A comparative experimental investigation of concrete, reinforced-concrete and steel-fibre concrete pipes under three-edge-bearing test
Source abstract
Abstract
Three-edge-bearing and crack size measurement tests were carried out on plain concrete, reinforced-concrete, and steel-fibre concrete pipes of 500 mm diameters. The average three-edge-bearing strength and crack size of steel-fibre concrete pipes having steel fibres of RC80/60-BN type at a dosage of 25 kg/m3 turned out to be 82% greater and 47% smaller than those of plain concrete pipes, and 6% greater and 15% smaller than those of reinforced-concrete pipes, respectively. Tests on those steel-fibre concrete pipes having a steel fibres dosage of 40 kg/m3 revealed that a steel fibres dosage of 25 kg/m3 seems to be close to optimum because a 60% increase in the amount of steel fibres engenders only minor improvements. By these findings, steel-fibre concrete pipes are more economical than and mechanically and physically superior to reinforced-concrete pipes. (A) Reprinted with permission from Elsevier.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Geotechnical Engineering and Underground Structures · Structural Load-Bearing Analysis · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. Cracking characteristics of reinforced steel fiber concrete beams under short- and long-term loadings10.1016/1065-7355(95)90013-6 ↗
2. Determination of the first-crack strength and flexural toughness of steel-fiber reinforced concrete10.1016/1065-7355(94)90025-6 ↗
3. Strengthening and toughening mechanisms in microfiber reinforced cementitious composites10.1023/A:1017557015523 ↗
4. ACI, ACI-544.4R-88 Design considerations for steel fibre reinforced concrete, American concrete institute. ACI committee 544; 1988 (Reapproved 1999).
5. TSI, TS-10514 Concrete-steel fibre reinforced-rules for mixing concrete and control. Turkish standards institute, Necatibey Street, 112, Ankara: Turkey; 1992.
6. TSI, TS-821–EN-1916 Concrete pipes and fittings, unreinforced, steel fibre, and reinforced. Turkish standards institute, Necatibey Street, 112, Ankara: Turkey; 1998.
7. A comparative experimental investigation of steel fibre added reinforced concrete beams10.3989/mc.2004.v54.i276.252 ↗
8. Dupont D, Vandewalle L. Bending capacity of steel fibre reinforced concrete (SFRC) beams. International congress on challenges of concrete construction. In: Proceedings of the international conference on innovations and developments in concrete materials and construction, Dundee; 2002. p. 81-90.
9. TSI, TS-EN-197-1 Cements – Part 1: compositions and conformity criteria for common cements. Turkish standards institute, Necatibey Street, 112, Ankara, Turkey; 2004.
10. ASTM, ASTM-C-150-04: Standard specification for portland cement. American society for testing and materials; 2004.
11. TSI, TS-10513 steel fibres for concrete reinforcement. Turkish standards institute, Necatibey Street, 112, Ankara: Turkey; 1992.
12. Institut für Bautechnik, Rohre aus Stahlfaserbeton (Steel-fibre-concrete pipe), Zulassungsbescheid, Anstalt des öffentlichen Rechts: Germany; 1988.
13. BSI, BS-DD-76-Part-2: Draft for development, precast concrete pipes strengthened by chopped zinc-coated steel fibres. British standards institution; 1983.
14. ASTM, ASTM-C76M-03: Standard Specification for reinforced concrete culvert, storm drain, and sewer pipe [metric]. American society for testing and materials; 2003.
15. ASTM, ASTM-C497-03a: standard test methods for concrete pipe, manhole sections, or tile. American society for testing and materials; 2003.
16. ASTM, ASTM-C14M-04: standard specification for concrete sewer, storm drain, and culvert pipe [metric]. American society for testing and materials; 2004.