journal article·2023-09

Laboratory full-scale test on the bond property of GFRP anchor to concrete

Gan Sun, Nan Yan, Xiaoyu Bai, Junwei Liu, Dongshuai Hou, Songkui Sang, Mingyi Zhang, Pan Wang, Desheng Jing

Publisher page

Abstract

Glass fiber reinforced polymer (GFRP) bolt, which has excellent mechanical properties and corrosion resistance, is gradually replacing metal bolt in rock and soil anchoring, compared with traditional reinforced bolts and other composite materials with high cost. In the current study, the influence of anchorage length and anchorage mode on the bonding property of bolt and concrete was investigated, and the stress mechanism of glass fiber bolt was analyzed based on the tensile test of a full-size laboratory sample. The results show that the failure modes of GFRP anti-floating anchor were pull-out failure and fracture failure, the ultimate bearing capacity of mechanical anchorage was noted as 1.08–1.24 times that of linear anchorage. Under the same anchorage method, with the increase of anchorage length, the relative displacement and the proportion of load bearing in the easing section of the bolt load–displacement curve decreased; thus, the load–displacement curve of the anchor in the form of mechanical anchorage was smoother. With the increase of load, the main load bearing mode of the bolt-concrete interface changed from the interface friction force and chemical adhesive force to the mechanical bite force, and then the interface concrete was broken, and the concrete no-acting zone was transformed into the acting zone until the bolt was damaged. Anchor had a maximum anchorage length beyond which the bearing capacity of the anchors increased minimally. Comparing the calculation formulas of anchor length under different national standards, it was suggested to use Chinese or European standards to calculate anchor length.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Geotechnical Engineering and Underground Structures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Durability of GFRP bars: a critical review of the literature10.1002/pse.205 ↗
2. Pultruded GFRP square hollow columns with bolted sleeve joints under eccentric compression10.1016/j.compositesb.2018.11.001 ↗
3. Bond mechanism and bond strength of GFRP bars to concrete: a review10.1016/j.compositesb.2016.04.068 ↗
4. Fundamental mechanisms of bonding of glass fiber reinforced polymer reinforcement to concrete10.1016/j.conbuildmat.2010.12.054 ↗
5. Effect of temperature on the bond behaviour of GFRP bars in concrete10.1016/j.compositesb.2019.107602 ↗
6. Mechanical properties and bond strength degradation of GFRP and steel rebars at elevated temperatures10.1016/j.conbuildmat.2018.06.203 ↗
7. Long-term bond performance of GFRP bars in concrete under temperature ranging from 20 C to 80 C10.1016/j.conbuildmat.2009.12.040 ↗
8. A model for the bond-slip of a GFRP bar in concrete10.1016/j.engstruct.2017.05.034 ↗
9. Stress monitoring on GFRP anchors based on fiber Bragg grating sensors10.3390/s19071507 ↗
10. Critical embedment length and bond strength of fully encapsulated rebar rockbolts10.1016/j.tust.2016.06.007 ↗
11. Experimental study of bond-slip of GFRP bars in concrete under sustained loads10.1016/j.compositesb.2015.01.006 ↗
12. Interfacial bond strength of glass fiber reinforced polymer bars in high-strength concrete10.1016/j.compositesb.2007.03.008 ↗
13. Slip distribution model along the anchorage length of prestressing strands10.1016/j.engstruct.2013.11.032 ↗
14. Local bond-slip response of GFRP rebar in ultra-high-performance fiber-reinforced concrete10.1016/j.compstruct.2014.09.055 ↗
15. Bond of GFRP bars in concrete: experimental study and analytical interpretation10.1061/(ASCE)1090-0268(2006)10:5(381) ↗
16. Remarks on bond of GFRP rebars and concrete10.1016/j.compositesb.2016.03.012 ↗
17. Strength degradation of glass fiber reinforced polymer bars subjected to reversed cyclic load10.1007/s11223-014-9541-y ↗
18. Physical, mechanical, and durability characterization of preloaded GFRP reinforcing bars10.1061/(ASCE)CC.1943-5614.0000104 ↗
19. Combined effects of saline solution and moist concrete on long-term durability of GFRP reinforcing bars10.1016/j.conbuildmat.2012.08.021 ↗
20. Durability of basalt fibers and composites in corrosive environments10.1177/0021998314526628 ↗
21. Creep behavior and tensile properties of GFRP bars under sustained service loads
22. Evaluation of concrete structures reinforced with fiber reinforced polymers bars: a review
23. Tensile characterization of glass FRP bars10.1016/j.compositesb.2004.05.004 ↗
24. Nacer · 2008
25. A review on machinability of carbon fiber reinforced polymer (CFRP) and glass fiber reinforced polymer (GFRP) composite materials10.1016/j.dt.2018.02.001 ↗
26. Load-bearing characteristics of fibreglass uplift anchors in weathered rock10.1680/jgeen.18.00195 ↗
27. YB/T4659-2018, Technical specification for anti-floating anchors[S]. Beijing: Metallurgical Industry Press, 2018.
28. Post-installed reinforcement connections at ultimate and serviceability limit states10.1002/suco.201300094 ↗
29. GB 50010-2010, Code for design of concrete structures[S]. Beijing: China Architecture & Building Press, 2010.
30. Bond behavior of fiber reinforced polymer bars under direct pullout conditions10.1061/(ASCE)1090-0268(2004)8:2(173) ↗
31. JGT 160-2017, Mechanical anchors for use in concrete[S]. Beijing: Standards Press of China, 2017.
32. GB/T 14370-2015, Anchorage, grip and coupler for prestressing tendons[S]. Beijing: Beijing: Standards Press of China, 2015.
33. JTS 151-2011, Design code for concrete structures of port and waterway engineering[S]. Beijing: China Communications Press, 2011.
34. Investigation of bond in concrete member with fibre reinforced polymer (FRP) bars10.1016/S0950-0618(98)00027-0 ↗
35. Experimental study on bond performance of GFRP bars in self-compacting steel fiber reinforced concrete10.1016/j.compstruct.2012.07.009 ↗
36. American Concrete Institute. ACI 318-11 Building Code Requirement for Structural Concrete and Commentary[S]. USA, 2011.
37. British Standards Institution. BS EN 1992-1-1: 2004 Eurocode 2: Design of Concrete Structures Part 1-1: General rules and rules for buildings[S]. London, 2004.
38. Standards Australia Committee. AS 3600-2009 Australian Standard Concrete Structure[S]. Sydney, 2009.
39. Japan Society of Civil Engineer. JSCE standard specifications for concrete structures-2012, Design[S]. Tokyo, 2012.