An experimental study of the jacketed reinforced-concrete beams under bending
Source abstract
Abstract
Abstract Existing reinforced-concrete (RC) structures may require strengthening to limit earthquake damage. Jacketing by steel plates, by fibre-reinforced-concrete, and by ordinary RC are common ways of strengthening structural members. In this study, flexural behaviours of RC beams and those of the same beams having been jacketed by RC after the former were loaded to full plastic yield under bending are experimentally determined, both being under-reinforced. It is noted that the mechanical behaviours of the jacketed RC beams are similar to and slightly better than those ordinary RC beams of the same dimensions, despite the fact that the core parts of the jacketed RC beams were in a yielded state.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Structural Response to Dynamic Loads
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (12)
Show source-provided references
1. Zahran M, Kimura T, Ueda T, Kakuta Y. A study on the fatigue fracture of shear reinforcing steel plates in steel concrete sandwich beams. In: Proceedings of the Hokkaido Chapter of JSCE, vol. 52; 1996. p. 638–43
2. Dolan CW, Leu B, Hundley A. Creep-rupture of fiber-reinforced plastics in a concrete environment. In: Proceedings of the Third International Symposium on Non-Metallic (FRP) Reinforcement for Concrete Structures (FRPRCS-3), vol. 2. Sapporo, Japan: Japan Concrete Institute; 1997. p. 187–94
3. Almusallam TH, Al-Salloum Y, Alsayed S, Amjad M. Behaviour of concrete beams doubly reinforced by FRP bars. In: Proceedings of the Third International Symposium on Non-Metallic (FRP) Reinforcement for Concrete Structures (FRPRCS-3), vol. 2. Sapporo, Japan: Japan Concrete Institute; 1997. p. 471–8
4. Karbhari VM, Eckel DA. Effects of short-term environmental exposure on axial strengthening capacity of composite jacketed concrete, J Compos Technol Res ASTM 1995;17(2):99–10610.1520/CTR10472J ↗
5. Composite jacketed concrete under uniaxial compression verification of simple design equations10.1061/(ASCE)0899-1561(1997)9:4(185) ↗
6. Repaired reinforced concrete beams
7. Experimental behaviour of jacketed reinforced concrete beams10.1061/(ASCE)0733-9445(2000)126:6(692) ↗
8. Cen, Eurocode 8. Design of Structure for earthquake resistance – Part 3: strengthening and repair of buildings. Draft No. 1, Brussels 8; 2001
9. Cen, Eurocode 8. Design provisions for earthquake resistance structures – Part 1–4; General rules – strengthening and repair of buildings. ENV 1998-1.4, Brussels; 1996
10. British Standards Institute. British standard for structural use of concrete. Parts 1 and 2, BS 8110. London; 1985
11. Turkish Standards Institute. Requirements for design and construction of reinforced concrete structures. Ankara; 2000
12. Flexural behaviour of composite reinforced concrete elements10.1061/(ASCE)0899-1561(2001)13:4(255) ↗