Designing timber connections for ductility – A review and discussion
Source abstract
Abstract
This paper discusses the design principles of timber connections for ductility with focus on laterally-loaded dowel-type fasteners. Timber connections are critical components of timber structures: not only do they join members, but they also affect load capacity, stiffness, and ductility of the overall system. Moreover, due to the brittle failure behaviour of timber when loaded in tension or shear, they are often the only source of ductility and energy dissipation in the structure in case of overloading, much like a fuse in an electrical circuit. This paper addresses current challenges in connection design for ductility, reviews selected best-practice design approaches to ensure ductility in timber connections, suggests simple performance-based design criteria to design connections for ductility, and aims to stimulate a discussion around potential solutions to implement safe design principles for ductile connections in future design codes and connection testing regimes.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Wood Treatment and Properties · Structural Response to Dynamic Loads · Structural Engineering and Vibration Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (90)
Show source-provided references
1. Connectors and fasteners: Research Needs and Goals
2. The reality of seismic engineering in a modern timber world
3. Popovski, M., & Karacabeyli, E. (2005). Framework for Lateral Load Design Provisions for Engineered Wood Structures in Canada. CIB W18, (August), CIB-W18/38-15-3.
4. Sarti, F., Palermo, A., & Pampanin, S. (2014). Design and Testing of Post-Tensioned Timber Wall Systems. World Conference on Timber Engineering, (August), 2–3.
5. Quasi-Static Cyclic Testing of Two-Thirds Scale Unbonded Posttensioned Rocking Dissipative Timber Walls10.1061/(ASCE)ST.1943-541X.0001291 ↗
6. Experimental Testing of Rocking Cross-Laminated Timber Walls with Resilient Slip Friction Joints10.1061/(ASCE)ST.1943-541X.0001931 ↗
7. Wood-Frame Construction Meeting the Challenges of Earthquakes
8. Cabrero · 2018 · 123
9. Analysis of structural failures in timber structures: Typical causes for failure and failure modes10.1016/j.engstruct.2011.02.045 ↗
10. Köhler, J., Fink, G., & Toratti, T. (2011). Assessment of failures and malfunctions, Publication of COST Action E55-Modelling of the performance of timber structures.
11. General notes on ductility in timber structures10.1016/j.engstruct.2011.07.024 ↗
12. Jockwer, R., G. Fink, and J. Köhler. “Assessment of the Failure Behaviour and Reliability of Timber Connections with Multiple Dowel-Type Fasteners.” Engineering Structures 172 (October 1, 2018): 76–84. https://doi.org/10.1016/j.engstruct.2018.05.081.10.1016/j.engstruct.2018.05.081 ↗
13. Consideration of plasticity within the design of timber structures due to connection ductility10.1016/j.engstruct.2011.08.013 ↗
14. The challenges for designers of tall timber buildings
15. Capacity design of traditional and innovative ductile connections for earthquake-resistant CLT structures10.1007/s10518-018-00536-6 ↗
16. A methodology to determine the seismic low-cycle fatigue strength of timber connections10.1016/j.conbuildmat.2019.117026 ↗
17. Low cycle ductile performance of screws used in timber structures10.1016/j.conbuildmat.2019.05.087 ↗
18. Ductility of timber joints under static and cyclic loads10.1680/stbu.10.00017 ↗
19. Boughton · 2013
20. Pei, S., Lindt, J. Van De, Barbosa, A., Berman, J., Dolan, J., Zimmerman, R. B., … Ryan, K. (2018). Full-Scale Shake Table Test of Mass-Timber Building With Resilient Post-Tensioned Rocking Walls. World Conference on Timber Engineering, 8–13.
21. Full-Scale Shake Table Testing of Cross-Laminated Timber Rocking Shear Walls with Replaceable Components10.1061/(ASCE)ST.1943-541X.0002388 ↗
22. Cabrero, J.M., Stepinac, M., Ranasinghe, K., & Kleiber, M. (2018). Results from a questionnaire for practitioners about the connections chapter of Eurocode 5. Sandhaas, C., Munch-Andersen, J., & Dietsch, P. (Eds.). Design of Connections in Timber Structures.10.1016/j.engstruct.2018.05.058 ↗
23. Blaß H.J., Biehnhaus A., Krämer V. (2000): Effective bending capacity of dowel-type fasteners. In: Proc. of the CIB-W18 Meeting 33, Delft, The Netherlands, Paper No. CIB-W18/33-7-5.
