Acoustic emission for monitoring a reinforced concrete beam subject to four-point-bending
Source abstract
Abstract
Acoustic emission (AE) analysis is applied to monitor the deterioration progress of a reinforced concrete beam under loading in a laboratory test. Accuracy of AE locations is discussed. Picking of signal onsets was done using an automatic routine that showed reliable results compared to manually set picks. Elastic wave propagation was numerically modeled to quantify perturbations by a grouted or ungrouted tendon. In the experiments, temporal and spatial occurrence of AE correlates with macroscopically observed deterioration progress. The location capability decreases when cracking of the concrete occurs. Location results then may not represent all ongoing deterioration processes.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Geophysical Methods and Applications · Seismic Waves and Analysis · Seismology and Earthquake Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. Köppel SA, Vogel T. Localization and identification of cracking mechanisms in reinforced concrete using acoustic emission analysis. In: Proceedings of the fourth international conference on bridge management. Surrey 2000;89–95.
2. Damage assessment of reinforced concrete beams qualified by acoustic emission
3. Holford KM, Pullin R, Lark RJ. Acoustic emission monitoring of concrete hinge joint models. In: Proceedings of the 26th European conference on acoustic emission testing. Berlin; 2004;237–245.10.4028/www.scientific.net/KEM.245-246.323 ↗
4. Colombo S, Forde MC, Main IG, Hill B, Halliday J. Application of AET to concrete bridges: practical considerations and a case study. In: Proceedings of the structural faults and repair. London; 2003.
5. Shiotani T, Nakanishi Y, Luo X, Haya H, Inaba T. Evaluation of structural integrity in railway structures using train-induced acoustic emission. In: Proceedings of the structural faults and repair. London; 2003.
6. Continuous acoustic monitoring of grouted post-tensioned concrete bridges10.1016/S0963-8695(00)00034-7 ↗
7. Fricker S, Vogel T. Site installation and testing of permanent acoustic monitoring. In: Proceedings of the European network on structural assessment, monitoring and control summer academy. Zell am See, Austria; 2005.
8. The mechanics of locating earthquakes10.1785/BSSA0660010173 ↗
9. Confidence regions and error determinations for seismic event location10.1029/RG003i001p00157 ↗
10. Press · 1992
11. Strategies for reliable automatic onset time picking of acoustic emissions and of ultrasound signals in concrete10.1016/j.ultras.2004.12.005 ↗
12. Numerical modeling of elastic wave propagation and scattering with EFIT – elastodynamic finite integration technique10.1016/0165-2125(94)00040-C ↗
13. Three-dimensional time domain modeling of ultrasonic wave propagation in concrete in explicit consideration of aggregates and porosity10.1142/S0218396X01000978 ↗
14. Numerical modeling of acoustic emission sources and wave propagation in concrete