Experimental evaluation of cement mortars with phase change material incorporated via lightweight expanded clay aggregate
Source abstract
Abstract
Abstract Objective An experimental evaluation on cement mortars with phase change material (PCM) incorporated via lightweight aggregate (LWA) is reported. Materials and methods Three groups of LWA mortars were produced: one with pre-soaked LWA and the others with PCM-filled LWA combining two different impregnation processes and PCM dosages of 50, 75 and 100 kg/m 3 corresponding to the LWA contents of 242, 354 and 481 kg/m 3 , respectively. Mechanical and thermophysical properties were evaluated. Results The results showed that high thermal inertia and low mass are compatible in PCM-filled LWA mortars and that the thermal response increases with the PCM to a certain limit and then decrease.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Phase Change Materials Research · Adsorption and Cooling Systems · Solar Thermal and Photovoltaic Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. IEA, 2007. Energy balances for world, International Energy Agency, Paris; 2009.
2. European Commission, Directorate General for Energy and Transport. European Energy and Transport, Trends to 2030 – Update 2007; 2008.
3. A simple methodology to predict heating load at an early design stage of dwellings10.1016/j.enbuild.2012.06.033 ↗
4. Real climate experimental study of two double window systems with preheating of ventilation air10.1016/j.enbuild.2010.01.003 ↗
5. Free-cooling of buildings with phase change materials10.1016/j.ijrefrig.2004.03.015 ↗
6. Review on free cooling of buildings using phase change materials10.1016/j.rser.2010.07.004 ↗
7. Experimental study of an innovative element for passive cooling of buildings10.1016/j.seta.2013.08.002 ↗
8. Surface configuration relevance in the overall thermal resistance of a wall10.1016/j.enbuild.2004.12.012 ↗
9. Use of microencapsulated PCM in concrete walls for energy savings10.1016/j.enbuild.2006.03.030 ↗
10. Incorporation of phase change materials in cementitious systems via fine lightweight aggregate10.1016/j.conbuildmat.2012.04.042 ↗
11. Experimental study on hygrothermal behaviour of retrofit solutions applied to old building walls10.1016/j.conbuildmat.2012.04.138 ↗
12. A review on phase change energy storage: materials and applications10.1016/j.enconman.2003.09.015 ↗
13. Application of latent heat thermal energy storage in buildings: state-of-the-art and outlook10.1016/j.buildenv.2006.07.023 ↗
14. Applications of phase change material in highly energy-efficient houses10.1016/j.enbuild.2012.03.018 ↗
15. Transient behaviour of a latent heat thermal energy store: numerical and experimental studies10.1016/S0306-2619(02)00060-0 ↗
16. A work procedure of utilising PCMs as thermal storage systems based on air-TES systems10.1016/j.enconman.2013.10.012 ↗
17. NP EN 197-1:2012. Cement, Part 1: Composition, specifications and conformity criteria for common cements. Instituto Português da Qualidade (IPQ), Lisbon; 2012 [in Portuguese].
18. LNEC E64:1979. Cement: determination of density. Laboratório Nacional de Engenharia Civil (LNEC), Lisbon; 1979 [in Portuguese].
19. NP EN 1097-3:2002. Tests for mechanical and physical properties of aggregates, Part 3: Determination of loose bulk density and voids. IPQ, Lisbon; 2002 [in Portuguese].
20. NP EN 1097-6:2003. Tests for mechanical and physical properties of aggregates, Part 6: Determination of particle density and water absorption. IPQ, Lisbon; 2003 [in Portuguese].
21. NP EN 933-1:2000. Tests for geometrical properties of aggregates, Part 1: Determination of particle size distribution – sieving method. IPQ, Lisbon; 2000 [in Portuguese].
22. NP EN 934-2:2009. Admixtures for concrete, mortar and grout. Part 2: Concrete admixtures – definitions, requirements, conformity, marking and labelling. IPQ, Lisbon; 2009 [in Portuguese].
23. EN 1015-3:1999. Methods of test for mortar for masonry, Part 3: Determination of consistence of fresh mortar (by flow table). European Committee for Standardization; 1999.
24. EN 1015-11:1999. Methods of test for mortar for masonry, Part 11: Determination of flexural and compressive strength of hardened mortar, European Committee for Standardization; 1999.
25. EN 1015-10:1999. Methods of test for mortar for masonry, Part 10: Determination of dry bulk density of hardened mortar. European Committee for Standardization; 1999.
26. ASTM C 518:2004. Standard test method for steady-state thermal transmission properties by means of the heat flow meter apparatus. American Society for Testing and Materials; 2004.