journal article·2016-03

Experimental study on compressive behavior of damaged normal- and high-strength concrete confined with CFRP laminates

Yongchang Guo, Jianhe Xie, Zhihong Xie, Jian Zhong

Publisher page

Abstract

Abstract In recent years, it has become increasingly common to strengthen concrete structures by bonding carbon fibre reinforced polymer (CFRP) laminates to the external surfaces of the members. Extensive studies on the mechanical behavior of CFRP-confined concrete have been conducted. However, most of these studies focused on the use of CFRP sheets to confine intact normal strength concrete (NSC), while the behavior of CFRP-confined high strength concrete (HSC) is much less understood. An experimental study was conducted to investigate the axial compressive behavior of CFRP-confined damaged concrete containing NSC and HSC in this study. A total of 60 cylindrical specimens with the dimensions of 150 mm × 300 mm (diameter × height) were tested under axial compression. The test parameters included two types of concrete, two levels of damage to the specimens and three amounts of CFRP wrapping. The effects of these parameters on the failure mode, the ultimate conditions, the energy dissipation capacity and the stress–strain relationship of the CFRP-confined specimens were analyzed. The existing ultimate strength and axial strain models were assessed against the experimental datasets and the performance of these models were discussed. The results showed that CFRP confinement can greatly improve the ultimate strength and axial strain of both intact and damaged concrete specimens. For small amounts of CFRP reinforcement, the pre-existing damage had a significant effect on the compressive performance of CFRP-confined NSC but a smaller effect on that of CFRP-confined HSC. Greater amounts of CFRP considerably improved the ultimate strength and axial strain of the specimens and eliminated the effect of the pre-existing concrete damage. In addition, the results of this model assessment indicated the need to develop more accurate stress–strain models for FRP-confined damaged NSC or HSC.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (42)

Show source-provided references
1. American Concrete Institute, Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures (ACI 440), Farmington Hills, Michigan, 2008.
2. Experimental study on rehabilitation of corrosion damaged reinforced concrete beams with carbon fiber reinforced polymer10.1016/j.conbuildmat.2012.09.023 ↗
3. Behavior of damaged and undamaged concrete strengthened by carbon fiber composite sheets10.12989/sem.2002.13.1.075 ↗
4. Maximum usable strain of FRP-confined concrete10.1016/j.conbuildmat.2015.03.017 ↗
5. Experimental investigation of slender circular RC columns strengthened with FRP composites10.1016/j.conbuildmat.2014.07.053 ↗
6. Cyclic and monotonic behavior of FRP confined concrete rectangular prisms with different aspect ratios10.1016/j.conbuildmat.2012.10.008 ↗
7. Experimental and numerical investigation of size effects in FRP-wrapped concrete columns10.1016/j.conbuildmat.2011.10.025 ↗
8. Behavior of square and circular columns strengthened with aramidic or carbon fibers10.1016/j.conbuildmat.2011.03.007 ↗
9. Effect of cross-sectional aspect ratio on the strength of CFRP-confined rectangular concrete columns10.1016/j.engstruct.2009.08.012 ↗
10. Experimental study of FRP confined concrete cylinders10.1016/j.engstruct.2005.11.006 ↗
11. Compressive behavior of concrete externally confined by composite jackets. Part I: experimental study10.1016/j.conbuildmat.2004.05.012 ↗
12. Compression strength of pre-damaged concrete cylinders reinforced by non-adhesive filament wound composites10.1016/S1359-835X(03)00250-1 ↗
13. Repair effects and acoustic emission technique-based fracture evaluation for predamaged concrete columns confined with fiber-reinforced polymers10.1061/(ASCE)CC.1943-5614.0000309 ↗
14. Confinement of damaged and nondamaged structural concrete with FRP and TRC sleeves10.1061/(ASCE)1090-0268(2007)11:5(514) ↗
15. Comparative behavior under compression of concrete columns repaired by fiber reinforced polymer (FRP) jacketing and ultra high performance fiber reinforced concrete (UHPFRC)10.1080/01694243.2014.966885 ↗
16. FRP composites strengthening of concrete columns under various loading conditions10.3390/polym6041040 ↗
17. FRP-confined concrete in circular sections: review and assessment of stress–strain models10.1016/j.engstruct.2012.06.010 ↗
18. Stress–strain relationship of confined and unconfined concrete
19. Complete triaxial stress–strain curves of high-strength concrete10.1061/(ASCE)0899-1561(2001)13:3(209) ↗
20. Influence of concrete strength and confinement method on axial compressive behavior of FRP confined high- and ultra high-strength concrete10.1016/j.compositesb.2013.02.017 ↗
21. Influence of concrete strength on confinement effectiveness of fiber-reinforced polymer circular jackets
22. Behavior of normal and high-strength concrete cylinders confined with E-glass/epoxy composite laminates10.1016/j.compositesb.2006.06.021 ↗
23. Experimental and computational studies on high-strength concrete circular columns confined by aramid fiber-reinforced polymer sheets
24. Experimental study of normal and high-strength concrete confined with fiber-reinforced polymers10.1061/(ASCE)CC.1943-5614.0000116 ↗
25. Compressive behaviour of concrete externally confined by composite jackets. Part A: experimental study10.1016/j.conbuildmat.2004.05.012 ↗
26. Behavior and modeling of confined high-strength concrete10.1061/(ASCE)CC.1943-5614.0000070 ↗
27. Axial compressive behavior of circular high-strength concrete-filled FRP tubes10.1061/(ASCE)CC.1943-5614.0000410 ↗
28. The experimental studies on behavior of ultrahigh-performance concrete confined by hybrid fiber-reinforced polymer tubes
29. Strengthening effects with carbon fiber sheet for concrete column
30. Analytical model for circular normal and high-strength concrete columns confined with FRP10.1061/(ASCE)CC.1943-5614.0000115 ↗
31. Stress–strain model for concrete confined by FRP composites10.1016/j.compositesb.2006.07.020 ↗
32. Confinement model for FRP-confined high-strength concrete10.1061/(ASCE)CC.1943-5614.0000376 ↗
33. Confinement model for FRP confined normal- and high-strength concrete circular columns10.1016/j.conbuildmat.2014.06.036 ↗
34. GB50608-2010, Technical Code for Infrastructure Application of FRP Composites, China Metallurgical Construction Association, Beijing, China, 2011.
35. Evaluation of strains at peak stresses in concrete: a three-phase composite model approach10.1016/S0958-9465(98)00012-2 ↗
36. Ultimate condition of fiber reinforced polymer-confined concrete10.1061/(ASCE)1090-0268(2004)8:6(539) ↗
37. Comparison of confinement models for fiber reinforced polymer-wrapped concrete
38. Theoretical model for fiber reinforced polymer-confined concrete10.1061/(ASCE)1090-0268(2007)11:2(201) ↗
39. Behavior of concrete cylinders confined by a carbon composite III: deformability and the ultimate axial strain10.1007/s11029-006-0040-5 ↗
40. Closed form constitutive relationship for concrete filled FRP tubes under compression10.1016/j.conbuildmat.2005.08.004 ↗
41. Refinement of a design-oriented stress–strain model for FRP-confined concrete10.1061/(ASCE)CC.1943-5614.0000012 ↗