On the dispersion of data collected by in situ diagnostic of the existing concrete
Source abstract
Abstract
Abstract The compressive strength of in-place concrete is a crucial mechanical parameter which influences the performance level and the safety assessment of existing RC structures both under seismic loads and under dead loads. Italian NTC and Eurocode 8 [1] , [2] have established that the fundamental basis of the safety assessment is the “Knowledge Level (KL)”, which shall be defined according to the procedures adopted for in situ inspection and materials testing (destructive and non-destructive). Within this framework – in the case of RC constructions – a major requirement is the explicit identification of the reference values for the strength of in situ concrete. The afore mentioned building codes, however, do not include any consideration about the uncertainty level affecting the results of in situ tests, which can indeed invalidate the reliability of the mechanical parameters. This problem is instead well addressed by FEMA 356 [3] , which prescribes a limit value (14%) to the statistical dispersion of the measures performed on a set of concrete specimens. In this paper, after presenting and discussing a procedure applied for processing experimental data provided by in situ tests in a number of real case studies (school buildings in the Province of Foggia, Italy), the attention will be focused on the problem of the data scattering in the case of in situ concrete strength. It is shown that the variance is a crucial parameter, which should always be considered when performing the safety assessment, even if FEMA requirements, in this respect, are too much restrictive.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Structural Health Monitoring Techniques · Seismic Performance and Analysis · Structural Behavior of Reinforced Concrete
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (43)
Show source-provided references
1. DM 14/01/2008. Norme Tecniche per le Costruzioni – NTC2008. G.U. n. 29-2008: Roma; Italy [in Italian].
2. CEN. Eurocode 8. Design of structures for earthquake resistance. Part 3: assessment and retrofitting of buildings. European Committee for Standardization Brussels: Belgium; 2005.
3. Federal Emergency Management Agency. Prestandard for the seismic rehabilitation of buildings. FEMA 356. Reston. Va; 2000.
4. Circolare 2 febbraio 2009. n. 617 Approvata dal consiglio superiore dei Lavori Pubblici. Istruzioni per l’applicazione delle “Nuove norme tecniche per le costruzioni” di cui al decreto ministeriale 14 gennaio; 2008–2009 [in Italian].
5. CEN. Eurocode 2. Design of concrete structures. Part 1–1: General rules and rules for buildings. European Committee for Standardization, Brussels, Belgium; 2005.
6. Contract strength requirements – cores vs in situ evaluation
7. Determination of concrete quality in a structure by combination of destructive and non-destructive methods10.1007/BF02472458 ↗
8. Concrete strength by combined nondestructive methods Simply and reliably predicted10.1016/S0008-8846(00)00226-X ↗
9. Malhotra VM. Testing hardened concrete: non-destructive methods. ACI monograph no. 9. Detroit (US); 1976.
10. PCM – presidenza del consiglio dei ministri. Ordinanza N. 3274 – 20/03/2003. Allegato 2 – norme tecniche per il progetto. la valutazione e l’adeguamento degli edifici; 2003 [in Italian].
11. Raffaele D, Mezzina M, Tosto A. Overview on the regional scale analysis of school building in Puglia (Italy). In: Papadrakakis M, Papadopoulos V, Plevris V, editors. COMPDYN 2013–4th ECCOMAS Thematic Conference on Computational Methods in Structural Dynamics and Earthquake Engineering, Kos Island (Greece), June 12–14; 2013.10.7712/120113.4801.C1239 ↗
12. Raffaele D, Porco F, Fiore A, Uva G. Simplified vulnerability assessment of RC circular piers in multi-span-simply-supported bridges. Structure and Infrastructure Engineering; 2013, doi:10.1080/15732479.2013.772642.10.1080/15732479.2013.772642 ↗
13. UNI EN 12504–1. Testing concrete in structures – cored specimens – taking, examining and testing in compression. Unification National Institute; 2009.
