with water–binder ratios of 0.25 and a constant total binder content of 450 kg/m 3 were designed. The compressive strength and secant modulus of elasticity of these concrete series were determined. The experimental results clearly reveal the use of silica fume and silica fume together with ground pumice with a very low water–binder ratio in the production of HSC. The highest compressive strength and secant modulus of elasticity are obtained in the concrete mixtures containing 15% silica fume and 15% silica fume together with 5% ground pumice. The relationship between the compressive strength and secant modulus of elasticity of HSC was also discussed. New two equations for modulus of elasticity of concrete containing different levels of silica fume, ground pumice and silica fume together with ground pumice have been proposed. The experimental results of dependent modulus of elasticity of concrete were compared with the results of various equations proposed by some of national building codes and the authors, and also the results of new equations proposed in this study.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Innovative concrete reinforcement materials · Concrete and Cement Materials Research · Concrete Properties and Behavior
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. Advancements in concrete technology
2. Mechanical and durability properties of high performance concretes containing supplementary cementitious materials10.1016/j.conbuildmat.2009.08.045 ↗
3. Aitcin PC. High performance concrete. 1998; USA: Taylor and Francis, p. 624 [ISBN-13: 9780419192701].10.1201/9781420022636 ↗
4. Malhotra · 1996 · vol. 1
5. Mehta · 2006
6. Aitcin PC. High strength concrete: current trends and applications. In: Proceedings of the 5th International Conference on Concrete Engineering and Technology, Kuala Lumpur, Malaysia, 1997. p. 37–46.
7. Fundamental study on the practical use of high performance concrete
8. Development of high performance concrete using silica fume at relatively high water–binder ratios10.1016/S0008-8846(00)00359-8 ↗
9. Effect of silica fume on mechanical properties of high-strength concrete10.1016/S0958-9465(03)00017-9 ↗
10. Correlations between mechanical properties of high-strength concrete10.1061/(ASCE)0899-1561(2002)14:3(230) ↗
11. Model Code · 1990
12. ACI 363-92. State-of-the-art report on high-strength concrete. Manual of concrete practice. Part 1: Materials and general properties of concrete. Detroit: ACI, 1994.
13. NS 3473. Concrete structures–design rules. Norwegian Standardiseringsforbund, Oslo, Norway, 1992.
14. Structural properties of high strength concrete and its implications for precast prestressed concrete10.15554/pcij.11011985.92.119 ↗
15. Mechanical properties of high-performance concrete
16. TS EN-197-1. Cements – Part 1: Compositions and conformity criteria for common cements. Turkish Standards Institute, TSE, Turkey, 2004 [in Turkish].
17. ASTM C 494/C 494M-10a. Standard specification for chemical admixtures for concrete. Book of ASTM Standards. American Society for Testing and Materials, USA, 2010.
18. ASTM C 192. Standard practice for making and curing concrete test specimens in the laboratory. Book of ASTM Standards, vol. 04.02, 2000.
19. TS EN 12350-2. Testing fresh concrete – Part 2: Slump test. TSE, Turkey, 2002 [in Turkish].
20. ASTM C 143. Standard test method for slump of hydraulic cement concrete. Book of ASTM Standards, vol. 04.02, 1988.
21. ASTM C 39/C 39M-12. Standard test method for compressive strength of cylindrical concrete specimens, ASTM. vol. 04.02. West Conshohocken, PA. 2012.
22. TS EN 12390-3. Testing hardened concrete – Part 3: Compressive strength of test specimens. TSE, Turkey, 2002 [in Turkish].
23. ASTM C469-02. Test method for static modulus of elasticity and poisson’s ratio of concrete in compression. Book of ASTM Standards, 2005.
24. TS 3502. Test method for static modulus of elasticity and poisson’s ratio of concrete in compression. TSE, Turkey, 1981 [in Turkish].
25. TS EN 12350-6 Testing fresh concrete – Part 6: Density. TSE, Turkey, 2010 [in Turkish].
26. ASTM C138/C138M-13. Standard test method for density (unit weight), yield, and air content (gravimetric) of concrete. Book of standards, vol. 04.02, 2013.
27. Influence of dry and wet curing conditions on compressive strength of silica fume concrete10.1016/j.buildenv.2004.12.005 ↗
28. High strength concrete containing natural pozzolan and silica fume10.1016/S0958-9465(00)00037-8 ↗
29. Combined effect of silica fume and steel fiber on the mechanical properties of high strength concretes10.1016/j.conbuildmat.2007.04.017 ↗
30. The development of a new method for the proportioning of high-performance concrete mixtures10.1016/j.cemconcomp.2003.09.002 ↗
31. Efficiency of calcined kaolin and silica fume as cement replacement material for strength performance10.1016/j.cemconres.2004.05.051 ↗
32. Effect of silica fume on the mechanical properties of low quality coarse aggregate concrete10.1016/j.cemconcomp.2003.09.003 ↗
33. Prediction of elastic modulus of normal and high strength concrete by artificial neural networks10.1016/j.conbuildmat.2007.04.004 ↗
34. A new way of prediction elastic modulus of normal and high strength concrete-fuzzy logic10.1016/j.cemconres.2005.01.001 ↗