24. Jorissen · 1998
25. Follesa, M., Fragiacomo, M., Casagrande, D., Tomasi, R., Piazza, M., Vassallo, D., & Rossi, S. (2016). The new version of chapter 8 of Eurocode 8. WCTE 2016 - World Conference on Timber Engineering.
26. Follesa, M., Fragiacomo, M., Casagrande, D., Tomasi, R., Piazza, M., Vassallo, D., … Rossi, S. (2018). The new provisions for the seismic design of timber buildings in Europe. Engineering Structures, 168(December 2017), 736–747. https://doi.org/10.1016/j.engstruct.2018.04.090.10.1016/j.engstruct.2018.04.090 ↗
27. AS 1720.1-2010 (2010). Timber structures Part 1 : Design methods. Standards Australia Limited, GPO Box 476, Sydney, NSW 2001, Australia. ISBN 978 0 7337 9429 2.
28. Development of Limit States Design Method for Timber Joints with Dowel Type Fasteners Part 2 Comparison of Experimental Results with European Yield Model (EYM) Predictions
29. SIA · 2012
30. 1975
31. Ottenhaus, L. M., Li, M., & Smith, T. (2020). Analytical Derivation and Experimental Verification of Overstrength Factors of Dowel-type Timber Connections for Capacity Design. Journal of Earthquake Engineering, 00(00), 1–15. https://doi.org/10.1080/13632469.2020.1781711.10.1080/13632469.2020.1781711 ↗
32. Structural performance of dowelled cross-laminated timber hold-down connections with increased row spacing and end distance10.1016/j.conbuildmat.2020.121595 ↗
33. Stehn L, Björnfot A. (2002). Comparison of different ductility measurements for a nailed steel-to-timber connection. In: Proceedings of the 7th world conference on timber engineering WCTE 2002.
34. Flatscher, G. (2017). Evaluation and approximation of timber connection properties for displacement-based analysis of CLT wall systems. PhD Thesis. TU Graz.
35. Ottenhaus, L.-M. (2019). Seismic Performance of Dowel-Type Connections in Tall Timber Buildings. PhD Thesis. University of Canterbury.
36. Jockwer, R., and A. Jorissen. 2018. ‘Load-Deformation Behaviour and Stiffness of Lateral Connections with Multiple Dowel Type Fasteners’. In Proc. of the INTER Meeting 51, 51-7–7. Tallinn, Estonia: Timber Scientific Publishing, Karlsruhe, Germany.
37. Smith, I., Asiz, A., Snow, M., & Chui, Y. H. (2006). Possible Canadian / ISO Approach to Deriving Design Values From Test Data. CIB W18 Meeting, (39).
38. Muñoz W, Mohammad M, Salenikovich A, Quenneville P. (2008). Need for a harmonized approach for calculations of ductility of timber assemblies. In: Proceedings of the meeting 41 of the working commission W18-timber structures. CIB. 2008.
39. Karacabeyli E, Ceccotti A. Nailed wood-frame shear walls for seismic loads: Test results and design considerations. Struct Eng World Wide 1998; Paper ref. T207-6.
40. Yasumura M, Kawai N. (1998). Estimating seismic performance of wood-framed structures. In: Proceedings of 1998 IWEC Switzerland. vol. 2. p. 564–71.
41. Howtec · 2017
42. Foliente G. C. (1996) Issues in seismic performance testing and evaluation of timber structural systems. In: Proceedings of the 1996 international timber engineering conference. vol. 1. p. 1.29–.36.
43. ASTM D5764-97a. (2013). Standard Test Method for Evaluating Dowel-Bearing Strength of Wood and Wood-Based Products. https://doi.org/10.1520/D5764-97AR13.2.
