journal article·2014-06

Effect of eccentric compression loading on the strains of FRCM confined concrete columns

Tomasz Trapko

Publisher page

Abstract

Abstract The paper describes the effect of eccentric compression on the strains of RC columns, reinforced with FRCM (Fibre Reinforced Cementitious Matrix) composites. Over the span of a dozen or so years, many research studies have been dedicated to the learning of the behaviour of FRP confined concrete elements. The comprehensive test results of axially and eccentrically compressed elements as well as numerous theoretical analyses provide an opinion on the effectiveness of FRPs (Fibre Reinforced Polymers). Under the FRP system, the bonding of a composite material with concrete is made using epoxy resin, on the other hand, under the FRCM system, a composite material is bonded with concrete using a mineral mortar. The FRCM strengthening is relatively poorly recognised, and the research studies presented aim at the widening of the knowledge acquired to date. The testing was performed on 15 slender reinforced concrete columns that were strengthened longitudinally and/or transversally with a composite mesh under the FRCM system. The elements were subjected to axial compression and on the eccentrics: h/6 and h/12. The paper presents the testing preparation and performance method. The description of the strengthening effectiveness was made basing on the values of the energy of destruction. On the grounds of the analysis of the Poisson’s ratio value, the impact of the strengthening method and of the eccentric on the state of stress of the material being tested was reviewed.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Innovative concrete reinforcement materials · Structural Response to Dynamic Loads

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (40)

Show source-provided references
1. Strengthening of existing concrete columns with unidirectional composite sheets
2. Axial testing of rectangular column models confined with composites10.1061/(ASCE)1090-0268(2000)4:3(129) ↗
3. Strength and strain capacities of concrete compression members reinforced with FRP10.1016/S0958-9465(01)00048-8 ↗
4. Comparative study of models on confinement of concrete cylinders with fiber-reinforced polymer composites10.1061/(ASCE)1090-0268(2003)7:3(219) ↗
5. Behavior and modeling of fiber reinforced polymer confined concrete10.1061/(ASCE)0733-9445(2004)130:11(1713) ↗
6. Experimental behavior of reinforced concrete column models strengthened by CFRP materials10.3846/13923730.2006.9636382 ↗
7. Behavior of square and circular columns strengthened with aramidic or carbon fibers10.1016/j.conbuildmat.2011.03.007 ↗
8. Cross sectional shape effects on the performance of post-heated reinforced concrete columns wrapped with FRP composites10.1016/j.compstruct.2010.09.012 ↗
9. Influence of concrete strength and confinement method on axial compressive behavior of FRP confined high- and ultra high-strength concrete
10. RC square sections confined by FRP: analytical prediction of peak strength10.1016/j.compositesb.2012.09.041 ↗
11. Effect of corner radius on stress–strain behavior of FRP confined prisms under axial cyclic compression10.1016/j.engstruct.2012.03.020 ↗
12. Behaviour of hollow core square reinforced concrete columns wrapped with CFRP with different fibre orientations10.1016/j.conbuildmat.2013.08.080 ↗
13. Comparative behaviour of hollow columns confined with FRP composites10.1016/j.compstruct.2010.05.020 ↗
14. The effects of cross-sectional shape and loading condition on performance of reinforced concrete members confined with carbon fiber-reinforced polymers10.1016/j.matdes.2009.12.004 ↗
15. Axial–flexural interaction in circular FRP-confined reinforced concrete columns10.1016/j.conbuildmat.2010.02.024 ↗
16. Effective strain of FRP for confined circular concrete columns10.1016/j.compstruct.2012.08.021 ↗
17. Experimental investigation on rectangular RC columns strengthened with CFRP composites under axial load and biaxial bending10.1016/j.compstruct.2013.09.015 ↗
18. Slenderness effect of circular concrete specimens confined with SFRP sheets10.1016/j.compositesb.2012.06.014 ↗
19. Behavior of long confined concrete column10.1016/j.asej.2011.09.003 ↗
20. Analytical model for prediction of load capacity of RC columns confined with CFRP under uniaxial and biaxial eccentric loading10.1617/s11527-010-9628-2 ↗
21. Numerical simulation and strength models of FRP-wrapped reinforced concrete columns under eccentric loading10.1016/j.conbuildmat.2010.12.036 ↗
22. Axial and flexural performance of square RC columns wrapped with CFRP under eccentric loading10.1061/(ASCE)CC.1943-5614.0000301 ↗
23. Theoretical model for slender FRP-confined circular RC columns10.1016/j.conbuildmat.2010.11.109 ↗
24. Effect of load eccentricity on the stress–strain relationship of FRP-confined concrete columns10.1016/j.compstruct.2012.11.023 ↗
25. Experimental investigation of the load carrying capacity of eccentrically loaded reinforced concrete elements strengthened with CFRP10.1016/j.proeng.2013.04.032 ↗
26. Ombres L. Confinement effectiveness in concrete strengthened with fiber reinforced cement based composite jackets. In: Triantafillou TC, editor. FRPRCS-8: proceedings of the 8th international symposium on fiber-reinforced polymer reinforcement for concrete structures, 2007 July 16–18. Patras, Greece. University of Patras; 2007 [on CD, Paper No. 17–11].
27. Concrete confinement with a cement based high strength composite material10.1016/j.compstruct.2013.10.037 ↗
28. Concrete columns confined with fibre reinforced cementitious mortars: experimentation and modelling10.1016/j.conbuildmat.2013.11.048 ↗
29. Stress–strain model for FRCM confined concrete elements10.1016/j.compositesb.2012.07.001 ↗
30. Fibre reinforced cementitious matrix confined concrete elements10.1016/j.matdes.2012.08.024 ↗
31. The effect of high temperature on the performance of CFRP and FRCM confined concrete elements10.1016/j.compositesb.2013.05.016 ↗
32. Behaviour of fibre reinforced cementitious matrix strengthened concrete columns under eccentric compression loading10.1016/j.matdes.2013.09.008 ↗
33. Deformability of compressed concrete elements strengthened with FRCM composite materials10.35784/bud-arch.2188 ↗
34. Experimental analysis on bond between PBO-FRCM strengthening materials and concrete
35. Bond-slip relations for PBO-FRCM materials externally bonded to concrete
36. Experimental and analytical investigation on bond between carbon-FRCM materials and masonry
37. PN-EN 1992:2008. Eurocode 2. Design of concrete structures – Part 1-1: general rules and rules for buildings.
38. Technical approval. The Road and Bridge Research Institute, Poland. No AT/2011-02-2701/1.
39. ISO 527-5:2009. International Organization for Standardization ISO. Plastic – determination of tensile properties, Part 5: test conditions for unidirectional fibre – reinforced plastic components.
40. Hoła J. Relation of initiating and critical stress to stress failure. Scientific Papers of the Institute of Building Engineering of the Wroclaw University of Technology, No. 76, Monographs No. 33, Wroclaw University of Technology Publishing House, Wroclaw 2000. 38 p. [in Polish].