journal article·2018-06

Experimental investigation on properties of interface between concrete layers

Peng Qian, Qianjun Xu

Publisher page

Abstract

Abstract The integration and permeability of the interface between concrete layers of a dam considerably affect its structural functionality and safety. To understand the interface properties, several tests were conducted to examine the various characteristics of specimens with different layer interfaces. The mechanical property in terms of bond strength was assessed using the splitting tensile test, which was affected by interval time. On the other hand, the ultrasonic pulse test was used to confirm the influence of the interface on ultrasonic attenuation. The chloride and water permeability were also investigated by means of the rapid chloride permeability, alternating current resistance, and water permeability tests. The results of these tests proved that longer interval times lead to a weaker bond strength and higher permeability, which are harmful to layer structures. The change rules of mechanical and permeability properties were confirmed by the optical micrograph and hardness distribution of the overlay transition zone. Finally, the relationships among these tests were analyzed, and strong correlations demonstrated that the non-destructive ultrasonic pulse test and rapid electrical test could be employed to predict and evaluate the bond strength and permeability of a layered interface.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Geophysical Methods and Applications · Infrastructure Maintenance and Monitoring · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. 207. Roller compacted mass concrete
2. Compaction properties of roller compacted concrete10.1016/0958-9465(95)00007-0 ↗
3. Harmonic thermal fracture of multiple crack system and the stability of cracks in RCC arch dam10.1016/0013-7944(95)00230-8 ↗
4. Coupled seepage and stress fields in roller compacted concrete dam
5. Permeability of roller compacted concrete10.1061/(ASCE)0899-1561(1992)4:1(27) ↗
6. Damage assessment of FRP-encased concrete using ultrasonic pulse velocity
7. R.A. Andreatta, W.S. Hart, B.A. Williams, et al., Investigation of lift bonding for roller-compacted concrete with low normal loads at variable placement times, 2013.
8. Ultrasonic pulse velocity in nondestructive evaluation of low quality and damaged concrete and masonry construction10.1061/(ASCE)0887-3828(2007)21:5(337) ↗
9. Characterizing the effect of compressive damage on transport properties of cracked concretes10.1617/s11527-011-9771-4 ↗
10. Statistical analysis of initial defects between concrete layers of dam using X-ray computed tomography10.1016/j.conbuildmat.2016.08.149 ↗
11. The conduction of electricity through concrete10.1680/macr.1981.33.114.48 ↗
12. R.P. Spragg, The rapid assessment of transport properties of cementitious materials using electrical methods, Dissertations & Theses – Gradworks, 2013.
13. Practical evaluation of relationship between concrete resistivity, water penetration, rapid chloride penetration and compressive strength10.1016/j.conbuildmat.2010.11.069 ↗
14. Water permeability and chloride penetrability of high-strength lightweight aggregate concrete10.1016/S0008-8846(01)00738-4 ↗
15. Characterizing enhanced porosity concrete using electrical impedance to predict acoustic and hydraulic performance10.1016/j.cemconres.2006.09.001 ↗
16. ASTM C403, Standard test method for time of setting of concrete mixtures by penetration resistance, 1995.
17. Quality identifying standard for RCC interlayer properties of Longtan Dam
18. ASTM C 496, Standard test method for splitting tensile strength of cylindrical concrete specimens, ASTM International, USA, 2004.
19. Experimental and analytical investigations on the behavior of interface between concrete and polymer cement mortar under hygrothermal conditions10.1016/j.conbuildmat.2015.07.035 ↗
20. ASTM C1202, Standard test method for electrical indication of concrete’s ability to resist chloride ion penetration, 1997.
21. History of the rapid chloride permeability test
22. Mechanical and permeability properties of the interface between normal concrete substrate and ultra high performance fiber concrete overlay10.1016/j.conbuildmat.2012.06.013 ↗
23. Rapid chloride permeability test on blended cement and other concretes: correlations between charge, initial current and conductivity10.1016/S0950-0618(98)00033-6 ↗
24. Study of the Joule effect on rapid chloride permeability values and evaluation of related electrical properties of concretes10.1016/j.cemconres.2003.11.012 ↗
25. An alternating test method for concrete permeability 110.1016/S0008-8846(97)00212-3 ↗
26. Water seepage flow in concrete10.1016/j.conbuildmat.2012.04.043 ↗
27. Microhardness testing of cementitious materials10.1016/S1065-7355(96)90051-6 ↗
28. Link between microstructure and tritiated water diffusivity in mortars: impact of aggregates10.1016/j.cemconres.2016.01.003 ↗
29. Effect of grout proportions on tensile strength of two-stage concrete measured by split and double-punch tests10.1680/stco.2004.5.4.173 ↗
30. Study of underwater concrete using two-stage (pre-placed aggregate) concrete in Libya10.1680/stco.2010.11.3.161 ↗
31. Evaluation of energy dissipation in flexure for two stage concrete
32. The relationships between the velocities, attenuation, and petrophysical properties of reservoir sediment rocks10.1111/j.1365-2478.1994.tb00204.x ↗
33. Microstructure model of the interfacial zone between fresh and old concrete10.1007/BF02838421 ↗
34. Microstructural and statistical evaluation of interfacial zone percolation in concrete