journal article·2025-08Open access

PBO-FRCM and CFRP strengthened reinforced concrete columns: In fire and post-fire behavior

Salem Khalaf, Farid Abed, Ahmed El Refai, Yazan Alhoubi, Sanaz Ramzi, Hamzeh Hajiloo

Abstract

This paper experimentally investigates the thermal response and post-fire structural behavior of seven short circular reinforced concrete columns. The variables include the type of strengthening system applied polypara-phenylene-benzo-bisthiazole (PBO) fiber-reinforced polymer (FRP) and fabric-reinforced cementitious matrix (FRCM), exposures (unexposed or fire-exposed), and using a cementitious-based Spray-applied Fire Resistive Materials (SFRM) insulation. Four columns were subjected to an ASTM E119 fire without any sustained load during the fire, while the other three columns were unexposed and served as controls. Two months after the fire test, fire-exposed columns were tested under axial loading and compared with unexposed ones. The steel rebar temperature in the insulated FRCM column remained below 150 °C for three hours, while this temperature was over 700 °C for the insulated CFRP-wrapped column. The post-fire axial tests indicated that the fire-exposed, insulated PBO-FRCM wrapped column retained a residual axial capacity of 92 %, significantly higher than the 21–66 % range observed in the other three columns. Considering reduced material properties, ACI code-based predictions for axial capacity showed reasonable accuracy with predicted-to-experimental ratios ranging from 0.86 to 1.16.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Fire effects on concrete materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (63)

