Behaviour of concrete-filled steel-tube columns strengthened with high-strength CFRP textile grid-reinforced high-ductility engineered cementitious composites
Source abstract
Abstract
Abstract In this study, a new strengthening technique was developed to improve the mechanical behaviour, fire resistance, and corrosion resistance of concrete-filled steel tubes (CFSTs). The proposed technique involved the strengthening of CFST columns using high-strength carbon fibre-reinforced polymer (CFRP) textile grid-reinforced high-ductility engineered cementitious composite (ECC). The behaviour of composite columns under axial compression was investigated. A total of 30 specimens, which comprised 27 strengthened columns and three un-strengthened control specimens, were subjected to experimental tests. The parameters considered for the tests were the number of CFRP textile grid layers, diameter–thickness ratio, and concrete strength. The experimental results showed that strengthened specimens exhibited a better strengthening effect than the control specimens. Unlike brittle failure, which occurred when the CFST columns were strengthened with FRP sheets, the ductility of the columns strengthened with CFRP textile grid-reinforced ECC was as good as that of CFSTs because of the occurrence of progressive failure. The in-filled concrete, whose strength increased owing to the confinement of the CFRP textile grids, resisted most of the loads on the strengthened columns. Based on different models, equations were derived to predict the load-bearing capacity, and the predicted results showed high accuracy.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (40)
Show source-provided references
1. Developments and advanced applications of concrete-filled steel tubular (CFST) structures: Members10.1016/j.jcsr.2014.04.016 ↗
2. Behaviour of square CFST beam-columns under combined sustained load and corrosion: Experiments10.1016/j.tws.2018.12.037 ↗
3. Post-fire residual strength of steel tubular T-joint with concrete-filled chord10.1016/j.jcsr.2017.09.015 ↗
4. Electrochemical performance of corroded reinforced concrete columns strengthened with fiber reinforced polymer10.1016/j.compstruct.2018.09.028 ↗
5. Applications of FRP Composites in Concrete Columns10.1260/1369433041653552 ↗
6. Confined Concrete-Filled Tubular Columns10.1061/(ASCE)0733-9445(2005)131:3(488) ↗
7. Analytical Model of Circular CFRP Confined Concrete-Filled Steel Tubular Columns under Axial Compression10.1061/(ASCE)CC.1943-5614.0000056 ↗
8. FRP-confined circular concrete-filled steel tubular columns under cyclic axial compression10.1016/j.jcsr.2013.11.003 ↗
9. Cyclic lateral response of FRP-confined circular concrete-filled steel tubular columns10.1016/j.jcsr.2016.05.006 ↗
10. Experimental study on CFST members strengthened by CFRP composites under compression10.1016/j.jcsr.2011.10.014 ↗
11. Axial Loading Behavior of CFRP Strengthened Concrete-Filled Steel Tubular Stub Columns10.1260/136943307780150814 ↗
12. FRP-Confined Circular Concrete-Filled Thin Steel Tubes under Axial Compression10.1061/(ASCE)CC.1943-5614.0000217 ↗
13. Y.Y. Lu, N. Li, S. Li, Behavior of FRP-Confined Concrete-Filled Steel Tube Columns, Polymers-Basel, 6 (2014) 1333-1349.10.3390/polym6051333 ↗
14. Performance in Fire of Small-Scale CFRP Strengthened Concrete Beams10.1061/(ASCE)1090-0268(2006)10:6(503) ↗
15. The combined effects of wet-dry cycles and sustained load on the bond behavior of FRP-concrete interface10.1002/pc.24785 ↗
16. Comparison between Organic and Inorganic Matrices for RC Beams Strengthened with Carbon Fiber Sheets10.1061/(ASCE)1090-0268(2007)11:5(507) ↗
17. Comparative Study of Different Cement-Based Inorganic Pastes towards the Development of FRIP Strengthening Technology10.1061/(ASCE)CC.1943-5614.0000420 ↗
18. Strengthening of Concrete Structures with Textile Reinforced Mortars: State-of-the-Art Review10.1061/(ASCE)CC.1943-5614.0000882 ↗
19. Behaviour of fibre reinforced cementitious matrix strengthened concrete columns under eccentric compression loading10.1016/j.matdes.2013.09.008 ↗
20. Effects of confinement level, cross-section shape and corner radius on the cyclic behavior of CFRCM confined concrete columns10.1016/j.conbuildmat.2014.01.035 ↗
21. Concrete columns confined with fibre reinforced cementitious mortars: Experimentation and modelling10.1016/j.conbuildmat.2013.11.048 ↗
22. Concrete confinement with a cement based high strength composite material10.1016/j.compstruct.2013.10.037 ↗
23. Effect of eccentric compression loading on the strains of FRCM confined concrete columns10.1016/j.conbuildmat.2014.03.007 ↗
24. Textile reinforced concrete for strengthening of RC columns: A contribution to resource conservation through the preservation of structures10.1016/j.conbuildmat.2016.11.133 ↗
25. A comparison between the use of FRP, FRCM and HPM for concrete confinement10.1016/j.compositesb.2018.12.111 ↗
26. Steady-state and multiple cracking of short random fiber composites
27. Matrix design for pseudo-strain-hardening fibre reinforced cementitious composites10.1007/BF02473191 ↗
28. Durable repair of aged infrastructures using trapping mechanism of engineered cementitious composites10.1016/S0958-9465(97)00026-7 ↗
29. Tailoring ECC for Special Attributes: A Review10.1007/s40069-012-0018-8 ↗
30. Repair of fire-damaged RC slabs with basalt fabric-reinforced shotcrete10.1016/j.conbuildmat.2018.07.043 ↗
31. Flexural behaviour of reinforced concrete beams strengthened with a composite reinforcement layer: BFRP grid and ECC10.1016/j.conbuildmat.2016.04.038 ↗
32. Flexural strengthening of RC beams with CFRP grid-reinforced ECC matrix10.1016/j.compstruct.2018.01.048 ↗
33. Experimental investigation of textile reinforced engineered cementitious composite (ECC) for square concrete column confinement10.1016/j.conbuildmat.2018.04.161 ↗
34. Using textile reinforced engineered cementitious composite for concrete columns confinement10.1016/j.compstruct.2018.11.093 ↗
35. JSCE, Recommendations for design and construction of high performance fiber reinforced cement composite with multical fine cracks (HPFRCC), 2008.
36. Structural Upgrade Using Basalt Fibers for Concrete Confinement10.1061/(ASCE)CC.1943-5614.0000114 ↗
37. Ministry of Housing and Urban-Rural Development of the People's Republic of China (MOHURD), Technical code for concrete filled steel tubular structures, GB 50936-2014, China Architecture & Building Press, Beijing, 2014.
38. Confined Concrete Elements with Cement-Based Composites: Confinement Effectiveness and Prediction Models10.1061/(ASCE)CC.1943-5614.0000755 ↗
39. Concrete Confinement with Textile-Reinforced Mortar Jackets
40. ACI, Guide to Design and Construction of Externally Bonded Fabric-Reinforced Cementitious Matrix (FRCM) systems for Repair and Strengthening Concrete and Masonry Structures. ACI 549.4R-13. USA: American Concrete Institute, 2013.