Quasi-static and high cycle fatigue strength of brick masonry
Source abstract
Abstract
Quasi-static and high cycle fatigue tests have been conducted on brick masonry test specimens under laboratory dry, wet and submerged test conditions. The relatively low compressive strengths of the bricks and mortar used to manufacture the test specimens were intended to be representative of the type of bricks and mortar likely to be encountered in relatively old masonry arch bridges. The quasi-static test results indicate that the compressive strength of brick masonry increases with an increase in the compressive strength of the mortar, and decreases with an increase in the degree of saturation. The compressive strength of brick masonry, based on assumed linear no tension stress distributions, increases with an increase in the load eccentricity or stress gradient. Approximately 20% of the apparent increase in compressive strength due to load eccentricity can be attributed to non-linear material behaviour, resulting in non-linear no tension stress distributions in the mortar joints. The high cycle fatigue tests on laboratory dry, wet and submerged test specimens indicate that the fatigue strength of brick masonry depends upon the induced stress range, the mean or maximum induced stress and the quasi-static compressive strength of the brick masonry under similar loading conditions. A lower bound fatigue strength curve for laboratory dry, wet and submerged brick masonry is proposed.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Masonry and Concrete Structural Analysis · Structural Health Monitoring Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (10)
Show source-provided references
1. BD 21/97 Design manual for roads and bridges: vol 3: sect 4: part 3: the assessment of highway bridges and structures, Department of Transport; 1997.
2. Service load response of masonry arch bridges10.1061/(ASCE)0733-9445(1998)124:1(17) ↗
3. BS 3921:1985. Clay bricks. British Standards Institution, London.
4. BS 5628:1992. Code of practice for use of masonry: Part 1: Structural use of unreinforced masonry. British Standards Institution, London.
5. Choo BS, Hogg V. Determination of the serviceability limit state for masonry arch bridges. Arch Bridges, Thomas Telford, London; 1995. p. 529–36.10.1680/ab.20481.0053 ↗
6. Clark GW. Bridge analysis testing and cost causation: serviceability of brick masonry. British Rail Research Report LR-CE5-151; 1994.
7. Stability strength elasticity and thrust lines in masonry arches
8. Hendry AW. Masonry properties for assessing arch bridges. TRRL Contractor Report 244, Department of Transport; 1990.
9. A review of UK masonry arch bridge assessment methods10.1680/istbu.1997.29801 ↗
10. Design rules for concentrated loads on masonry