44. EN 12512:2001 · 2001
45. Parameterization equations for the nonlinear connection slip applied to the anisotropic embedment behavior of wood10.1016/j.compositesb.2018.01.003 ↗
46. Schweigler, M., Bader, T. K., Bocquet, J. F., Lemaître, R., & Sandhaas, C. (2019). Embedment test analysis and data in the context of phenomenological modeling for dowelled timber joint design. International Network on Timber Engineering Research (INTER) - Meeting Fifty-Two, Tacoma (US), INTER / 52-07-8, 1–17.
47. Displacement-Based Seismic Design of Structures10.1193/1.2932170 ↗
48. Structural performance of large-scale dowelled CLT connections under monotonic and cyclic loading10.1016/j.engstruct.2018.09.002 ↗
49. Overstrength of dowelled CLT connections under monotonic and cyclic loading10.1007/s10518-017-0221-8 ↗
50. Chuang, W. C., & Spence, S. M. J. (2019). An efficient framework for the inelastic performance assessment of structural systems subject to stochastic wind loads. Engineering Structures, 179(November 2018), 92–105. https://doi.org/10.1016/j.engstruct.2018.10.039.10.1016/j.engstruct.2018.10.039 ↗
51. Probabilistic performance assessment of inelastic wind excited structures within the setting of distributed plasticity
52. EN 26891:1991 (1991). Timber Structures - Joints Made with Mechanical Fasteners - General Principles for the Determination of Strength and Deformation Characteristics. European Committee for Standardization, Brussels.
53. Mode Cross-Over and Ductility of Dowelled LVL and CLT Connections under Monotonic and Cyclic Loading10.1061/(ASCE)ST.1943-541X.0002074 ↗
54. Ductility of dowelled and nailed CLT and LVL connections under monotonic and cyclic loading
55. Rodd · 1973
56. An experimental and numerical study of the effect of friction in single dowel jointsExperimentelle und rechnerische Untersuchung des Einflusses von Reibung in Verbindungen mit einem Stabdübel10.1007/s00107-008-0267-z ↗
57. New criteria for the determination of the parallel-to-grain embedment strength of wood10.1016/j.conbuildmat.2018.03.127 ↗
58. Trayer · The bearing strength of wood under bolts · 1932 · Vol. 326 · 1932
59. AS/NZS ISO 10984.2:2015. (2015). Timber structures—Dowel-type fasteners Part 2: Determination of embedding strength. Jointly published by SAI Global Limited under licence from Standards Australia Limited, GPO Box 476, Sydney, NSW 2001 and by Standards New Zealand, Private Bag 2439, Wellington 6140.
60. EN 383:2007 · 2007
61. Discussion of testing and evaluation methods for the embedment behaviour of connections
62. Influence of number of layers on embedment strength of dowel-type connections for glulam and cross-laminated timber10.1016/j.engstruct.2018.09.005 ↗
63. Embedment Strength of New Zealand Cross Laminated Timber
64. Effective bending capacity of dowel-type fasteners
65. Load-carrying capacity of dowelled connections
66. AS/NZS ISO 10984.1:2015. (2015). Timber structures—Dowel-type fasteners Part 1: Determination of yield moment. Jointly published by SAI Global Limited under licence from Standards Australia Limited, GPO Box 476, Sydney, NSW 2001 and by Standards New Zealand, Private Bag 2439, Wellington 6140.
