journal article·2015-01

Influence of shrinkage on compressive behavior of concrete-filled FRP tubes: An experimental study on interface gap effect

Thomas Vincent, Togay Ozbakkaloglu

Publisher page

Abstract

Abstract Fiber reinforced polymer (FRP)-confined concrete has received significant research attention over the last two decades, with recent experimental studies identifying significant benefits of FRP-confined high-strength concrete (HSC). However, studies examining the influence of concrete shrinkage on the behavior of FRP-confined concrete remain limited, with no studies examining this effect for HSC specimens. Concrete shrinkage may pose a concern for concrete-filled FRP tubes (CFFTs), as in these members the curing of concrete takes place inside the FRP tube. This paper presents an experimental investigation on the influence of FRP-to-concrete interface gap, caused by concrete shrinkage, on axial compressive behavior of FRP-confined normal- and high-strength concrete (NSC and HSC). A total of 30 aramid FRP (AFRP)-confined concrete specimens with circular cross-sections were manufactured. Six of the specimens were instrumented to monitor long term shrinkage strain development of the FRP-confined NSC and HSC, with three specimens allocated to each mix. The remaining 24 specimens were tested under axial compression, where nine of these specimens were manufactured with NSC and the remaining 15 with HSC. The influence of concrete shrinkage was examined by applying a gap of up to 0.12 mm thickness at the FRP-to-concrete interface, simulating 1600 microstrain of shrinkage in the radial direction. The results of this experimental study indicate that the influence of interface gap on axial strain enhancement is significant, with an increase observed as the gap increased. Conversely, the influence of interface gap on axial strength enhancement is found to be small with a slight reduction observed with increased gap. The results also indicate that an increase in interface gap causes an increase in strength loss during the transition region of the stress–strain curve as a result of the delayed activation of the FRP shell. Finally, it was observed that an increase in FRP-to-concrete interface gap leads to an increased difference between axial deformation of the concrete core and FRP shell, indicating the presence of interface slip.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Concrete Corrosion and Durability · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (53)