Show source-provided references
1. An overview of research and applications of FRP in New Zealand reinforced concrete structures10.1080/10168664.2019.1699491 ↗
2. Bond between TRM versus FRP composites and concrete at high temperatures10.1016/j.compositesb.2017.05.064 ↗
3. Fire performance of CFRP-strengthened piloti-type columns with fire-resistant materials during standard fire exposure10.1038/s41598-024-74306-7 ↗
4. Mechanical behaviour of pultruded glass fibre reinforced polymer composites at elevated temperature: Experiments and model assessment10.1016/j.compstruct.2012.10.051 ↗
5. GFRP-Reinforced Concrete Slabs: Fire Resistance and Design Efficiency10.1061/(ASCE)CC.1943-5614.0000937 ↗
6. Fire Behavior of GFRP-Reinforced Concrete Structural Members: A State-of-the-Art Review10.1061/JCCOF2.CCENG-4268 ↗
7. Strengthening of concrete structures with textile reinforced mortars: State-of-the-art review10.1061/(ASCE)CC.1943-5614.0000882 ↗
8. Experimental investigation of the TRM-to-masonry bond after exposure to elevated temperatures: Cementitious and alkali-activated matrices of various densities10.3390/ma15010140 ↗
9. Flexural analysis of reinforced concrete beams strengthened with a cement based high strength composite material10.1016/j.compstruct.2011.07.008 ↗
10. Effectiveness of fabric-reinforced cementitious matrix in strengthening reinforced concrete beams10.1061/(ASCE)CC.1943-5614.0000741 ↗
11. Flexural strengthening of RC beams with cement-based composites10.1061/(ASCE)CC.1943-5614.0000218 ↗
12. Textile-reinforced mortar (TRM) versus fiber-reinforced polymers (FRP) in shear strengthening of concrete beams10.1016/j.compositesb.2015.03.055 ↗
13. Shear strengthening of full-scale RC T-beams using textile-reinforced mortar and textile-based anchors10.1016/j.compositesb.2016.03.076 ↗
14. A machine learning approach for predicting a full load-deflection behaviour of strengthened beams using fabric-reinforced cementitious matrix (FRCM)10.1016/j.engstruct.2025.120580 ↗
15. Flexural strengthening of two-way RC slabs with textile-reinforced mortar: experimental investigation and design equations10.1061/(ASCE)CC.1943-5614.0000713 ↗
16. Performance of RC slab-type elements strengthened with fabric-reinforced cementitious-matrix composites10.1061/(ASCE)CC.1943-5614.0000415 ↗
17. Enhancing flexural and shear capacities of RC T-beams with FRCM incorporating a full FRCM-concrete bond
18. Structural behaviour of fabric reinforced cementitious matrix (FRCM) strengthened concrete columns under eccentric loading10.1016/j.compositesb.2015.01.042 ↗
19. Textile-reinforced mortar versus FRP jacketing in seismic retrofitting of RC columns with continuous or lap-spliced deformed bars10.1061/(ASCE)CC.1943-5614.0000028 ↗
20. Concrete columns confined with fibre reinforced cementitious mortars: Experimentation and modelling10.1016/j.conbuildmat.2013.11.048 ↗
21. Fire behaviour of FRP-strengthened reinforced concrete structural elements: A state-of-the-art review10.1016/j.compositesb.2015.05.045 ↗
22. Bond Strength of GFRP Reinforcing Bars at High Temperatures with Implications for Performance in Fire10.1061/(ASCE)CC.1943-5614.0000897 ↗
23. Post-fire performance of hybrid GFRP-steel reinforced concrete columns10.1016/j.conbuildmat.2024.138655 ↗
24. The experimental behavior of FRP-strengthened RC beams subjected to design fire exposure10.1016/j.engstruct.2011.03.010 ↗
25. Bond Performance of GFRP Reinforcing Bars under Uniform or Gradient Temperature Distributions10.1061/(ASCE)CC.1943-5614.0001169 ↗
26. Performance of CFRP strengthened concrete members under elevated temperatures
27. Effect of elevated service temperature on bond between FRP EBR systems and concrete10.1016/j.compositesb.2008.06.004 ↗
28. The influence of temperature on the debonding of externally bonded CFRP
29. Fire behaviour of reinforced concrete columns confined with fibre-reinforced polymers
30. Performance in fire of FRP-strengthened and insulated reinforced concrete columns10.1016/j.firesaf.2012.08.006 ↗
31. Performance of insulated FRP-strengthened concrete flexural members under fire conditions10.1007/s11709-021-0714-z ↗
32. Investigation of insulated FRP-wrapped reinforced concrete columns in fire10.1016/j.firesaf.2006.10.007 ↗
33. Behaviour of fibre reinforced polymer-strengthened T-beams and slabs in fire10.1680/stbu.11.00014 ↗
34. High temperature properties of fiber reinforced polymers and fire insulation for fire resistance modeling of strengthened concrete structures10.1016/j.compositesb.2019.107104 ↗
35. Tensile properties of carbon fabric-reinforced cementitious matrix (FRCM) at high temperatures10.1016/j.istruc.2023.06.025 ↗
36. and Materials, B., Effect of elevated temperature environments on the residual axial capacity of RC columns strengthened with different techniques.
37. Fire insulation schemes for FRP-strengthened concrete slabs10.1016/j.compositesa.2005.05.028 ↗
38. Experimental evaluation of the fire behaviour of insulated fibre-reinforced-polymer-strengthened reinforced concrete columns10.1016/j.firesaf.2006.05.004 ↗
39. CAN/ULC-S101-M89, U., Standard Methods of Fire Endurance Tests of Building Construction and Materials. 1989.
40. Textile-reinforced mortar versus fiber-reinforced polymer confinement in reinforced concrete columns.
41. A comparison between the use of FRP, FRCM and HPM for concrete confinement10.1016/j.compositesb.2018.12.111 ↗
42. Textile Reinforced Mortars (TRM) versus Fiber ReinforcedPolymers (FRP) as StrengtheningMaterials of Concrete Structures
43. Simplified analytical models for compressed concrete columns confined by FRP and FRCM system10.1617/s11527-017-1110-y ↗
44. The effect of high temperature on the performance of CFRP and FRCM confined concrete elements10.1016/j.compositesb.2013.05.016 ↗
45. Concrete confinement with TRM versus FRP jackets at elevated temperatures10.1617/s11527-020-01492-x ↗
46. Experimental investigation of concrete cylinders confined with PBO FRCM exposed to elevated temperatures10.3390/fire6080322 ↗
47. ASTM, Standard Test Methods for Fire Tests of Building Construction and Materials. ASTM E119, 2024.
48. ACI (American Concrete Institute), Building Code Requirements for Structural Concrete (ACI 318-02) and Commentary (ACI 318R-02). 1999.
49. ASTM, Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens. ASTM C39/C39M-24, 2024.
50. ASTM, Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement. ASTM A615/A615M-24, 2022.
51. ASTM, Standard Test Method for Tensile Properties of Polymer Matrix Composite Materials. ASTM D3039/D3039M-17, 2017.
52. Sikacrete®-213 F wet-sprayed fire protection mortar. 2020.
53. Compressive strength of cfrp confined concrete under exposure to high temperature
54. 1-2: Design of concrete structures-Part 1-2: General rules-Structural fire design
55. FRP confined concrete columns: Behaviour under extreme conditions10.1016/j.cemconcomp.2006.07.008 ↗
56. Structural performances of thermally conditioned PBO FRCM confined concrete cylinders10.1016/j.compstruct.2017.06.026 ↗
57. Strengthening pre-damaged RC square columns with fabric-reinforced cementitious matrix (FRCM): Experimental investigation10.1016/j.compstruct.2022.115784 ↗
58. Axial load behavior of LargeScale spirally reinforced HighStrength concrete columns
59. Guide to Design and Construction of Externally Bonded Fabric-Reinforced Cementitious Matrix and Steel-Reinforced Grout Systems for Repair and Strengthening of Concrete Structures
60. Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures
61. Simplified approach for evaluating residual strength of fire-exposed reinforced concrete columns10.1617/s11527-013-0036-2 ↗
62. Residual mechanical properties of PBO FRCM composites after elevated temperature exposure: Experimental and comparative analysis10.1061/JMCEE7.MTENG-15917 ↗
63. ACI (American Concrete Institute), ACI CODE-318-19 (22): Building Code Requirements for Structural Concrete. 2022.