journal article·2013-07

Performance evaluation of the post-installed anchor for sign structure in South Korea

Jin-Sup Kim, Woo-Young Jung, Min-Ho Kwon, Bu-Seog Ju

Publisher page

Abstract

Abstract In this study, numerous experimental tests for post-installed anchor systems used for sign structures in South Korea, drilled in hardened concrete were conducted in order to estimate pull-out and shear strength of the anchor based on three mechanical properties – torque ratio, embedment depth and diameter. In the pull-out tests, the pull-out strength of the anchor system depends significantly on all the three aforementioned parameters while in the shear tests, it was informed that the shear strength is not affected by torque ratio. It was also found that concrete cone failure or damage mechanism was generally observed during and after pull-out tests and in shear strength tests and that the anchor systems fail prior to the failure in the existing primary structural system. Furthermore, 3D finite element model for the anchor systems was created by ABAQUS to validate the experimental results using numerical analysis. It is shown that the formulated finite element model can be used to closely predict the load–displacement relationships as observed in the experimental tests. Further, we also propose a criterion for evaluating limit states to enable reliable design of the anchor systems using probabilistic fragility methodologies.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Structural Response to Dynamic Loads · Geotechnical Engineering and Underground Structures

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (21)

Show source-provided references
1. Cook RA, Kunz J, Fuchs W. Adhesive anchor under tensile loading. ACI Journal, Jan–Feb; 1998. pp. 9–25.
2. Factors affecting bond strength of adhesive anchors
3. The experimental investigation of a crack’s influence on the concrete breakout strength of a cast-in-place anchor10.1016/j.nucengdes.2005.09.018 ↗
4. Comite Euro-International du Beton (CEB). Task Group VI/5. Fastenings to concrete and masonry structures. London, UK: ThomasTelford Services Ltd.; 1994. p. 249.
5. ACI Committe 349. Code Requirement for nuclear safety related concrete structures and commentary. American Concrete Institute; 2011.
6. ACI Committee 355 Report. Evaluating the performance of post-installed mechanical anchors in concrete. ACI, Farmington Hills, Michigan; 2001.
7. Jensen BChr, Bræstrup MW. Lok-test determine the compressive strength of concrete. Nor-disk Betong, #2, 1976, Stockholm, Sweden; 1976.
8. ACI Committe 446. Fracture mechanics of concrete. American Concrete Institute; 2011.
9. Concrete capacity design (CCD) approach for fasteing to concrete
10. ABAQUS. Theory and user’s manual. Hibbitt, Karlsson, and Sorensen Inc., Pawtucket, Rhode Island, USA; 2011.
11. Hwang Y. A study on the fracture resistance characteristics of post-installed anchor. Seoul National University of Science and Technology Structural, engineering; 2011.
12. Prediction of load-carrying capacity of adhesive anchors by soft computing techniques10.1617/s11527-007-9265-6 ↗
13. A plastic-damage model for concrete10.1016/0020-7683(89)90050-4 ↗
14. Plastic-damage model for cyclic loading of concrete structures
15. Nonlinear finite element analysis of reinforced concrete columns
16. A concrete model for analysis of concrete structure with confinement
17. Seismic resistance of RC bent caps in elevated mass transit structures10.1193/1.3533471 ↗
18. Kwon · 1999
19. Gere J, Goodno B. Mechanics of materials. 7th Edition. 2009.
20. Developing fragility functions for building components for ATC-58
21. Dow J. Testing and analysis of iron and plastic T-joint in sprinkler systems. NEESR-GC: Simulation of the Seismic Performance of Nonstructural Systems; 2010 .