Abstract In order to increase the strengthening efficiency, a proposal for strengthening wood beams with hybrid fiber reinforced polymer (HFRP) is made. Carbon fiber (CF), glass fiber (GF) and high-strength glass fiber (SGF) were chosen as strengthening materials. CF strengthening beams, SCF strengthening beams, hybrid CF/GF strengthening beams, and hybrid CF/SGF strengthening beams were produced. A flexural experimental study including 12 strengthened beams and 3 control wood beams was carried out. The failure modes and failure mechanisms of the FRP and HFRP strengthened beams were investigated. The load–displacement characteristics, ultimate moment capacity and ductility of the different strengthened beams were discussed. The test results show that, compared with singly CF or SGF strengthening, HFRP strengthening may significantly increase the ductility of the strengthened wood beams under the premise of increasing moment capacity greatly at a lower cost. A calculation model for predicting ultimate moment capacity of wood beams strengthened with HFRP was put forward. The calculation results show a basic agreement with the tested values.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Wood Treatment and Properties · Innovative concrete reinforcement materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Reinforced wood laminated beams
2. Laminated wood beams reinforced with steel strips
3. Steel-reinforced wood beam design
4. Steel-reinforced glued laminated timber10.1061/(ASCE)0733-9445(1989)115:2(433) ↗
5. Wood beams prestressed with bonded tension elements
6. Ultimate strength design of reinforced timber: state of the art
7. Ultimate strength design of reinforced timber: moment-rotation characteristics
8. Ultimate strength design of reinforced timber: evaluation and design parameters
9. Ultimate strength design of reinforced timber: biaxial stress failure criteria
10. Bridge repair with high performance composite materials
11. Shear reinforcement of wood using FRP materials10.1061/(ASCE)0899-1561(1997)9:2(65) ↗
12. Triantafillou TC, Plevris N. Post-strengthening of r/c beams with epoxy-bonded fiber-composite materials. In: Proceedings of ASCE specialty conference on advanced composites for Civil Eng Struct. ASCE; 1991, p. 245–6.
13. Kropf FW, Meierhofer U. Strengthening, retrofitting and upgrading of timber structures with high-strength fibers, SEI 3/2000.10.2749/101686600780481536 ↗
14. Gentile C, Svecova D, Saltzbenbrg W, Rizkalla SH. Flexural strengthening of timber beams using GFRP. In: Third international conference in advanced composites materials in bridge and structures, proceedings, Ottawa, Canada; August 15–18 2000.
15. A method for flexural reinforcement of old wood beams with CFRP materials10.1016/j.compositesb.2004.04.013 ↗
16. Study on flexural behavior of timber beams strengthened with FRP
17. Enhancement of the flexural performance of retrofitted wood beams using CFRP composite sheets10.1016/j.conbuildmat.2007.11.005 ↗
18. Strengthening techniques tested on masonry structures struck by the Umbrian-Marche earthquake of 1997–199810.1016/S0950-0618(02)00014-4 ↗
19. Hybrid composites made of carbon and glass woven fabrics under quasi-static loading10.1016/j.matdes.2011.03.003 ↗
20. Qiao RS. Micro mechanical properties of composites. Xian, China: Northwest University of Technology Press; 1997. p. 117–23 [in Chinese].
21. Chinese Forestry standard LY/T1069. Technology rules of air drying sawn timber; 2012 [in Chinese].
22. The National Standard of the People’s Republic of China GB/T 1931. Method for determination of the moisture content of wood; 2009 [in Chinese].
23. ISO 3130. Wood – test methods. Determination of moisture content for physical and mechanical tests; 1975.
24. Adhesive system for structural connections in timber10.1016/S0143-7496(00)00049-X ↗
25. Interface shear stress: a new design criterion for plate debonding10.1061/(ASCE)1090-0268(2001)5:1(35) ↗
26. The National Standard of the People’s Republic of China GB/T 50329-2002. Standard for methods testing of timber structures. Standards Press of China, Beijing, China: General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China; 2002 [in Chinese].
27. ASTM D198-99. Standard test methods of static tests of lumber in structural sizes; 1999.
28. Bazan IM. Ultimate bending strength of timber beams. PhD Thesis. Nova Scotia Technical College, Halifax, NS, Canada; 1980.
29. Boding J, Jayne BA. Mechanics of wood and wood composites. New York: Van Nostrand Reinhold; 1982. Forest Products Laboratory. Wood handbook – wood as an engineering material. Gen Tech Rep FPL-GTR-113. Madison (WI): US Department of Agriculture, Forest Service; 1999.