journal article·2011-05

Behaviour of joints with bonded-in steel bars loaded parallel to the grain of timber elements

David Yeboah, Su Taylor, Danny McPolin, Raymond Gilfillan, Stephen Gilbert

Publisher page

Abstract

Abstract This paper presents an experimental programme conducted to investigate the structural capacity of bonded-in steel bars loaded parallel to the grain in standard straight elements of natural timber. Tensile pull-out tests were conducted to examine the effect of bar diameter, bonded length and bar type (deformed and threaded steel bars) on the structural capacity of the connection. Pull-out tests on timber blocks in which the bars were deliberately misaligned in the holes were also tested to account for the fact that in real situations bars may not be perfectly centralised in the holes. The pull-out test results showed that bar diameter, bonded length and bar type considerably affected the structural capacities of the bonded-in steel joints. The results were compared with some established design equations.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Wood Treatment and Properties · Structural Load-Bearing Analysis · Civil and Structural Engineering Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Batchelar ML, Mcintosh KA. Structural joints in glulam. In: Proceedings of the 5th world conference in timber engineering, Montreux; 1988. p. 289–96.
2. Bengtsson C, Johansson CJ. GIROD-Glued in rods for timber structures. SP Report 2002:26. SP Swedish National Testing and Research Institute; 2001.
3. Blass HJ, Laskewitz B. Effect of spacing and edge distance on the axial strength of glued-in rods. In: Proceedings CIB-W18A, Graz, Austria; 1999.
4. Pull-out behaviour of steel rods bonded into timber
5. Ansell MP, Harvey K. Improved timber connections using bonded-in GFRP rods. In: WCTE 2000 World Conf Timber Eng; 2000.
6. Glued-in rods for timber structures – a 3D model and finite element parameter studies
7. Resin repairs in timber structures10.1016/S0143-7496(97)00060-2 ↗
8. Broughton · 2001 · 21
9. Resin-injected dowel joints in glulam and structural timber composites10.1016/S0950-0618(01)00002-2 ↗
10. Experimental tests on glued joints under axial forces and bending moments
11. Harvey K, Ansell MP, Mettem RJ, Bainbridge RJ, Alexandre N. Bonded-in protrusions for moment-resisting timber connections. In: Proceedings of the international council for research and innovation in building. CIB-W18/33-7-11; 2000.
12. Madhoushi M, Ansell MP. Flexural fatigue of beam to beam connections using glued-in GFRP rods. In: 8th World Conf Timber Eng 2004.
13. Yeboah D, Gilbert S, Gilfillan R. Behaviour of moment-resisting timber joints using bonded steel rods. In: 11th international conference on non-conventional materials for sustainable and affordable construction. Bath, UK: University of Bath; September, 6th–9th, 2009.
14. Broughton · 2001 · 15
15. Bernasconi A. Behaviour of axially loaded glued-in rods – requirements and resistance, especially for spruce timber perpendicular to the grain direction. CIB-W18, Timber Struct, Italy; 2001.
16. Ranta-Maunus · 1994
17. ENV 1995-2:1997 – Eurocode 5. Design of timber structures – part 2: bridges.
18. Riberholt H. Glued bolts in glulam-proposals for CIB code. International council for building research studies and documentation working commission CIB-W18. Timber Structures Meeting Twenty-one, Vancouver, Canada; 1988.
19. Gardelle V, Morlier P. Geometric parameters which affect the short term resistance of an axially loaded glued-in rod. Mater Struct 40. p. 127–38.10.1617/s11527-006-9155-3 ↗
20. Broughton JG, Hutchinson AR. Pull-out behaviour of reinforcement bonded into timber. In: Proceedings structural adhesives in engineering V, Inst. of Mater, 5th int conf., Bristol, UK; 1998.
21. Buchanan AH, Moss P. Design of epoxied steel rods in glulam timber. In: Proceedings of pacific timber engineering conference, vol. 3, No. 212. Rotorua; 1999. p. 286–93.
22. Buchanan · 2002
23. Structural adhesive joints including glued-in bolts
24. Pull-out strength of axially loaded steel rods bonded in glulam parallel to the grain10.1617/s11527-006-9111-2 ↗
25. Feligioni · 2003 · 61
26. Deng JX, Moss PJ, Buchanan AH. Glued bolts in glulam – An analysis of stress distribution. In: World conference on timber engineering, vol. 2. Montreax, Switzerland; 1998. p. 209.
27. Tomasi · 2004