journal article·2016-09

Comparison of laboratory and field environmental conditioning on FRP-concrete bond durability

Jovan Tatar, H.R. Hamilton

Publisher page

Abstract

Abstract Assessment of bonded FRP durability by means of accelerated conditioning is sometimes thought to be too harsh compared to ambient environmental conditions; consequently, this may result in underestimate of the actual durability. To assess the efficacy of utilizing accelerated conditioning protocols (ACP) for FRP-concrete bond durability testing, results from laboratory and field conditions (Sunshine Skyway Bridge in Tampa, FL) were compared. Direct tension pull-off test patches were applied to the approach span girders and notched beam three-point bending test specimens were placed on the dolphins adjacent to the bridge. These results were compared to notched beam specimens exposed to ACP. Testing indicated that characteristics of the FRP-concrete bond failure modes changed in some of the field samples within 6 months of field exposure, which may be an indication of durability problems. Moreover, ACP under elevated temperatures (60 °C) of notched three-point bending test resulted in a 36% loss of strength compared to no strength degradation after 18 months of field conditioning.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Structural Engineering and Vibration Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. ASTM Standard C150 · 2015
2. ASTM Standard C33 · 2013
3. ASTM Standard D7522 · 2015
4. AASHTO · 2010
5. ACI Committee 440 · 2008
6. ACI Committee 318 · 2014
7. ACI Committee 440 · 2013
8. ACI Committee 440 · 2015
9. Peel and shear fracture characterization of debonding in FRP plated concrete affected by moisture10.1061/(ASCE)1090-0268(2006)10:1(35) ↗
10. Effects of hygrothermal conditioning on epoxy adhesives used in FRP composites10.1016/j.conbuildmat.2015.08.056 ↗
11. Durability of concrete beams externally reinforced with CFRP composites exposed to various environments10.1061/(ASCE)CC.1943-5614.0000233 ↗
12. Small beam bond test method for CFRP composites applied to concrete10.1061/(ASCE)CC.1943-5614.0000151 ↗
13. Effect of freeze-thaw cycles on the bond durability between fiber reinforced polymer plate reinforcement and concrete10.1139/l00-031 ↗
14. Hahn · 1991
15. Development of standard bond capacity test for FRP bonded to concrete
16. Acceptance criteria for concrete and reinforced and unreinforced masonry strengthening using externally bonded FRP composite systems
17. Effect of elevated service temperature on bond between FRP EBR systems and concrete10.1016/j.compositesb.2008.06.004 ↗
18. Degradation of bond between FRP and RC beams10.1016/j.compstruct.2007.10.014 ↗
19. Stewart · 2012
20. Direct shear adhesive bond test
21. Bond durability factor for externally bonded CFRP systems in concrete structures
22. Implementation of bond durability in the design of flexural members with externally bonded FRP
23. Environmental durability of externally bonded FRP materials intended for repair of concrete structures10.1016/j.conbuildmat.2010.11.096 ↗