14. UNI EN 12390–1. Testing hardened concrete – shape, dimensions and other requirements for specimens and moulds. Unification National Institute; 2009.
15. UNI EN 12390–3. Testing hardened concrete – compressive strength of test specimens. Unification National Institute; 2009.
16. ACI 214.4R-03 · 2003
17. ASTM Committee C-9. Standard test method for obtaining and testing drilled cores and sawed beams of concrete (ASTM C42–90). Annual book of ASTM standards. vol. 04.02. American Society for Testing and materials. Philadelphia (USA).
18. British Standard n.1881. PT.4. Methods of testing concrete for strength. British Standard Institution. Londra (UK); 1983.
19. Newman K, Lachance L. The testing of brittle materials under uniform uniaxial compressive stresses. In: Proceedings. American Society for Testing and materials; 1964; 64:1044–67.
20. Effect of length to diameter ratio of specimen on the apparent compressive strength of concrete
21. Effect of core diameter on concrete core strengths
22. Effect of core diameter on measured concrete strength
23. Lewis RK. Effect of core diameter on the observed strength of concrete cores. Commowealth Scientific and Industrial Research Organization Division of Building, Research report no. 50. Melbourne (Australia); 1976.
24. Core and cylinder strengths of natural and lightweight concrete
25. Effects of embedded reinforcement on the measured strength of concrete cylinders10.1680/macr.1989.41.146.11 ↗
26. FEMA 274. NEHRP commentary on the guidelines for the seismic rehabilitation of buildings, Federal Emergency Management Agency. Washington: DC (USA); 1997.
27. Concrete strength in structures
28. Concrete core strength – the effect of length to diameter ratio10.1520/JTE11631J ↗
29. Proposal of a methodology of in situ concrete tests and improving the estimate of the compressive strength10.1016/j.conbuildmat.2012.08.025 ↗
30. Concrete Society. Concrete core testing for strength. Concrete Society. Technical report n. 11. Londra (UK); 1987.
31. British standard n. 1881. Part 120. Method for determination of compressive strength of concrete cores. BSI (UK); 1983.
32. Effect of core length to diameter ratio on concrete core strength
33. Effect of moisture condition on concrete core strengths
34. Variation of in-place concrete strength
35. Study on the introduction into Italy on the combined non-destructive method for the determination of in situ strength
36. MacLeod G. An assessment of two non-destructive techniques as a means of examining the quality and variability of concrete in structures. Rep. C1/sfB/ Eg/(A7q)UDC 666.972.017.620 179.142.454. Cement and Concrete Association. London (UK); 1971.
37. Wiebenga JG. A comparison between various combined nondestructive methods to derive the compressive strength of concrete. Rep kB1-68- 61/1418. Inst TNO Veor Bouwmaterialen en Bouwconstructies. Delft: Netherland; 1968.
38. The use of combined non-destructive testing methods to determine the compressive strength of concrete
39. Pascale G, Di Leo A, Carli R. Evaluation of actual compressive strength concrete by NDT. In: Proceedings of 15th World Conference on non-destructive testing, Rome, Italy; 2005.
40. RILEM NDT 4. Recommendation for in situ concrete strength determination by non destructive combined methods. Compendium of RILEM Technical Recommendations. E&FN Spon. London (UK); 1993.
41. D.M. LL. PP. 30/5/1972. Norme tecniche alle quali devono uniformarsi le costruzioni in conglomerato cementizio. Normale e precompresso. ed a struttura metallica. G.U. n. 190 del 22/7/1972; Roma: Italy [in Italian].
42. Porco F, Uva G. Assessment of the reliability of structural concretes during execution phases. In: Papadrakakis M, Papadopoulos V, Plevris V, editors. COMPDYN 2013–4th ECCOMAS Thematic Conference on Computational Methods in Structural Dynamics and Earthquake Engineering, Kos Island, Greece. June 12–14; 2013.10.7712/120113.4782.C1237 ↗
43. Soniscope tests concrete structures