Bond behaviours of deformed steel rebars in engineered cementitious composites (ECC) and concrete
Source abstract
Abstract
This paper presents the bond behaviors of deformed steel rebars in engineered cementitious composite (ECC) and concrete under direct pullout condition. A total of 12 specimens were casted and tested, it was found that the deformed steel rebar has a much higher bond strength in ECC than in concrete due to the superior tensile ductility of ECC material. A new finite element analysis (FEA) model, which considered the influences of steel ribs, was proposed and verified with the experimental results. Based on the proposed FEA model, the failure mechanisms and bond deterioration processes for both ECC and concrete specimens were analyzed and compared. It was found that the plastic area ratio for ECC specimen was as high as 32.2%, which is 3.3 times higher than that for concrete specimen. Also, the ultimate damage zone for ECC specimen is 36% lower than that for concrete specimen. It was concluded that ECC specimen has more compatible deformability with steel rebar as more ECC elements could participate in the transfer of tensile load.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Load-Bearing Analysis · Concrete Corrosion and Durability
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Tensile strain-hardening behavior of polyvinyl alcohol engineered cementitious composite (PVA-ECC)
2. Tensile and fiber dispersion performance of ECC (engineered cementitious composites) produced with ground granulated blast furnace slag10.1016/j.cemconres.2007.04.006 ↗
3. Mechanical behavior of fiber-reinforced engineered cementitious composites in uniaxial compression
4. Flexural behavior of engineered cementitious composite (ECC) slabs with polyvinyl alcohol fibers10.1016/j.conbuildmat.2014.10.036 ↗
5. Mechanical behaviors of steel reinforced ECC or ECC/concrete composite beams under reversed cyclic loading10.1061/(ASCE)MT.1943-5533.0000935 ↗
6. Seismic behavior of steel reinforced ECC columns under constant axial loading and reversed cyclic lateral loading10.1617/s11527-016-0947-9 ↗
7. Seismic behavior of hybrid fiber reinforced cementitious composite beam–column joints10.1016/j.matdes.2015.07.164 ↗
8. High-strength steel reinforced squat UHPFRC shear walls: cyclic behavior and design implications10.1016/j.engstruct.2017.02.068 ↗
9. Bond-slip in reinforced concrete elements10.1061/(ASCE)0733-9445(2005)131:11(1690) ↗
10. An experimental study on the bond strength between reinforcement bars and concrete as a function of concrete cover, strength and corrosion level10.1016/j.cemconres.2012.01.003 ↗
11. Experimental and analytical investigation on bond-slip behaviour of deformed bars embedded in engineered cementitious composites10.1016/j.conbuildmat.2016.10.036 ↗
12. Bond behavior of steel bar embedded in Engineered Cementitious Composites under pullout load10.1016/j.conbuildmat.2018.02.165 ↗
13. Bond behavior between steel bar and engineered cementitious composite (ECC) considering lateral FRP confinement: Test and modeling
14. Bond behaviour of bars embedded in ecological high-ductility cementitious composites10.1680/jmacr.18.00160 ↗
15. Bond-stress and bar-strain profiles in RC tension members modelled via finite element10.1016/j.engstruct.2019.05.069 ↗
16. Effect of shear span-to-depth ratio on shear strength components of RC beams10.1016/j.engstruct.2018.05.017 ↗
17. Development of multiscale fiber-reinforced engineered cementitious composites with PVA fiber and CaCO3 whisker10.1061/(ASCE)MT.1943-5533.0002305 ↗
18. Japan Society of Civil Engineers (2004) Recommendations for design and construction of ultra high-strength fiber reinforced concrete structures (draft), Concrete Library 113.
19. ASTM A370–14, “Standard Test Methods and Definitions for Mechanical Testing of Steel Products”, ASTM International, West 2014 Conshohocken, PA 50 pp.
20. Local bond-slip response of GFRP rebar in ultra-high-performance fiber-reinforced concrete10.1016/j.compstruct.2014.09.055 ↗
21. The effect of recycled concrete aggregate properties on the bond strength between RCA concrete and steel reinforcement10.1016/j.cemconres.2011.06.004 ↗
22. Investigation of compressive bond behavior of steel rebar embedded in concrete with partial recycled aggregate replacement10.1016/j.istruc.2016.06.010 ↗
23. Finite element modelling of reinforcement with bond10.1016/j.compstruc.2006.04.010 ↗
24. New finite element to model bond–slip with steel strain effect for the analysis of reinforced concrete structures10.1016/j.engstruct.2014.12.036 ↗
25. One-dimensional analysis of tension stiffening in reinforced concrete with discrete cracks10.1016/j.engstruct.2007.03.013 ↗
26. Performance of concrete-filled thin-walled steel tubes under pure torsion10.1016/j.tws.2007.01.008 ↗
27. CEN (European Committee for Standardization). Design of concrete structures—Part 1-1: General rules and rules for buildings. Eurocode 2, 2004.
28. Nonlinear analysis of circular concrete-filled steel tube columns under eccentric loading
29. Adhesive bonding of fire-resistive engineered cementitious composites (ECC) to steel10.1016/j.conbuildmat.2014.04.059 ↗
30. Maekawa · 2014