journal article·2014-03

Determination of shear strength of historic masonries by moderately destructive testing of masonry cores

Claudio Mazzotti, Enrico Sassoni, Giulia Pagliai

Publisher page

Abstract

Abstract To determine masonry shear strength, which is a fundamental parameter for evaluating the seismic vulnerability of existing masonry buildings, several experimental techniques can be adopted. A promising method is subjecting cores, easily core-drilled from masonry buildings, to splitting test with mortar layer rotation, so that in the centre of the mortar joint a mixed compression–shear stress state is present. To investigate the actual suitability of testing cores for determining masonry shear strength, in this study a systematic comparison between reference masonry panels, subjected to shear-compression test, and cores, subjected to splitting test with different mortar layer inclinations, was performed. Ten masonry panels were constructed using fired-clay solid bricks and a mixed lime-cement mortar with poor mechanical properties, with the aim of resembling materials used in historic buildings. After curing for 28 days, nine masonry panels were tested, compression stress being kept constant at a fixed value and shear stress being increased until failure. By plotting shear stress against compression stress and performing linear regression, the initial shear strength and the angle of internal friction of the masonry were obtained. The tenth masonry panel was core-drilled to obtain cylindrical cores (10 cm diameter, 25 cm length) with a central diametric mortar joint. The cores were then subjected to splitting test with mortar layer inclinations of 0°, 15°, 30°, 40°, 45° and 50° with respect to the horizontal. While cores tested at 15° and 30° exhibited a splitting failure mode, cores tested at higher mortar layer inclinations exhibited a sliding failure mode, which was considered as the most representative one for evaluating masonry shear resistance. By plotting the shear stress against the compression stress for cores tested at 40°, 45° and 50° and then performing a linear regression, the initial shear strength and the angle of internal friction were derived. As results found for reference masonry panels and for cylindrical cores exhibit very good agreement, the proposed methodology seems like a very promising technique, which has the advantage of requiring only moderately destructive samples that can be easily core-drilled from existing buildings.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Masonry and Concrete Structural Analysis · Building materials and conservation · Microbial Applications in Construction Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. The road map for seismic risk analysis in a mediterranean city10.1016/j.soildyn.2008.12.001 ↗
2. Comparative seismic vulnerability analysis on ten masonry towers in the coastal po valley in Italy10.1016/j.engstruct.2012.11.033 ↗
3. Simplified indexes for the seismic vulnerability of ancient masonry buildings10.1016/j.conbuildmat.2005.08.027 ↗
4. Seismic vulnerability of historical masonry buildings: a case study in Ferrara10.1016/j.engstruct.2007.11.006 ↗
5. Seismic vulnerability of monumental buildings10.1016/S0167-4730(01)00018-2 ↗
6. Investigation procedures for the diagnosis of historic masonries10.1016/S0950-0618(00)00018-0 ↗
7. Experimental study on the determination of strength of masonry walls10.1016/S0950-0618(03)00007-2 ↗
8. Experimental identification of a multi-span masonry bridge: the tanaro bridge10.1016/j.conbuildmat.2007.07.031 ↗
9. The use of small diameter cores for assessing the compressive strength of clay brick masonries10.1016/j.culher.2012.11.027 ↗
10. Sassoni E, Mazzotti C, Pagliai G, Comparison between experimental methods for evaluating the compressive strength of existing masonry buildings, submitted to Materials and Structures.
11. Eurocode 6, UNI ENV 1996-1-1, Design of masonry structures – Part 1-1: General rules for buildings – rules for reinforced and unreinforced masonry; 1998.
12. D.M. 14/01/2008 (Decreto del Ministero delle Infrastrutture 14 gennaio 2008), Approvazione delle nuove norme tecniche per le costruzioni; 2008 [in Italian].
13. Benedetti A, Pelà L, Aprile A. Masonry properties determination via splitting tests on cores with a rotated mortar layer. In: Proceedings of “8th international seminar on structural masonry”, Istanbul (Turkey); 5–7 November 2008.
14. Benedetti A, Pelà L. Experimental characterization of mortar by testing on small specimens. In: Proceedings of “15th international brick and block masonry conference”, Florianòpolis (Brazil); 13–16 May 2012.
15. Pelà L, Benedetti A, Marastoni D. Interpretation of experimental tests on small specimens of historical mortars. In: Proceedings of 8th international conference on structural analysis of historical construction, Wroclaw (Poland); 15–17 October 2012.
16. EN 1052-4, Methods of test for masonry – Part 4: determination of shear strength including damp proof course; 2001.
17. ASTM E519/519M-10, Standard test method for diagonal tension (shear) in masonry assemblages; 2010.
18. Shear strength of brick masonry walls assembled with different types of mortar10.1016/j.conbuildmat.2012.11.107 ↗
19. EN 1052-3, Methods of test for masonry – Part 3: determination of initial shear strength; 2007.
20. Effect of salt crystallization on the shear behaviour of masonry walls: an experimental study10.1016/j.conbuildmat.2012.07.086 ↗
21. ASTM C1531-09, Standard test method for in situ measurement of masonry mortar shear strength index; 2009.
22. Braga F, Dolce M, Masi A. Interpretazione statistica di prove sperimentali per l’accertamento della resistenza a taglio della muratura di edifici esistenti, 6° Convegno Nazionale “L’ingegneria sismica in Italia”; Perugia (Italy); 13–15 Ottobre 1993 [in Italian].
23. Filardi B, Liberatore D. Una nuova prova di carico per determinare la resistenza a taglio della muratura: modellazione e analisi parametrica, Atti del Convegno Nazionale “La meccanica della muratura tra teoria e progetto”, Messina (Italy); 18–20 Settembre 1996 [in Italian].
24. EN 998-2, Specification for mortar for masonry – Part 2: masonry mortar; 2010.
25. Augenti N. Il calcolo sismico degli edifici in muratura, UTET, Torino; 2004 [in Italian].
26. EN 772-1, Methods of test for masonry units - determination of compressive strength; 2002.
27. EN 1015-11, Methods of test for mortar for masonry – Part 11: determination of flexural and compressive strength of hardened mortar; 2007.