journal article·2015-11

Experimental characterization and performance evaluation of geothermal grouting materials subjected to heating–cooling cycles

I. Indacoechea-Vega, P. Pascual-Muñoz, D. Castro-Fresno, M.A. Calzada-Pérez

Publisher page

Abstract

In recent years, the increasing rise in environmental awareness among energy consumers has led to an increasing use of renewable energies such as the geothermal energy. An important role in the efficient exploitation of the geothermal resource is played by the grouting material placed in the borehole between the pipes and the ground. Actually, the use of proper grouts is essential to provide an effective heat transfer between the ground and the heat carrier fluid in the pipes, and also to comply with the mechanical and environmental demands. However, when it comes to the construction of the GHP installations, the grout is especially required to be easy to work with (workable) and for this reason more water than required is sometimes added. In order to assess the suitability of grouting materials with significant water/solid ratios, the thermal conductivity, mechanical strength and permeability of five different grouts and grout–pipe specimens were measured for their laboratory characterization. In addition, the grouts were subjected to heating and cooling cycles to evaluate their durability with time in terms of the potential degradation of the materials and the loss of quality of the grout–pipe interface. According to the results obtained, the grouts here tested are appropriate for most of the geothermal heat pump installations, especially for those with low to medium ground thermal properties.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Geothermal Energy Systems and Applications · Geotechnical Engineering and Analysis · Climate change and permafrost

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Energy and environment: applications and sustainable development10.9734/BJECC/2011/480 ↗
2. Directorate-General for the Environment, European Commission, Attitudes of European citizens towards the environment, Special Eurobarometer 365, 2011.
3. Evaluation of heat exchange rate of GHE in geothermal heat pump systems10.1016/j.renene.2009.04.009 ↗
4. Materials characterization of superplasticized cement-sand grout10.1016/S0008-8846(00)00275-1 ↗
5. C.P. Redmund, J.T. Lund. Thermal enhancement of bentonite grouts for vertical GSHP systems. American Society of Mechanical Engineers, Advanced Energy Systems Division, 1993, AES 29, pp. 95–106.
6. Allan · 1996
7. Borehole grouting: field studies and thermal performance testing
8. Characteristics of thermally-enhanced bentonite grouts for geothermal heat exchanger in South Korea10.1007/s11431-009-0413-9 ↗
9. Enhancement of geothermal borehole heat exchangers performances by improvement of bentonite grouts conductivity10.1016/j.applthermaleng.2011.09.017 ↗
10. S. Erol, B. François, Thermal, hydraulic and mechanical performances of enhanced grouting materials for borehole heat exchanger, Coupled Phenomena in Environmental Geotechnics – Proceedings of the International Symposium, ISSMGE TC 215, 2013, pp. 491–499.10.1201/b15004-64 ↗
11. Efficiency of various grouting materials for borehole heat exchangers10.1016/j.applthermaleng.2014.05.034 ↗
12. M.L. Allan, Thermal conductivity of cementitious grouts for geothermal heat pumps, Progress Report FY 1997, Department of Applied Science, Brookhaven National Laboratory, New York, 1997.10.2172/573177 ↗
13. M.L. Allan, A.J. Philippacopoulos, Thermally conductive cementitious grouts for geothermal heat pumps, Progress Report FY 1998, Department of Applied Science, Brookhaven National Laboratory, New York, 1998.10.2172/307835 ↗
14. M.L. Allan, A.J. Philippacopoulos, Properties and performance of cement-based grouts for geothermal heat pump applications, Final Report FY 1999, Department of Applied Science, Brookhaven National Laboratory, New York, 1999.10.2172/751116 ↗
15. Thermal conductivity of cementitious grouts and impact on heat exchanger length design for ground source heat pumps10.1080/10789669.1999.10391226 ↗
16. Ground water protection issues with geothermal heat pumps
17. M.L. Allan, A.J. Philippacopoulos, Performance characteristics and modelling of cementitious grouts for geothermal heat pumps, Proceedings World Geothermal Congress 2000, Kyushu – Tohoku, Japan.
18. Influence of debonding in ground heat exchangers used with geothermal heat pumps10.1016/S0375-6505(01)00011-6 ↗
19. Strength and permeability of steel fibre reinforced grouts10.1016/j.conbuildmat.2010.02.011 ↗
20. Study of different grouting materials used in vertical geothermal closed-loop heat exchangers10.1016/j.applthermaleng.2012.05.029 ↗
21. Applicability of cement-based grout for ground heat exchanger considering heating-cooling cycles10.1007/s11431-011-4388-y ↗
22. UNE-EN 1015-6, Methods of tests for mortar for masonry, Part 6: determination of bulk density of fresh mortar, 1999.
23. UNE-EN 1015-10:2000/A1, Methods of tests for mortar for masonry. Part 10: determination of dry bulk density of hardened mortar, 2007.
24. ASTM D6910/D6910M – 09, Standard Test Method for Marsh Funnel Viscosity of Clay Construction Slurries, 2009.
25. ASTM C940-10a, Standard Test Method for Expansion and Bleeding of Freshly Mixed Grouts for Preplaced-Aggregate Concrete in the Laboratory, 2010.
26. ASTM D5334-08, Standard Test Method for Determination of Thermal Conductivity of Soil and Soft Rock by Thermal Needle Probe Procedure, 2008.
27. UNE-EN 1015-11:2000/A1, Methods of test for mortar for masonry – Part 11: determination of flexural and compressive strength of hardened mortar, 2007.