Show source-provided references
1. Confinement model for axially loaded concrete confined by circular fiber-reinforced polymer tubes
2. Concrete confined by FRP material: a plasticity approach10.1016/S0141-0296(02)00011-1 ↗
3. Analysis-oriented stress-strain models for FRP-confined concrete10.1016/j.engstruct.2007.01.010 ↗
4. FRP retrofit of low and medium strength circular and rectangular reinforced concrete columns10.1061/(ASCE)0899-1561(2008)20:2(169) ↗
5. Effect of cross-sectional aspect ratio on the strength of CFRP-confined rectangular concrete columns10.1016/j.engstruct.2009.08.012 ↗
6. Confinement model for FRP-confined high-strength concrete
7. Axial compressive behavior of circular high-strength concrete-filled FRP tubes10.1061/(ASCE)CC.1943-5614.0000321 ↗
8. Influence of concrete strength and confinement method on axial compressive behavior of FRP-confined high- and ultra high-strength concrete10.1016/j.compositesb.2013.02.017 ↗
9. Influence of fiber orientation and specimen end condition on axial compressive behavior of FRP-confined concrete10.1016/j.conbuildmat.2013.05.085 ↗
10. Behavior of FRP-confined normal- and high-strength concrete under cyclic axial compression10.1061/(ASCE)CC.1943-5614.0000273 ↗
11. FRP-confined concrete in circular sections: review and assessment of the stress–strain models10.1016/j.engstruct.2012.06.010 ↗
12. Axial compressive behavior of FRP-confined concrete: experimental test database and a new design-oriented model10.1016/j.compositesb.2013.07.025 ↗
13. Substandard reinforced concrete members subjected to compression: FRP confining effects10.1617/s11527-008-9351-4 ↗
14. Compressive behavior of concrete externally confined by composite jackets. Part A: experimental study10.1016/j.conbuildmat.2004.05.012 ↗
15. Effect of corner radius on the performance of CFRP-confined square concrete columns: test10.1016/j.engstruct.2007.04.016 ↗
16. Normal- and high-strength concrete circular elements wrapped with FRP composites10.1061/(ASCE)1090-0268(2009)13:2(113) ↗
17. Experimental study of normal- and high-strength concrete confined with fiber-reinforced polymers10.1061/(ASCE)CC.1943-5614.0000116 ↗
18. Behavior and modeling of confined high-strength concrete10.1061/(ASCE)CC.1943-5614.0000070 ↗
19. Behavior of concrete columns confined by fiber composites10.1061/(ASCE)0733-9445(1997)123:5(583) ↗
20. Behavior of axially loaded concrete-filled circular fiber-reinforced polymer tubes
21. Experimental and analytical modeling of concrete-filled fiber-reinforced polymer tubes subjected to combined bending and axial loads
22. Manufacture and testing of a novel FRP tube confinement system10.1016/j.engstruct.2008.01.014 ↗
23. Concrete-filled square and rectangular FRP tubes under axial compression10.1061/(ASCE)1090-0268(2008)12:4(469) ↗
24. Axial load capacity of concrete-filled FRP tube columns: experimental versus predictions10.1061/(ASCE)CC.1943-5614.0000066 ↗
25. Experimental investigation on the structural behavior of concrete filled FRP tubes with/without steel re-bar10.1007/s12205-011-1040-0 ↗
26. Axial compressive behavior of square and rectangular high-strength concrete-filled FRP tubes10.1061/(ASCE)CC.1943-5614.0000321 ↗
27. Compressive behavior of concrete-filled FRP tube columns: assessment of critical column parameters10.1016/j.engstruct.2013.01.017 ↗
28. Concrete-filled FRP tubes: manufacture and testing of new forms designed for improved performance10.1061/(ASCE)CC.1943-5614.0000334 ↗
29. Behavior of square and rectangular ultra high-strength concrete-filled FRP tubes under axial compression10.1016/j.compositesb.2013.05.007 ↗
30. Development of advanced composite carbon shell systems for concrete columns in seismic zones
31. Seismic performance of aramid fiber square tubed concrete columns with metallic and/or non-metallic reinforcement10.1177/0731684403035432 ↗
32. Seismic performance of concrete-filled FRP tube columns for bridge substructures10.1061/(ASCE)1084-0702(2006)11:3(359) ↗
33. Seismic behavior of high-strength concrete columns confined by fiber reinforced polymer tubes10.1061/(ASCE)1090-0268(2006)10:6(538) ↗
34. Seismic performance of square high-strength concrete columns in stay-in-place formwork10.1061/(ASCE)0733-9445(2007)133:1(44) ↗
35. Saatcioglu · 2008 · vol. 257
36. Seismic behavior of high-strength concrete-filled FRP tube columns10.1061/(ASCE)CC.1943-5614.0000388 ↗
37. Influence of key parameters on drying shrinkage of cementitious materials10.1016/S0008-8846(99)00156-8 ↗
38. Shrinkage of high-strength concrete and high-flowability concrete10.1080/1023697X.2010.10668201 ↗
39. Composite action in concrete filled tubes10.1061/(ASCE)0733-9445(1999)125:5(477) ↗
40. An experimental study on creep of concrete filled steel pipes10.1016/S0143-974X(00)00021-3 ↗
41. Xue J, Chen B, Briseghella B. Experimental research on debonding in concrete-filled steel tubes columns subjected to eccentric loading. IABSE Symposium Report 2010; 97(36): 40–7.10.2749/222137810796012234 ↗
42. Research on mechanical properties of separation concrete-filled steel tubes subjected to eccentric compression on non-separation side
43. Creep of high strength concrete filled steel tube columns10.1016/j.tws.2011.12.012 ↗
44. Numerical analysis of the axially loaded concrete filled steel tube columns with debonding separation at the steel-concrete interface10.12989/scs.2012.13.3.277 ↗
45. State of the art on the time-dependent behaviour of composite steel-concrete structures10.1016/j.jcsr.2012.08.005 ↗
46. Time-dependent behavior of fiber-reinforced polymer-confined concrete columns under axial loads
47. Testing and modeling of a novel FRP-encased steel-concrete composite column10.1016/j.compstruct.2010.11.017 ↗
48. ASTM. Standard test method for tensile properties of polymer matrix composites materials. D3039-M-08 2008. West Conshohocken, PA.
49. Standards_Australia. Determination of tensile properties of plastics materials. Part 3: Test conditions for films and sheets. AS 1145.3 – 2001 2001. Sydney, NSW, Australia.
50. A numerical approach to the complete stress–strain curves for concrete10.1016/0008-8846(73)90096-3 ↗
51. The axial behavior of concrete confined with fiber reinforced composite jackets10.1061/(ASCE)1090-0268(2001)5:4(237) ↗
52. Compressive behavior of carbon fiber composite jacketed concrete with circular and non-circular cross-sections10.1080/13632460309350455 ↗
53. Design-oriented stress-strain model for FRP-confined concrete10.1016/S0950-0618(03)00045-X ↗