67. Experimental Analysis of Plug Shear Failure in Timber Connections with Small Diameter Fasteners Loaded Parallel-to-Grain10.1016/j.engstruct.2020.111766 ↗
68. On the need of distinguishing ductile and brittle failure modes in timber connections with dowel-type fasteners10.1016/j.engstruct.2021.112496 ↗
69. Proposal for a mechanics-based bolted connection design approach for AS1720.110.1080/13287982.2009.11465022 ↗
70. Cabrero, J. M., & Yurrita, M. (2018). Performance assessment of existing models to predict brittle failure modes of steel-to-timber connections loaded parallel-to-grain with dowel-type fasteners. Engineering Structures, 171(November 2017), 895–910. https://doi.org/10.1016/j.engstruct.2018.03.037.10.1016/j.engstruct.2018.03.037 ↗
71. A probabilistic study of brittle failure in dowel-type timber connections with steel plates loaded parallel to the grain10.1080/17480272.2019.1645206 ↗
72. Yurrita, M., & Cabrero, J. M. (2020b). Effective thickness of timber elements for the evaluation of brittle failure in timber-to-steel connections with large diameter fasteners loaded parallel-to-grain at the elastic range: A new method based on a beam on elastic foundation. Engineering Structures, 209(December 2019), 109959. https://doi.org/10.1016/j.engstruct.2019.109959.10.1016/j.engstruct.2019.109959 ↗
73. New design model for brittle failure in the parallel-to-grain direction of timber connections with large diameter fasteners
74. New design model for splitting in timber connections with one row of fasteners loaded in the parallel-to-grain direction
75. Novis, S. A. L., Jacks, J., & Quenneville, P. (2016). Predicting the Resistance and Displacement of Timber Bolted Connections. WCTE 2016 - World Conference on Timber Engineering.
76. Strength of Timber Connections under Potential Failure Modes: An Improved Design Procedure10.1016/j.conbuildmat.2014.02.049 ↗
77. Brittle Failure in the Parallel-to-Grain Direction of Timber Connections with Small Diameter Dowel-Type Fasteners: A New Design Model for Plug Shear10.1016/j.engstruct.2021.112450 ↗
78. Blaß H. (1990) Load distribution in nailed joints, in: CIB-W18 Timber structures, Lisbon, Portugal, Paper 23–7–2; 1990.
79. Bader, T. K., Bocquet, J.-F., Schweilger, M., Lemaitra, R. (2018) Numerical modeling of the load distribution in multiple fastener connections. Sandhaas, C., Munch-Andersen, J., & Dietsch, P. (Eds.). Design of Connections in Timber Structures.
80. EN 1995-1-1:2004/2008. (2004). Eurocode 5: Design of timber structures — Part 1-1: General — Common rules and rules for buildings. https://doi.org/10.1680/cien.2001.144.6.39.10.1680/cien.2001.144.6.39 ↗
81. Resistance of Connections in Cross-Laminated Timber (CLT) Under Block Tear-Out Failure Mode
82. New design approach for controlling brittle failure modes of small-dowel-type connections in Cross-laminated Timber (CLT)10.1016/j.conbuildmat.2015.09.049 ↗
83. Early experimental investigations on slotted-in steel plate connections with self-perforating dowels in CLT10.1080/17480272.2019.1626482 ↗
84. Jockwer, R. “Impact of Varying Material Properties and Geometrical Parameters on the Reliability of Shear Connections with Dowel Type Fasteners.” In Proc. of the INTER Meeting 3/Paper 49-7-1. Graz, Austria, 2016.
85. Köhler · 2006 · 16378
86. Ranasinghe, K., Cabrero, J. M., Stepinac, M., & Kleiber, M. (2018). Practitioners’ Opinions About the En 1995 – Results From Comprehensive Online Survey. World Conference in Timber Engineering 2018.
87. A holistic framework for designing for structural robustness in tall timber buildings10.1016/j.engstruct.2020.111432 ↗
88. Experimental Study of Disproportionate Collapse Prevention Mechanisms for Mass-Timber Floor Systems10.1061/(ASCE)ST.1943-541X.0002485 ↗
89. Cheng, X., Gilbert, B. P., Guan, H., Underhill, I. D., & Karampour, H. (2021). Experimental dynamic collapse response of post-and-beam mass timber frames under a sudden column removal scenario. Engineering Structures, 233(June 2020), 111918. https://doi.org/10.1016/j.engstruct.2021.111918.10.1016/j.engstruct.2021.111918 ↗
90. Lyu, C. H., Gilbert, B. P., Guan, H., Underhill, I. D., Gunalan, S., & Karampour, H. (2021). Experimental study on the quasi-static progressive collapse response of post-and-beam mass timber buildings under an edge column removal scenario. Engineering Structures, 228(October 2020), 111425. https://doi.org/10.1016/j.engstruct.2020.111425.10.1016/j.engstruct.2020.111425 ↗