journal article·2017-06

Experimental results on the retrofitting of hollow brick masonry walls with reinforced high performance mortar coatings

F. Messali, G. Metelli, G. Plizzari

Publisher page

Abstract

Abstract Many masonry buildings in Europe were built after the Second World War during a booming economy when seismic risk was not properly considered and, as a consequence, seismic codes were not available yet. Several of these buildings are quite small since they are used by one or two families. Because of the huge developments in the knowledge on seismic actions, there is now a major concern for the vulnerability of these buildings under possible earthquakes. The present work focuses on seismic strengthening of a masonry typology widely used for social housing. It is based on hollow masonry bricks with horizontal holes and poor cementitious mortar. Results of quasi-static cyclic tests carried out on full-scale unreinforced masonry walls with different geometries, representing either a shear wall or a pier-spandrel assembly, are presented. The specimens were repaired or strengthened with a thin layer of high-performance mortar reinforced with light steel-mesh. The test results show the effectiveness of the proposed technique since it provides a remarkable enhancement of both lateral strength and displacement capacity.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Masonry and Concrete Structural Analysis · Building materials and conservation · Hygrothermal properties of building materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (40)

Show source-provided references
1. Learning from construction failures due to the 2009 L’Aquila, Italy, Earthquake10.1061/(ASCE)CF.1943-5509.0000122 ↗
2. Performance of masonry buildings during the Emilia 2012 earthquake10.1007/s10518-013-9496-6 ↗
3. Tomazevic · 1994
4. Wooden roof box structure for the anti-seismic strengthening of historic buildings10.1080/15583050802063733 ↗
5. In-plane stiffening techniques with nail plates or CFRP strips for timber floors in historical masonry buildings10.1016/j.conbuildmat.2014.02.010 ↗
6. Behavior of concrete hollow-block masonry prisms under axial compression10.1061/(ASCE)0733-9445(1992)118:7(1751) ↗
7. Vertically perforated clay brick masonry for loadbearing and non-loadbearing masonry walls10.1016/j.conbuildmat.2010.04.010 ↗
8. N. Canal, Resistenza meccanica di blocchi forati a fori orizzontali, Consorzio Poroton Italia news, 33, 2006 (in Italian).
9. M. ElGawady, P. Lestuzzi and M. Badoux, A review of conventional seismic retrofitting techniques for URM, in: 13th International Brick and Block Masonry Conference, 2004, pp. 1–10.
10. Shear behavior of masonry panels strengthened by FRP laminates10.1016/S0950-0618(02)00043-0 ↗
11. Foster · 2005 · 230
12. Strengthening of masonry structures using epoxy-bonded FRP laminates10.1061/(ASCE)1090-0268(1998)2:2(96) ↗
13. Characteristics of CFRP retrofitted hollow brick infill walls of reinforced concrete frames10.1016/j.conbuildmat.2011.04.036 ↗
14. Repair and investigation techniques for stone masonry walls10.1016/S0950-0618(97)00031-7 ↗
15. Mechanical behaviour of historic masonry structures strengthened by bed joints structural repointing10.1016/j.conbuildmat.2004.04.036 ↗
16. R. Amiraslanzadeh, T. Ikemoto, M. Miyajima and A. Fallahi, A Comparative study on seismic retrofitting methods for unreinforced masonry brick walls, in: 15th Conference Earthquake Engineering, WCEE Lisboa, 2012.
17. Improving shear strength of unreinforced masonry walls by nano-reinforced fibrous mortar coating10.1617/s11527-014-0337-0 ↗
18. L. Kahn, Shotcrete strengthening of brick masonry walls. Concr. Int. Des. Constr., 6(7), 34–40.
19. D.Y.P. Hutchison, G. McKenzie, Laboratory testing of a variety of strengthening solutions for brick masonry wall panels, in: 8th WCEE, USA, pp. 575–582, 1984.
20. Tomazevic · 1999
21. Seismic behavior of unreinforced and confined brick masonry walls before and after ferrocement overlay retrofitting10.1080/15583058.2011.599916 ↗
22. Strengthening of stone masonry walls with composite reinforced coatings10.1007/s10518-014-9697-7 ↗
23. Diagonal compression tests on masonry walls strengthened with a GFRP mesh reinforced mortar coating10.1007/s10518-014-9684-z ↗
24. Experimental and analytical study to evaluate the effectiveness of an in-plane reinforcement for masonry walls using GFRP meshes10.1016/j.conbuildmat.2015.04.014 ↗
25. Textile-reinforced mortar (TRM) versus FRP as strengthening material of URM walls: in-plane cyclic loading10.1617/s11527-006-9207-8 ↗
26. Textile reinforced mortar (TRM) versus FRP as strengthening material of URM walls: out-of-plane cyclic loading10.1617/s11527-007-9226-0 ↗
27. European Committee for Standardization (CEN), EN 772-1: Methods of test for masonry units. Determination of compressive strength, Brussels, 2011.
28. UNI 9730-3. Prove su elementi di laterizio per solai. Ente nazionale italiano di unificazione, Roma, 1990 (in Italian).
29. A penetration test to study the mechanical response of mortar in ancient masonry buildings10.1007/BF02480678 ↗
30. European Committee for Standardization (CEN), EN 1015-11: Methods of test for mortar for masonry–Part 11: Determination of flexural and compressive strength of hardened mortar, Brussels, 1999.
31. European Committee for Standardization (CEN), EN 1052-1: Methods of Test for Masonry-Part1. Determination of Compressive Strength, Brussels, 2001.
32. Retrofitting of Hollow Brick Masonry Walls With High Performance Mortar Coatings Reinforced With Steel Mesh: Experimental Studies and Numerical Analysis with a Semi-lumped Approach
33. European Committee for Standardization (CEN), EN 1052-1: Methods of Test for Masonry-Part1. Determination of Compressive Strength, Brussels, 2001.
34. European Committee for Standardization (CEN), EN 12390-13. Testing hardened concrete – part 13: Determination of secant modulus of elasticity in compression, Brussels, 2013.
35. International Standards Organization. EN ISO 15630-1: Steel for the reinforcement and prestressing of concrete – Test methods – Part 1: Reinforcing bars, wire rod and wire, Geneve, 2010.
36. Static cyclic response of masonry walls retrofitted withfiber-reinforced polymers10.1061/(ASCE)1090-0268(2007)11:1(50) ↗
37. Strengthening of stone masonry walls with composite reinforced coatings10.1007/s10518-014-9697-7 ↗
38. Experimental assessment of the in-plane lateral capacity of autoclaved aerated concrete (AAC) masonry walls with flat-truss bed-joint reinforcement10.1016/j.conbuildmat.2015.02.057 ↗
39. Rots JG. (Ed.). Structural masonry: an experimental/numerical basis for practical design rules. 1997, AA Balkema.
40. Circolare 2 Febbraio 2009 n.617. Instructions for the application of the new technical code for structures G.U. n.47, February 26, 2009, Supplemento Ordinario n.27, Rome, 434 pp, (In Italian).