Determining the air-void distribution in fresh concrete with the Sequential Air Method
Source abstract
Abstract
Abstract A new approach is presented to determine the air void size and spacing in fresh air entrained concrete by measuring the change in response of the concrete to a series of sequential pressures. This information is used to calculate a parameter called the Sequential Air Method (SAM) Number. Comparisons are made to hardened air void analysis (ASTM C457 ) from laboratory and field tests for 303 mixtures as well as rapid freeze-thaw testing (ASTM C666 ) for 68 mixtures to the SAM Number with over 85% agreement. Furthermore, the SAM Number showed a higher correlation to rapid freeze-thaw testing than current recommendations for the Spacing Factor. The variability of the SAM Number is compared to other direct and indirect measurements of air void size and spacing. Finally, several applications of the method are discussed along with guidance on how to specify the method.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete and Cement Materials Research · Concrete Properties and Behavior · Innovative concrete reinforcement materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Kosmatka · 2016
2. Pigeon · 1995
3. Mechanisms of frost damage
4. Void spacing as a basis for producing air-entrained concrete
5. D. Whiting, D. Stark, Control of air content in concrete. NCHRP report, 1983 (258).
6. Kleiger · 1952
7. Kleiger · 1956
8. 211, A.C. Standard Practice for Selecting Proportions for Normal, Heavyweight and Mass Concrete, 1991. American Concrete Institute.
9. T.C. Powers, T. Willis. The air requirement of frost resistant concrete. in: Highway Research Board Proceedings, 1950.
10. 201.2R, A.C. Guide to Durable Concrete, 2016, American Concrete Institute.
11. ASTM-C457, Standard Practice for Microscopical Determination of Air-Void Content and Parameters of the Air-Void System in Hardened Concrete, 2017, ASTM International: West Conshohocken, PA.
12. F. Gay, A factor which may affect differences in the determined air content of plastic and hardened air-entrained concrete, in: Proceedings of the Fourth International Conference on Cement Microscopy, Las Vegas, Int. Cem. Microscopy Assoc. 1982.
13. F.T. Gay, The effect of mix temperature on air content and spacing factors of hardened concrete mixes with standardized additions of air-entraining agent, in: Proceedings, Seventh International Conference on Cement Microscopy, Fort Worth, International Cement Microscopy Assoc., Duncanville, TX. 1985.
14. The influence of water-reducers on the production and stability of the air void system in concrete10.1016/0008-8846(89)90014-8 ↗
15. A closer look at entrained air in concrete
16. Freeman · 2012
17. Durable Concrete with Modern Air-Entraining Admixtures
18. Influence of pumping on characteristics of air-void system of high-performance concrete
19. D. Janssen, K. Macdonald, A. Gardiner. Effects of pumping parameters on the stability of entrained air voids, in: CONSEC'01: Third International Conference on Concrete Under Severe Conditions, 2001.
20. W.D. Elkey, D.J. Janssen, K.C. Hover. Effects of admixtures on air-void stability of concrete subjected to pressurization. in: Concrete Under Severe Conditions 2, 1998.
21. D.J. Janssen, R.M. Dyer, W.E. Elkey, Effect of pumping on entrained air voids: role of pressure, in: CONSEC 95 Concrete Under Severe Conditions, 1995.
22. B.J. Jensen, Method of determining the air bubble size distribution in fresh concrete, an analytical assembly and a sample taking device for use herewith, 1990, Google Patents.
23. D.D. Magura, Air void analyzer evaluation, 1996.
24. D.H. Desai, P.J. Tikalsky, B.E. Scheetz, Hardened air in concrete roadway pavements in structure, 2007.
25. ASTM-C150/C150M, ASTM C150/C150M: Standard Specification for Portland Cement. 2011, ASTM International: West Conshohocken, PA. p. 9.
26. ASTM-C33, Standard Specification for Concrete Aggregates, 2016, ASTM International: West Conshohocken, PA.
27. ASTM-C494, Standard Specification for Chemical Admixtures for Concrete, 2005, ASTM International: West Conshohocken, PA.
28. ASTM-C260-10a, Standard Specification for Air-Entraining Admixtures for Concrete, 2010, ASTM International: West Conshohocken, PA.
29. ASTM-C1017-13ε1, Standard Specification for Chemical Admixtures for Use in Producing Flowing Concrete, 2005, ASTM International: West Conshohocken, PA.
30. ASTM-C618, Standard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete, 2008, ASTM International: West Conshohocken, PA. p. 3.
31. Welchel · 2014
32. Super air meter for assessing air-void system of fresh concrete10.1520/ACEM20150009 ↗
33. ASTM-C666, Standard Test Method for Resistance of Concrete to Rapid Freezing and Thawing, 2015, ASTM International: West Conshohocken, PA.
34. ASTM-C231, Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method, 2017, ASTM International: West Conshohocken, PA.
35. Analytical investigation of the influence of air bubble size on the determination of the air content of freshly mixed concrete10.1520/CCA10028J ↗
36. W. Klein, S. Walker, A method for direct measurement of entrained air in concrete. in: Journal Proceedings, 1946.
37. LeFlore, J. Super Air Meter Test Video, 2016; Available from: https://www.youtube.com/watch?v=xAcHqMz_m3I.
38. M.T. Ley, B. Tabb, A test method to measure the freeze thaw durability of fresh concrete using overpressure, in: T&DI Congress 2014: Planes, Trains, and Automobiles, 2014.10.1061/9780784413586.008 ↗
39. ASTM-C156, Standard Test Method for Water Loss [from a Mortar Specimen] Through Liquid Membrane-Forming Curing Compounds for Concrete, 2011, ASTM International: West Conshohocken, PA.
40. M.T. Ley, The effects of fly ash on the ability to entrain and stabilize air in concrete, 2007, ProQuest.
41. Automated air void analysis of hardened concrete—a Round Robin study10.1016/j.cemconres.2006.03.005 ↗
42. K. Peterson, L. Sutter, M. Radlinski, The practical application of a flatbed scanner for air-void characterization of hardened concrete, in: Recent Advancement in Concrete Freezing-Thawing (FT) Durability, ASTM International, 2010.10.1520/JAI102446 ↗