Abstract
In recent years much experience has been gained with continuous acoustic monitoring of monostrands and stay cables. However, there is little knowledge with monitoring of post-tensioned bridges with bonded tendons. An acoustic monitoring system has been installed on a road bridge to evaluate its diagnostic performance. This bridge, the Ponte Moesa, is one of the first prestressed concrete bridges in Switzerland. Insufficient grouting and de-icing salts among other causes have led to deterioration and wire breaks. Blind tests have been conducted generating artificial wire breaks by means of electrolytic corrosion-cells. Additionally, several spontaneous wire breaks occurred. To evaluate the applicability of acoustic monitoring, the results were compared with those of a conventional invasive examination and those of potential mapping.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Concrete Corrosion and Durability · Geophysical Methods and Applications · Structural Health Monitoring Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (10)
Show source-provided references
1. Continuous acoustic monitoring of grouted post-tensioned concrete bridges
2. Monitoring prestressed structures
3. Elliott P, Tozser O. Long-term continuous acoustic monitoring of suspension, cable-stayed and post-tensioned bridges. In: Proceedings of international RILEM workshop on life prediction and aging management of concrete structures, Slovakia, Bratislava; 1999.
4. Maag W Zustandsbericht, Ponte Moesa Roveredo H, Rigendinger Mitarbeiter W. Maag Dipl. Bauingenieure ETH/SIA 7000 Chur, unpublished report, Chur, January 2001.
5. Tiefbauamt Graubünden, Ponte Moesa Roveredo. Dokumentation über die Vorspannarbeiten. Tiefbauamt Graubünden, unpublished report, Chur; 1952.
6. Tiefbauamt Graubünden. Ein Stethoskop für den Ponte Moesa in Roveredo. TBA-info, No. 58–6, Tiefbauamt Graubünden, Chur, June 2004.
7. Maag W Fotodokumentation, Ponte Moesa Roveredo H, Rigendinger Mitarbeiter W. Maag Dipl. Bauingenieure ETH/SIA 7000 Chur, unpublished report, Chur, Jan 2001.
8. Fricker S, Vogel T. Site installation and trials of the acoustic monitoring system SoundPrint. In: Proceedings of Second fib IABSE workshop on durability of post-tensioning tendons, Switzerland, ETH Zurich; 2004.
9. Cullington DW, MacNeil D, Paulson P, Elliott J. Continuous acoustic monitoring of grouted post-tensioned concrete bridges. In: Conference proceedings of international structural faults & repair-1999 8th international conference, London, England; 1999.
10. Schiegg Y. Potenzialmessungen Ponte Moesa Roveredo. Report number 04’120, Swiss association for corrosion-protection (SGK), unpublished report, Zürich, October 2004.