journal article·2014-06

Static analysis of adhesively bonded anchorages for CFRP tendons

F. Puigvert, A.D. Crocombe, L. Gil

Publisher page

Abstract

Abstract In pre-stressed concrete structures, consideration is being given to replacing the steel tendons with CFRP rods. One of the challenges associated with this is to develop a suitable anchorage for the CFRP rods. A bonded anchorage was investigated, where the CFRP is potted in a steel tube using epoxy adhesive. Experimental static tests of different configurations were undertaken with failure occurring in the bond. A set of numerical simulations were carried out with different adhesive material models to investigate the static response of the bonded anchorage and its failure mechanism. The adhesive was modelled with linear elastic properties, von Mises plasticity, Drucker–Prager plasticity and progressive damage. A cohesive zone model with progressive damage in the bonded joint was found to be in reasonable agreement with the experimentally recorded data. Also, an analytical formulation was developed (and validated) in order to provide an approximate distribution of shear stress in the bonded joint for circular anchors for adhesives with mainly elastic behaviour.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Structural Behavior of Reinforced Concrete · Mechanical Behavior of Composites · Concrete Corrosion and Durability

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (24)

Show source-provided references
1. 440R-07 A. Report on Fiber-Reinforced Polymer (FRP) Reinforcement for concrete structures. ACI, 2007. p. 1–104.
2. Durability of concrete beams prestressed with CFRP
3. FRP tendon anchorage in post-tensioned concrete structures
4. Benatar · 1997
5. Jones · 1999
6. Performance of FRP tendon anchor systems for prestessing concrete structures10.15554/pcij.01011996.34.44 ↗
7. Mechanical anchorage of FRP tendons – a literature review10.1016/j.conbuildmat.2011.11.049 ↗
8. New designs of adhesive joints for thick composite laminates10.1016/S0266-3538(00)00157-3 ↗
9. Anchorage of carbon fiber reinforced polymer (CFRP) tendons using cold-swaged sleeves10.15554/pcij.11012001.100.111 ↗
10. Die Niet kraftverteilung in zugbeanspruchten Nietverbindungen mit konstanten Laschen querschnitten
11. The stresses in cemented joint10.1115/1.4009336 ↗
12. Improved theoretical solutions for adhesive lap joints10.1016/S0020-7683(97)00097-8 ↗
13. Hart-Smith LJ. Adhesive-bonded single-lap joints. NASA Langley Contract Rep NASA CR-112236, January 1973. p. 116.
14. Analytical models of adhesively bonded joints—Part I: Literature survey10.1016/j.ijadhadh.2008.06.005 ↗
15. Analytical models of adhesively bonded joints—Part II: comparative study10.1016/j.ijadhadh.2008.06.007 ↗
16. Simple Lap Joint Geometry
17. Environmental Degredation
18. Fracture mechanics of single-fibre pull-out test10.1023/A:1018534323464 ↗
19. Factors which influence the reliability of the assessment of interfacial bonding in fibrous composites using the pull-out test10.1016/S0143-7496(00)00042-7 ↗
20. BASF Construction Chemicals BS. MBrace Primer – product, information, 2008.
21. 440.3R-04 A. Guide test methods for fiber-reinforced polymers (FRPs) for reinforcing or strengthening concrete structures. ACI, 2004. p. 1–40.
22. Puigvert · 2011
23. Measuring hydro-static dependent constitutive behaviour of adhesives using a bend specimen10.1080/00218469308044648 ↗
24. A unified approach for predicting the strength of cracked and non-cracked adhesive joints10.1080/00218469508014357 ↗